Smart Proximity Sensor [E2NC] (Part Numbers)

Smart Proximity Sensor [E2NC]

Click this image to zoom it.

Move the mouse over the image to zoom

A smart proximity sensor that makes it easy to set high-precision sensitivity.
[Features]
・ Sensor head variations that can be selected according to the intended use
·A flexible cable is used between the preamplifier of the sensor head and the amplifier
·With temperature characteristics of 0.08%/°C, the sensor is not easily affected by changes in ambient temperature
・ Micron accuracy can be detected and set easily and reliably (Teaching function)
・ You can check the detection margin (Digital display)
・ Supports high-precision positioning and discrimination inspection
·"FP (Fine Positioning) function" that maximizes the amount of change
・ Assortment of sensor communication unit types compatible with EtherCAT sensor communication unit / CC-Link sensor communication unit

PDF

Drawing

Sensor head

Smart proximity sensor [E2NC] sensor head external shape figure-1
Smart proximity sensor [E2NC] sensor head external shape figure-2
Smart proximity sensor [E2NC] sensor head external shape figure-3

Amplifier unit

Pre-Wired Type

Smart proximity sensor [E2NC] amplifier unit pre-wired type external shape figure

*1. Mounting metal fitting can also be used on surface B
*2. The cord diameter for ⌀A is as follows

Model E2NC-EA21⌀4.05 PinsConductor cross-sectional area: 0.2 mm2
Insulator diameter: 0.9 mm
Model E2NC-EA51
 

Reduced wiring connector type

Smart proximity sensor [E2NC] amplifier unit connector type for simplified wiring external shape figure

*1. Mounting metal fitting can also be used on surface B
*2. The cord diameter for ⌀A is as follows

E3X-CN12⌀2.6Simplex
E3X-CN22⌀4.02 contacts
E3X-CN113 contacts
Model E3X-CN214 contacts
 

Connector type for sensor communication unit

Smart proximity sensor [E2NC] amplifier unit, connector type for sensor communication unit, figure

Product Specification

Rating / Performance

Sensor head

ItemsType
Model E2NC
- EDR6-F
Model E2NC
- ED01 (-*)
Model E2NC
- ED02 (-*)
Model E2NC
- EM02 (-*)
Model E2NC
- EV05 (-*)
Model E2NC
- EM07M
(-*)
Model E2NC
- EM02H
⌀3 x 18 mm⌀5.4 x 18 mm⌀8 x 22 mmM10 x 22 mm30 x 14 x 4.8 mmM18 x 46.3 mmM12 × 22 mm
Sensing Distance0.6 mm1 mm2 mm2 mm5 mm7 mm2 mm
Detectable objectsFerromagnetic metal (for non-magnetic metals, the sensing distance decreases. See "Characteristic Data" → Digital Catalog page 7)
Standard detected object5 × 5 mm5 × 5 mm10 × 10 mm10 × 10 mm15 × 15 mm22 × 22 mm20 × 20 mm
Material: Steel (t = 3, S50C)
repeatability *11 μm1 μm2 μm2 μm2 μm5 μm2 μm
HysteresisVariable
Temperature characteristics
*2
Sensor head section0.3%/°C0.08%/°C0.08%/°C0.08%/°C0.04%/°C0.08%/°C0.2%/°C
Other than sensor head section0.08%/°C
Ambient temperature range
*3
When operating-10 to +60°C (no freezing or condensation)-10 to +200°C
(no freezing or condensation) *4
When storing-10 to +60℃
(no freezing or condensation)
-20 to +70°C (no freezing or condensation)
Ambient humidity rangeWhen operating/storing: 35 to 85% RH each (no condensation)
Insulation resistance50 MΩ or more (500 V DC insulation resistance tester)
Withstand voltage1,000 V AC 50/60 Hz for 1 min
Vibration (endurance)10 to 55 Hz, 1.5 mm double amplitude, 2 hours in each direction of X, Y, and Z
Shock (endurance)500 m/s2 in Each X, Y, Z Direction 3 times
Protective Structure
(Sensor head section)
IEC standard IP67IP60 *5
Mass (packed state) *6Approx. 120 g
MaterialSensor head sectionBrassSUSBrassBrassZincBrassBrass
Detecting surfaceHeat-resistant ABSBrass
PreamplifierPESPEEK
Connection method *7Connector connection (Standard/protective spiral tube type: standard cable length 2.6 m / Free-cut type: standard cable length 3.6 m)
AccessoryInstruction manual

*1. Repeatability: Value when the standard detected object is placed at 1/2 of the rated detection range.
*2. Temperature characteristics: These are the values when the standard detected object is placed at half the rated detection range.
*3. Even within the operating temperature range, please note that sudden increases or decreases in temperature may cause performance degradation.
*4. Sensor head only (preamplifier section: -10 to 60°C).
*5. This product is not water resistant and cannot be used in steam environments.
*6. Mass: The mass in the packaged state. With protective spiral tube, the mass increases by 90 g.
*7. The standard cable length includes both the preamplifier section and the connector section.

 

Amplifier unit

ItemsTypeHigh-functionFor sensor communication unit *1
NPN outputModel E2NC-EA21Model E2NC-EA7TWModel E2NC-EA7Model E2NC-EA10Model E2NC-EA0
PNP outputModel E2NC-EA51Model E2NC-EA9TWModel E2NC-EA9Model E2NC-EA40
Connection methodPre-wired (2 m)Connector for simplified wiringSensor communication
unit connector
pre-wired (2 m)
Sensor communication
Connector for unit
Input/outputOutput2 output1 output1 output *22 output *3
External input*41 input-1 input--
Power supply voltage10 to 30 V DC, including 10% ripple (pp)Refer to the specifications of the communication unit
Power consumption*5At power supply voltage 24 V
Normal mode: 1,080 mW or less (current consumption 45 mA or less), Eco function ON: 840 mW or less (current consumption 35 mA or less),
Eco function LO: 960 mW or less (current consumption 40 mA or less)
Control outputLoad power supply voltage: 30 V DC or less, open collector output type
Load current: 100 mA or less when connecting 1 to 3 units, 20 mA or less when connecting 4 or more units
Residual voltage when load current is less than 10 mA: 1 V or less
Load current 10 to 100 mA: 2 V or less
Off-state current: 0.1 mA or less
Please refer to the specifications of the communication unit.
Indicator light7-segment display (sub-digital display: green, main digital display: white)
Display direction: Normal / reverse display switchable
OUT indicator light (orange), NO/NC indicator light (orange), ST indicator light (blue)
OUT selection indicator light (orange) (2 output only)
Protection circuitPower supply reverse connection protection, output short circuit protection, output reverse connection protectionPower supply reverse connection protection,
output short circuit protection
Response timeFastest mode (SHS)Operation and recovery: 150 μs each
High-speed mode (HS)Operation and recovery: 300 μs each (initial value)
Standard mode (Stnd)Operation and recovery: 1 ms each
Giga Power Mode
(GIGA)
Operation and recovery: 4 ms each
Sensitivity AdjustmentSmart tuning [Fine positioning (initial value), 2-point tuning, positioning tuning,
percent tuning (-99% to 99%), full auto tuning] or manual adjustment
Maximum number of units that can be connected30 units16 units30 units when using E3NW-ECT*6,
16 units when using E3NW-CCL
Mutual interference prevention number of unitsUp to 5 units, intermittent oscillation method (response time = (number of connected units + 1) × 15 ms)
functionOperating modeNO (ON during detection) / NC (ON during non-detection)
TimerSelectable from timer function disabled, off-delay, on-delay, one-shot, and on/off-delay.
1 ms to 9,999 ms
Differential detectionSingle edge: Switchable between 250/500 μs, 1, 10, and 100 ms
Zero resetAvailable
When zero reset is performed, the operation point (detection distance) will change.
Depending on the settings before zero reset, the threshold display may also change after zero reset.
Reset settings *7Selectable from initial reset (factory default) and user reset (saved state)
Eco modeSelectable from OFF (digital display lit), ECO ON (digital display off), and ECO LO (digital display dimly lit)
Bank switching settingsSelectable from BANK1 to 4
Output 1 SettingsSelectable from normal detection mode, area detection mode, and differential detection mode
Output 2 settingsNormal detection mode / alarm output mode /
Error output mode / disconnection detection output mode
Selectable from
--Normal detection mode /
Alarm Output Mode/
Error Output Mode/
Selectable from Disconnection Detection Output Mode
External input settingsInput OFF,
2-point tuning,
percent tuning,
automatic tuning fine positioning,
zero reset,
synchronous detection,
BANK switching selectable
-Input OFF,
2-point tuning,
percent tuning,
automatic tuning fine positioning,
zero reset,
synchronous detection,
BANK switching selectable
--
Hysteresis width settingSelectable from standard settings or user settings. In case of user settings, hysteresis width can be set from 0 to 9,999
Method of changing over the indicationThreshold/detection amount, peak detection amount/bottom detection amount,
bar indication, peak detection amount/detection amount, CH number/detection amount can be set
Threshold/detection ratio,
Peak detection/bottom detection,
Threshold bar display,
Peak detection/detection,
CH number/detection
Ambient temperature rangeDuring operation:
When connecting 1 to 2 units: -25 to +55°C,
When connecting 3 to 10 units: -25 to +50°C,
When connecting 11 to 16 units: -25 to +45°C,
When connecting 17 to 30 units: -25 to +40°C
When storing: -30 to +70°C (no freezing or condensation)
During operation:
When connecting 1 to 2 units: 0 to +55°C,
When connecting 3 to 10 units: 0 to +50°C,
When connecting 11 to 16 units: 0 to +45°C,
When connecting 17 to 30 units: 0 to +40°C
When storing: -30 to +70°C
(no freezing or condensation)
Ambient humidity rangeWhen operating/storing: 35 to 85% RH each (no condensation)
High2,000 m or less
Installation environmentPollution Level 3
ItemsTypeHigh-functionFor sensor communication unit *1
NPN outputModel E2NC-EA21Model E2NC-EA7TWModel E2NC-EA7Model E2NC-EA10Model E2NC-EA0
PNP outputModel E2NC-EA51Model E2NC-EA9TWModel E2NC-EA9Model E2NC-EA40
Connection methodPre-wired (2 m)Connector for simplified wiringSensor communication
unit connector
pre-wired (2 m)
Sensor communication
Connector for unit
Insulation resistance20 MΩ or more (500 V DC insulation resistance tester)
Withstand voltage1,000 V AC 50/60 Hz for 1 min
Vibration (endurance)10 to 55 Hz, 1.5 mm double amplitude for 2 hours in each of X, Y, and Z directions
Shock (endurance)500 m/s2 in Each X, Y, Z Direction 3 times150 m/s2 in Each X, Y, Z Direction 3 times
Weight (Packaging state / Main body only)approx. 115 g / approx. 75 gapprox. 60 g / approx. 20 gapprox. 60 g / approx. 20 gapprox. 95 g / approx. 45 gapprox. 65 g / approx. 25 g
MaterialCasePolycarbonate (PC)
coverPolycarbonate (PC)
CordPVC
AccessoryInstruction manual

*1. Only the EtherCAT type E3NW-ECT and CC-Link type E3NW-CCL communication units are supported. It cannot be used with model E3NW-CRT.
*2. The output from the cord lead-out is the 1CH output of each amplifier unit.
*3. 2 sensor outputs are assigned to the PLC through the network.
    By operating via the PLC network, various settings can be changed and detection values can be read.
*4. Details regarding the input are as follows.

-Contact input (relay, switch)Non-contact input (transistor)Manual time *4-1
NPN type
Model E2NC-EA21
Model E2NC-EA7
When ON: short-circuit to 0 V (outflow current: 1 mA or less)
When OFF: open, or short-circuit to Vcc
When ON: 1.5 V or less (outflow current: 1 mA or less)
When OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA or less)
ON: 9 ms or more
OFF: 20 ms or more
PNP type
Model E2NC-EA51
Model E2NC-EA9
When ON: short-circuit to Vcc (sink current: 3 mA or less)
When OFF: open, or short-circuit to 0 V
When ON: Vcc - 1.5 V to Vcc (sink current: 3 mA or less)
When OFF: 1.5 V or less (leakage current: 0.1 mA or less)

    *4-1. Only when tuning or fine positioning is selected by external input, both ON and OFF must be 25 ms or more.
*5. Power consumption
    When the power supply voltage is 10 V to 30 V
    Normal mode: 1,110 mW or less (37 mA or less current consumption at 30 V power supply voltage / 76 mA or less current consumption at 10 V power supply voltage)
Eco function ON: 900 mW or less (30 mA or less current consumption at 30 V power supply voltage / 48 mA or less current consumption at 10 V power supply voltage)
Eco function LO: 1,020 mW or less (34 mA or less current consumption at 30 V power supply voltage / 58 mA or less current consumption at 10 V power supply voltage)
*6. When connected to the Omron NJ series. Please refer to the communication unit manual for details.
*7. BANK is not reset by user reset and is not saved by user save.

Part Number
E2NC-EA0
E2NC-EA7
E2NC-EA7TW
E2NC-EA9
E2NC-EA9TW
E2NC-EA21 2M
E2NC-EA51 2M
E2NC-ED01-F
E2NC-ED02
E2NC-ED02-F
E2NC-EDR6-F
E2NC-EM02-F
E2NC-EM02H
E2NC-EM07M
E2NC-EM07M-F
E2NC-EV05
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipHead Size (Sensor Shape: Cylinder Type) Detection Direction (Sensor Shape Square) Detection Distance (Range)
(mm)
Amplifier Type Shield Head Dimension (Sensor Shape Screw Type) Sensor Shape Type Detail Output Mode Detection distance
(mm)
Connector specifications Cord Specifications Protective Structure Input/Output

MYR 956.99

1 Piece(s) 9 Day(s) or more ---Separate Type (Amplifier Only)--OtherAmplifier Unit (Sensor Communication Unit Type)--Connector for Sensor Communication Unit---

MYR 768.33

1 Piece(s) 9 Day(s) or more ---Separate Type (Amplifier Only)--OtherAmplifier Unit (High-function Type)NPN-Wiring-saving Connector--1 Output + 1 Input

MYR 768.33

1 Piece(s) 9 Day(s) or more ---Separate Type (Amplifier Only)--OtherAmplifier Unit (High-function Type)NPN-Wiring-saving Connector--2 Output

MYR 768.33

1 Piece(s) 9 Day(s) or more ---Separate Type (Amplifier Only)--OtherAmplifier Unit (High-function Type)PNP-Wiring-saving Connector--1 Output + 1 Input

MYR 768.33

1 Piece(s) 9 Day(s) or more ---Separate Type (Amplifier Only)--OtherAmplifier Unit (High-function Type)PNP-Wiring-saving Connector--2 Output

MYR 782.46

1 Piece(s) 9 Day(s) or more ---Separate Type (Amplifier Only)--OtherAmplifier Unit (High-function Type)NPN-Cord Pull-out Type--2 Output + 1 Input

MYR 782.46

1 Piece(s) 9 Day(s) or more ---Separate Type (Amplifier Only)--OtherAmplifier Unit (High-function Type)PNP-Cord Pull-out Type--2 Output + 1 Input

MYR 946.01

1 Piece(s) 9 Day(s) or more 5.4-Up to 5Separate Type (Sensor Only)Shield-Cylindrical Column TypeSensor Head (Standard type)-1-Free-cutIP67-

MYR 914.58

1 Piece(s) 9 Day(s) or more 8-Up to 5Separate Type (Sensor Only)Shield-Cylindrical Column TypeSensor Head (Standard type)-2-StandardIP67-

MYR 946.01

1 Piece(s) 9 Day(s) or more 8-Up to 5Separate Type (Sensor Only)Shield-Cylindrical Column TypeSensor Head (Standard type)-2-Free-cutIP67-

MYR 1,015.06

1 Piece(s) 9 Day(s) or more 3-Up to 5Separate Type (Sensor Only)Shield-Cylindrical Column TypeSensor Head (Standard type)-0.6-Free-cutIP67-

MYR 946.01

1 Piece(s) 9 Day(s) or more --Up to 5Separate Type (Sensor Only)ShieldM10Screw TypeSensor Head (Standard type)-2-Free-cutIP67-

MYR 2,045.69

1 Piece(s) 9 Day(s) or more --Up to 5Separate Type (Sensor Only)ShieldM12Screw TypeSensor Head (Heat-resistant type)-2-StandardIP67-

MYR 914.58

1 Piece(s) 9 Day(s) or more --6 to 10Separate Type (Sensor Only)Non-ShieldM18Screw TypeSensor Head (Standard type)-7-StandardIP67-

MYR 946.01

1 Piece(s) 9 Day(s) or more --6 to 10Separate Type (Sensor Only)Non-ShieldM18Screw TypeSensor Head (Standard type)-7-Free-cutIP67-

MYR 983.63

1 Piece(s) 9 Day(s) or more -Side DetectionUp to 5Separate Type (Sensor Only)Shield-Square-ShapedSensor Head (Standard type)-5-StandardIP67-

Loading...