Finger lever valve, VHEF Series (Part Numbers)

Part Number

Configured Part Number is shown.

Part Number
VHEF-L-M52-E-G14
VHEF-L-M52-E-G18
VHEF-L-M52-M-G14
VHEF-L-M52-M-G18
VHEF-LT-M32-M-G14
VHEF-LT-M32-M-G18
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipPneumatic connection 1 Pneumatic connection 2 Pneumatic connection 3 Pneumatic connection 4 Pneumatic connection 5 Pneumatic working port Valve function Lap Nominal width
(mm)
Standard nominal flow rate
(l/min)
Manufacturer part # Weight
(g)

MYR 1,230.20

1 Piece(s) 9 Day(s) or more G1/4G1/4G1/4G1/4G1/4G1/45/2, monostableOverlap712004500004217

MYR 1,050.51

1 Piece(s) 21 Day(s) or more G1/8G1/8G1/8G1/8G1/8G1/85/2, monostableOverlap5.27504500005184

MYR 983.04

1 Piece(s) 9 Day(s) or more G1/4G1/4G1/4G1/4G1/4G1/45/2, monostableOverlap712004500000218

MYR 840.55

1 Piece(s) 9 Day(s) or more G1/8G1/8G1/8G1/8G1/8G1/85/2, monostableOverlap5.27504500001185

MYR 797.67

1 Piece(s) 9 Day(s) or more G1/4G1/4G1/4--G1/43/2, open/closed, monostableZero overlap68704500008150

MYR 683.04

1 Piece(s) 9 Day(s) or more G1/8G1/8G1/8--G1/83/2, open/closed, monostableZero overlap5.67504500009156

Loading...

  1. 1

Basic Information

Housing material Wrought aluminum alloy, anodized Seals material NBR Max. switching frequency(Hz) 0.5
Width(mm) 20 Flow direction Reversible Min. Operating pressure(bar) -0.95
Max. Operating pressure(bar) 10 Min. Temperature of medium(°C) -10 Max. Temperature of medium(°C) 60
Min. Ambient temperature(°C) -10 Max. Ambient temperature(°C) 60 Operating medium Compressed air as per ISO 8573-1:2010 [7:-:-]
Corrosion resistance class (CRC) 1 - Low corrosion stress Actuation type Manual Exhaust air function With flow control option
Explosion prevention and protection Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) Information on operating and pilot media Operation with oil lubrication possible (required for further use) LABS (PWIS) conformity VDMA24364-B1/B2-L
Mounting position Any Note on materials RoHS-compliant Sealing principle Soft
Type of control Direct