FREQUPS, FW-A Series (Part Numbers)

FREQUPS, FW-A Series

Standard model UPS which can protect the power supply for servers and factory automation equipment.
[Features]
· Apply the line interactive method.
· Support a wide range of input voltage.
· Lightning and surge protection circuit and noise filter are built-in.
· Removable wired remote controller is built-in as standard.
[Applications]
· Power supply for back up operation when having a power trouble.

FW-A Series Specifications

FREQUPS FW-A Series: related image

FW-A series appearance

FREQUPS FW-A Series: related image

FW-A series front dimensional outline drawing

FREQUPS FW-A Series: related image

FW-A series right side dimensional outline drawing

 

(Unit: mm)

 

FREQUPS FW-A Series: related image

Name of each part (back surface)

  • 1.DIP switch: sets various functions.
  • 2.RS-232C connector (D-sub 9-pin male): connect a communication cable when performing shutdown or when using FREQSHIP.
  • 3.OUTPUT1 output outlet (100 V 2 P 15 A with ground NEMA5-15R): connect load.
  • 4.Option board slot: slot for inserting option board.
  • 5.OUTPUT2 output outlet (100 V 2 P 15 A with ground NEMA5-15R): connect load.
  • 6.Ground screw (M4)
  • 7.Input circuit protector: trips when overcurrent occurs, and a button protrudes. Press protruding button to reset.
  • 8.Input plug (cable length: 2.5 m) (2 P 15 A with ground NEMA5-15P): single-phase plug with ground contact. Insert into commercial 100 V outlet.
  • 9.USB connector (Type B): connect a communication cable when performing shutdown or when using FREQSHIP.
FREQUPS FW-A Series: related image

Wired remote control specifications

Specifications

-FREQUPS
FW-A Series
ModelFW-A10H-1.0KFW-A10H-1.4K
Operation MethodLine interactive method
AC InputNumber Of Phases / LinesSingle-phase 2-line method (with earthing)
Connection Plug / Terminal Block2 P 15 A with earthing
NEMA 5-15P
Input Voltage Range81 V AC to 124 V AC±3 V AC (Note 1)
Frequency50 Hz / 60 Hz ±10%
Input Capacity1.1 kVA1.5 kVA
Input Power FactorDepends on connected load
BatteryTypeLead-acid battery with small control valve
Expected Life5 years (ambient temperature 20°C)
Power Interruption Backup Time5 minutes
(Rated load, initial characteristics, ambient temperature 25°C)
Charge Time5 hours or less (charging amount 90%)
AC OutputNumber Of Phases / LinesSingle-phase 2-line method (with earthing)
Voltage100 V ±5% (Note 2)
Frequency50 Hz / 60 Hz ±0.8% (Note 2)
Output Capacity1.0 kVA/700 W1.4 kVA / 1 kW
Output: 100 V Output2P 15A with earthing
NEMA 5-15R
6 (2 lines, 2 outputs / 4 outputs)
Output: Terminal Block-
Voltage WaveformSine wave (Note 2)
Backup Switch Time4 ms or less (high speed relay switching method) (Note 3)
Inverter Allowable Peak Current250% of rated current effective value (instantaneous value)
Voltage Waveform Distortion Factor-
Overload Protection110% 30 seconds / 140% 3 seconds (Note 4)
EnvironmentAmbient Temperature0 to 40°C (recommended value 20 to 30°C)
Relative Humidity25 to 85% (no condensation)
Startup MethodBattery startup
Cooling MethodSelf-coolingForced air cooling
(During rapid charging / backup operation)
Heat Generation Amount (During Rated Load)50 W70 W
External InterfaceRS-232C (D-Sub 9-Pin Male Connector)
USB (Type B)
External Signal-
Slot For Option Board
Noise45 dB or less (Front 1 m, A characteristics)
Paint ColorBlack
External ShapeW × H × D (mm)170 × 220 × 440
WeightApprox. 21 kgApprox. 26 kg
StandardUL Standard-
CE Mark (Self-Declaration)-
Compliance StandardVCCI class A
Notes*1: When AVR function operates continually, use the constant inverter power supply method.
Note 2: During backup operation.
* 3: Standard sensitivity (when shipping from factory)
*4: Value during backup operation state.
Cautions1) Do not connect a load using the half-wave rectification method.
2) When using a step-down transformer on the UPS primary side, please select this using the guideline of more than 1.5 times the UPS rated capacity.
Part Number
FW-A10H-0.7K
FW-A10H-1.0K
FW-A10H-1.4K
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSRated Output Current
(A)
Rated output capacity
(VA)
Dimension length
(mm)
Dimension width
(mm)
Dimension thickness
(mm)

MYR 5,653.56

1 Piece(s) 36 Day(s) or more -7700160140360

MYR 4,669.37

1 Piece(s) 13 Day(s) or more 6101000220170440

MYR 5,046.60

1 Piece(s) 9 Day(s) or more 6141400220170440

Loading...

  1. 1

Download(PDF)

  • ※MITSUBISHIWebサイトへリンクします。

Basic Information

Input Voltage(V) AC81 to 124 Output Voltage(V) AC100 Power Supply Method Line interactive
Battery type Lead Input source resultant pulse Single-Phase Number of output phases Single-Phase
Compensation time for power outage(Minute) 5 Specifications Tower

Additional Products in this Category