Smart Fiber Amplifier E3NX-FA (Part Numbers)

Smart Fiber Amplifier E3NX-FA

Click this image to zoom it.

Move the mouse over the image to zoom

It is an [Advanced] fiber amplifier with a difference in on-site response. Detection distance: 2 basic performances of 1.5 times, minimum detection object: about 1/10 times, have improved.

[Features]
· Detection distance: 2 basic performances of 1.5 times, minimum detection object: about 1/10 times*, have improved.
· Easy setting [Smart tuning] with advanced light volume adjustment range of 40,000 times
· Even with saturation of the amount of received light, it is optimized by light quantity adjustment and stable detection is achieved. Provision for high visibility [white display].
· Difference between passing time and light receiving amount are visible[Solution viewer] and is reliable with [Change finder] where display value of high speed work can be seen

PDF

Drawing

Pre-Wired Type

Smart Fiber Amplifier E3NX-FA, pre-wired type, drawing

*Cord specifications

Part numberOuter diameterNumber of wiresOthers
Model E3NX-FA11 (-5)⌀4.03 contactsConductor cross-sectional area: 0.2 mm2
Insulator diameter: ⌀0.9 mm
Standard length: 2 m
Minimum bending radius: 12 mm
Model E3NX-FA41
Model E3NX-FAH*1
Model E3NX-FA*1AN
Model E3NX-FA21⌀4.05 Pins
Model E3NX-FA51

Reduced wiring connector type

Smart fiber amplifier E3NX-FA, wire saving connector type, drawing

*Cord specifications

Part numberOuter diameterNumber of wires
E3X-CN12⌀2.6Simplex
E3X-CN22⌀4.02 contacts
E3X-CN113 contacts
Model E3X-CN214 contacts

M8 connector type

Smart fiber amplifier E3NX-FA, M8 connector type, drawing

Connector type for sensor communication unit

Smart fiber amplifier E3NX-FA, connector type for sensor communication unit, drawing

Product Specification

Standard type, high-performance type, infrared type

ItemsTypeStandardHigh-functionInfrared Type
NPN outputModel E3NX-FA11Model E3NX-FA6Model E3NX-FA11-5*1Model E3NX-FA21Model E3NX-FA7Model E3NX-FA7TWModel E3NX-FA24-Model E3NX-FAH11Model E3NX-FAH6
PNP outputModel E3NX-FA41Model E3NX-FA8-Model E3NX-FA51Model E3NX-FA9Model E3NX-FA9TWModel E3NX-FA54Model E3NX-FA54TWModel E3NX-FAH41Model E3NX-FAH8
Connection methodPre-wiredConnector for simplified wiringPre-wiredPre-wiredConnector for simplified wiringM8 ConnectorPre-wiredConnector for simplified wiring
Input/outputOutput1 output2 output1 output2 output1 output2 output1 output
External input-1 input1 input-1 input--
Light source (emission wavelength)Red 4-element light emitting diode (625 nm)Infrared emitting diode (870 nm)
Power supply voltage10 to 30 V DC, including 10% ripple (pp)
Power consumption*2At 24 V power supply voltage
[Standard type]
Normal mode: 840 mW or less (current consumption 35 mA or less),
Eco function ON: 650 mW or less (current consumption 27 mA or less), Eco function LO: 750 mW or less (current consumption 31 mA or less)
[High-performance type / Sensor communication unit type]
Normal mode: 920 mW or less (current consumption: 38 mA or less),
Eco function ON: 680 mW or less (current consumption: 28 mA or less), Eco function LO: 800 mW or less (current consumption: 33 mA or less)
[Infrared Type]
Normal mode: 1080 mW or less (current consumption: 45 mA or less)
Eco mode ON: 920 mW or less (current consumption 38 mA or less), Eco mode LO: 1020 mW or less (current consumption 42 mA or less)
Control outputLoad power supply voltage: 30 V DC or less, open collector output type (varies depending on NPN/PNP output type)
Load current: 100 mA or less when connecting 1 to 3 units, 20 mA or less when connecting 4 or more units
(residual voltage, less than 10 mA load current: 1 V or less, 10 to 100 mA load current: 2 V or less)
Off-state current: 0.1 mA or less
External input-See *3-See *3-
Indicator light7-segment display (sub-digital display: green, main digital display: white)
Display direction: Normal / reverse display switchable
OUT indicator light (orange), L/D indicator light (orange), ST indicator light (blue), DPC indicator light (green)
OUT selection indicator light (orange) (2 output only)
Protection circuitPower supply reverse connection protection, output short circuit protection, output reverse connection protection
Response
time
Fastest mode (SHS)Operation and recovery: 30 μs each for single output type (60 μs each in fastest mode (SHS2) for model E3NX-FA11-5)
32 μs each for dual output type
High-speed mode (HS)Operation and recovery: 250 μs each
Standard mode (Stnd)Operation and recovery: 1 ms each
Giga Power mode (GIGA)Operation and recovery: 16 ms each
Sensitivity AdjustmentSmart tuning (2-point tuning, full auto tuning, positioning tuning, maximum sensitivity tuning,
power tuning, percent tuning (-99% to +99%)) or manual adjustment
Maximum number of units that can be connected30 units
Mutual
interference
prevention
units*4
Fastest mode (SHS)0 units
Note: When the detection function is set to the fastest mode (SHS2), the E3NX-FA11-5 model supports 2 units. When other models are set to the fastest mode (SHS),
the mutual interference prevention function is disabled.
High-speed mode (HS)10 units
Standard mode (Stnd)10 units
Giga Power mode (GIGA)10 units
functionAuto power
control (APC)
Available (always enabled)
Dynamic power
control (DPC)
available
TimerSelectable from timer function disabled, off-delay, on-delay, one-shot, and on/off-delay. 1 ms to 9,999 ms
Zero resetNegative display possible (The threshold also shifts)
Reset settings*5Selectable from initial reset (factory default) and user reset (saved state)
Eco mode*6Selectable from OFF (digital display lit), ECO ON (digital display off), and ECO LO (digital display dimly lit)
Bank switching settingsSelectable from BANK1 to 4
Power tuning
at the time of shipment
Selectable from ON/OFF and execute at power startSelectable from ON/OFF
Output 1 SettingsSelectable from normal detection mode, area detection mode, and differential detection modeSelectable from normal detection mode,
area detection mode
Output 2 settings-Normal detection
mode,
alarm
output
mode,
error
output
mode,
differential detection
mode
can be selected
-Normal detection
mode,
alarm
output
mode,
error
output
mode,
differential detection
mode
can be selected
-Normal detection
mode,
alarm
output
mode,
error
output
mode,
differential detection
mode
can be selected
-
External input settings-Input OFF,
tuning,
power tuning,
light emission OFF,
zero reset,
BANK switching
can be selected
-Input OFF,
tuning,
power
tuning,
light emission OFF,
zero reset,
BANK switching
can be selected
-
Hysteresis width settingSelectable from standard settings or user settings. In case of user settings, hysteresis width can be set from 0 to 9,999
Operating ambient illuminanceLight receiving surface illuminance, Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less
Ambient temperature range*7During operation:
When connecting 1 to 2 units: -25°C to +55°C,
When connecting 3 to 10 units: -25°C to +50°C,
When connecting 11 to 16 units: -25°C to +45°C,
When connecting 17 to 30 units: -25°C to +40°C
When storing: -30 to +70°C (no freezing or condensation)
Ambient humidity rangeWhen operating/storing: 35 to 85% RH each in the above ambient temperature range (no condensation)
High2,000 m or less
Installation environmentPollution Level 3
Insulation resistance20 MΩ or more (500 V DC insulation resistance tester)
Withstand voltage1,000 V AC 50/60 Hz for 1 min
Vibration (endurance)10 to 55 Hz, 1.5 mm double amplitude, 2 hours in each direction of X, Y, and Z
Shock (endurance)500 m/s2 in Each X, Y, Z Direction 3 times
Weight
(packaging state/main body only)
approx. 115 g/
approx. 75 g
approx. 60 g/
approx. 20 g
approx. 115 g/
approx. 75 g
approx. 115 g/
approx. 75 g
approx. 60 g / approx. 20 gapprox. 65 g / approx. 25 gapprox. 115 g/
approx. 75 g
approx. 60 g/
approx. 20 g
MaterialCasePolycarbonate (PC)
coverPolycarbonate (PC)
CordPVC
AccessoryInstruction manual

*1. In SHS2 mode, this type supports mutual interference prevention for up to two units.
*2. When the power supply voltage is 10 V to 30 V
   [Standard type]
   Normal mode: 990 mW or less (33 mA or less current consumption at 30 V power supply voltage / 65 mA or less current consumption at 10 V power supply voltage)
Eco function ON: 780 mW or less (26 mA or less current consumption at 30 V power supply voltage / 42 mA or less current consumption at 10 V power supply voltage)
Eco function LO: 840 mW or less (28 mA or less current consumption at 30 V power supply voltage / 45 mA or less current consumption at 10 V power supply voltage)
[Advanced Function Type]
Normal mode: 1,020 mW or less (34 mA or less current consumption at 30 V power supply voltage / 67 mA or less current consumption at 10 V power supply voltage)
Eco function ON: 810 mW or less (27 mA or less current consumption at 30 V power supply voltage / 44 mA or less current consumption at 10 V power supply voltage)
Eco function LO: 870 mW or less (29 mA or less current consumption at 30 V power supply voltage / 48 mA or less current consumption at 10 V power supply voltage)
[Infrared type]
Normal mode: 1,260 mW or less (42 mA or less current consumption at 30 V power supply voltage / 80 mA or less current consumption at 10 V power supply voltage)
Eco function ON: 1,050 mW or less (35 mA or less current consumption at 30 V power supply voltage / 60 mA or less current consumption at 10 V power supply voltage)
Eco function LO: 1,140 mW or less (38 mA or less current consumption at 30 V power supply voltage / 70 mA or less current consumption at 10 V power supply voltage)

*3. The details regarding input are as follows.

-Contact input (relay, switch)Non-contact input (transistor)Input time *3-1
NPN typeWhen ON: short-circuit to 0 V (outflow current: 1 mA or less)
When OFF: open, or short-circuit to Vcc
When ON: 1.5 V or less (outflow current: 1 mA or less)
When OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA or less)
ON: 9 ms or more
OFF: 20 ms or more
PNP typeWhen ON: short-circuit to Vcc (sink current: 3 mA or less)
When OFF: open, or short-circuit to 0 V
When ON: Vcc - 1.5 V to Vcc (sink current: 3 mA or less)
When OFF: 1.5 V or less (leakage current: 0.1 mA or less)

   *3-1. Only when tuning or power tuning is selected by external input, both ON and OFF must be 25 ms or more.

* 4. Tuning does not change the number of units. This is the smallest number of mutual interference prevention units for the models E3NX and E3NC.
Check the number of mutual interference prevention units and response speed for each model.
* 5. BANK is not reset by user reset and is not saved by user save.
*6. The Eco function LO has been added from the July 2014 production lot.
*7. If the number of connected units is 11 or more, the ambient temperature range will be less than 50°C.

Analog output type, sensor communication unit type

ItemsTypeAnalog output typeFor sensor communication unit
NPN outputModel E3NX-FA11ANModel E3NX-FA10Model E3NX-FA0Model E3NX-FAH0
PNP outputModel E3NX-FA41ANModel E3NX-FA40
Connection methodPre-wiredFor sensor communication unit
Pre-wired with connector
Connection connector for sensor communication unit
Input/outputOutput2 output1 output- *1
External input--
Light source (emission wavelength)Red 4-element light emitting diode (625 nm)Infrared emitting diode (870 nm)
Power supply voltage10 to 30 V DC, including 10% ripple (pp)Supplied from the connector through the sensor communication unit
Power consumption*2At 24 V power supply voltage
Normal mode: 960 mW or less
(current consumption: 40 mA or less)
Eco mode ON: 770 mW or less
(current consumption: 32 mA or less)
Eco mode LO: 870 mW or less
(current consumption: 36 mA or less)
At 24 V power supply voltage
Normal mode: 920 mW or less
(current consumption: 38 mA or less)
Eco function ON: 680 mW or less
(current consumption: 26 mA or less)
Eco function LO: 800 mW or less
(current consumption: 33 mA or less)
At 24 V power supply voltage
Normal mode: 1,080 mW or less
(current consumption: 45 mA or less)
Eco function ON: 920 mW or less
(current consumption: 38 mA or less)
Eco function LO: 1020 mW or less
(current consumption: 42 mA or less)
Control outputLoad power supply voltage: 30 V DC or less,
open collector output type
(Depends on NPN/PNP output format)
Load current: 100 mA or less when connecting 1 to 3 units,
20 mA or less when connecting 4 or more units
(residual voltage
less than 10 mA load current: 1 V or less,
10 to 100 mA load current: 2 V or less)
Off-state current: 0.1 mA or less
-
Analog output (reference value)Voltage output: DC 1–5 V
(Load of 10 kΩ or more connected)
Temperature characteristics: 0.3% F.S./°C
-
Indicator light7-segment display (sub-digital display: green, main digital display: white)
Display direction: Normal / reverse display switchable
OUT indicator light (orange), L/D indicator light (orange), ST indicator light (blue), DPC indicator light (green)
OUT selection indicator light (orange) (2 output only)
Protection circuitPower supply reverse connection protection, output short circuit protection, output reverse connection protectionPower supply reverse connection protection, output short circuit protection
Control output
Response time
Fastest mode (SHS)Operation and recovery: 80 μs eachOperation and recovery: 32 μs each
High-speed mode (HS)Operation and recovery: 250 μs eachOperation and recovery: 250 μs each
Standard mode (Stnd)Operation and recovery: 1 ms eachOperation and recovery: 1 ms each
Giga Power mode (GIGA)Operation and recovery: 16 ms eachOperation and recovery: 16 ms each
Sensitivity AdjustmentSmart tuning (2-point tuning, full auto tuning, positioning tuning, maximum sensitivity tuning,
power tuning, percent tuning (-99% to +99%)) or manual adjustment
Maximum number of units that can be connected30 units16 units30 units when using model E3NW-ECT
(When connected to the Omron NJ series)
16 units when using model E3NW-CRT
(Note: Model E3NX-FAH0 cannot be connected.)
16 units when using model E3NW-CCL
Mutual interference prevention units*3Fastest mode (SHS)0 units (Note: When the detection function is set to the fastest mode (SHS), the mutual interference prevention function is disabled.)
High-speed mode (HS)10 units
Standard mode (Stnd)10 units
Giga Power Mode
(GIGA)
10 units
functionAuto power control
(APC)
Available (always enabled)
Dynamic power control
(DPC)
available
TimerSelectable from timer function disabled, off-delay, on-delay, one-shot, and on/off-delay. 1 ms to 9,999 ms
Zero resetNegative display possible (The threshold also shifts)
Reset settings*4Selectable from initial reset (factory default) and user reset (saved state)
Eco modeSelectable from OFF (digital display lit), ECO ON (digital display off), and ECO LO (digital display dimly lit)
Bank switching settingsSelectable from BANK1 to 4
Power tuning settingsSelectable from ON/OFF
Output 1 SettingsSelectable from Normal detection mode, Area detection mode, and Differential detection mode (only for models E3NX-FA10/40)
Output 2 settingsSelectable from analog scaling,
analog offset,
and more
-Selectable from Normal detection mode,
Alarm output mode,
Error output mode,
or Differential detection mode (E3NX-FA0 model only)
.
Hysteresis width settingSelectable from standard settings or user settings. In case of user settings, hysteresis width can be set from 0 to 9,999
Operating ambient illuminanceLight receiving surface illuminance, Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less
Ambient temperature range*5During operation:
When connecting 1 to 2 units:
-25°C to +55°C,
When connecting 3 to 10 units:
-25°C to +50°C,
When connecting 11 to 16 units:
-25°C to +45°C,
When connecting 17 to 30 units:
-25 to +40°C
When storing:
-30 to +70°C
(no freezing or condensation
)
During operation:
When 1 to 2 units are connected: 0 to 55°C,
When 3 to 10 units are connected: 0 to 50°C,
When 11 to 16 units are connected: 0 to 45°C
When storing:
-30 to +70°C
(no freezing or condensation
)
During operation:
When connecting 1 to 2 units: 0 to 55°C,
When connecting 3 to 10 units: 0 to 50°C,
When connecting 11 to 16 units: 0 to 45°C,
When connecting 17 to 30 units: 0 to 40°C
When storing:
-30 to +70°C (no freezing or condensation)
Ambient humidity rangeWhen operating/storing: 35 to 85% RH each in the above ambient temperature range (no condensation)
High2,000 m or less
Installation environmentPollution Level 3
Insulation resistance20 MΩ or more (500 V DC insulation resistance tester)
Withstand voltage1,000 V AC 50/60 Hz for 1 min
Vibration (endurance)10 to 55 Hz, 1.5 mm double amplitude for 2 hours in each of X, Y, and Z directions
Shock (endurance)500 m/s2 
X, Y, Z directions 3 times each
150 m/s2 in each X, Y, Z direction 3 times
Weight (Packaging state / Main body only)approx. 115 g / approx. 75 gapprox. 95 g / approx. 45 gapprox. 65 g / approx. 25 gapprox. 65 g / approx. 25 g
MaterialCasePolycarbonate (PC)
coverPolycarbonate (PC)
CordPVC
AccessoryInstruction manual

* 1. 2 sensor outputs are assigned to the PLC through the network.
    By operating via the PLC network, various settings can be changed and detection values can be read.
*2. When the power supply voltage is 10 V to 30 V
    [Analog output type]
Normal mode: 1,080 mW or less (36 mA or less current consumption at 30 V power supply voltage / 75 mA or less current consumption at 10 V power supply voltage)
Eco function ON: 840 mW or less (28 mA or less current consumption at 30 V power supply voltage / 55 mA or less current consumption at 10 V power supply voltage)
Eco function LO: 960 mW or less (32 mA or less current consumption at 30 V power supply voltage / 65 mA or less current consumption at 10 V power supply voltage)
*3. Tuning does not change the number of units.
This is the smallest number of mutual interference prevention units for the models E3NX and E3NC. Check the number of mutual interference prevention units and response speed for each model.
*4. BANK is not reset by user reset and is not saved by user save.
*5. If the number of connected units is 11 or more, the ambient temperature range will be less than 50°C.

Part Number
E3NX-FA0
E3NX-FA6
E3NX-FA6M
E3NX-FA7
E3NX-FA7M
E3NX-FA7TW
E3NX-FA8
E3NX-FA9TW
E3NX-FA11 2M
E3NX-FA11 5M
E3NX-FA11AN 2M
E3NX-FA11M 2M
E3NX-FA21 2M
E3NX-FA21M 2M
E3NX-FA24
E3NX-FA41 2M
E3NX-FA51 2M
E3NX-FA54
E3NX-FAH11 2M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Detected Objects Light Source Amplifier Installation Type Detection Distance [Classification]
(mm)
Ambient Operating Temperature
(°C)
Amplifier Function (Selectable only when Amplifier is installed) Product Type Output Mode Operation Mode Cable Length
(m)
Timer Applicable Sensors Overview Input/Output Mounting Method Specifications Type Light Source Connection Method Operating Ambient Temperature Range
(°C)
Cord Length
(m)

MYR 844.23

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects[Red] Red 4-element type light emitting diodeAmplifier only-0 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)Threshold Automatic Correction / Counter / External Input / Response time setting / Power Tuning FunctionSensor communication unit type-Light ON/Dark-ON (selectable)-----DIN rail or optional bracket (type E39-L143)Smart tuning--Connector type (for sensor communication unit)--

MYR 674.18

1 Piece(s) 2 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects / Microscopic Object[Red] Red 4-element type light emitting diodeAmplifier only~400-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)Threshold Automatic Correction / Counter / External Input / Response time setting / Power Tuning FunctionStandard typeNPNLight ON/Dark-ON (selectable)----1 OutputDIN rail or optional bracket (type E39-L143)Smart tuning--Connector type (wire-saving)--

MYR 789.65

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects[Red] Red 4-element type light emitting diodeAmplifier only--25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)-Standard typeNPNLight ON/Dark-ON (selectable)----1 Output-Manual adjustment of fiber emitting light intensity--Connector type (wire-saving)--

MYR 814.46

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects / Microscopic Object[Red] Red 4-element type light emitting diodeAmplifier only~400-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)Threshold Automatic Correction / Counter / External Input / Response time setting / Power Tuning FunctionHigh function typeNPNLight ON/Dark-ON (selectable)----1 Output + 1 InputDIN rail or optional bracket (type E39-L143)Smart tuning--Connector type (wire-saving)--

MYR 814.46

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects / Microscopic Object[Red] Red 4-element type light emitting diodeAmplifier only~400-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)Threshold Automatic Correction / Counter / External Input / Response time setting / Power Tuning FunctionHigh function typeNPNLight ON/Dark-ON (selectable)----1 Output + 1 InputDIN rail or optional bracket (type E39-L143)Manual adjustment of fiber emitting light intensity--Connector type (wire-saving)--

MYR 814.46

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects / Microscopic Object[Red] Red 4-element type light emitting diodeAmplifier only~400-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)Threshold Automatic Correction / Counter / External Input / Response time setting / Power Tuning FunctionHigh function typeNPNLight ON/Dark-ON (selectable)----2 OutputDIN rail or optional bracket (type E39-L143)Smart tuning--Connector type (wire-saving)--

MYR 789.65

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects / Microscopic Object[Red] Red 4-element type light emitting diodeAmplifier only~400-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)Threshold Automatic Correction / Counter / External Input / Response time setting / Power Tuning FunctionStandard typePNPLight ON/Dark-ON (selectable)----1 OutputDIN rail or optional bracket (type E39-L143)Smart tuning--Connector type (wire-saving)--

MYR 814.46

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects / Microscopic Object[Red] Red 4-element type light emitting diodeAmplifier only~400-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)Threshold Automatic Correction / Counter / External Input / Response time setting / Power Tuning FunctionHigh function typePNPLight ON/Dark-ON (selectable)----2 OutputDIN rail or optional bracket (type E39-L143)Smart tuning--Connector type (wire-saving)--

MYR 720.60

1 Piece(s) 2 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects / Microscopic Object[Red] Red 4-element type light emitting diodeAmplifier only~400-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)Threshold Automatic Correction / Counter / External Input / Response time setting / Power Tuning FunctionStandard typeNPNLight ON/Dark-ON (selectable)2---1 OutputDIN rail or optional bracket (type E39-L143)Smart tuning--Pre-wired cable--

MYR 792.10

1 Piece(s) 5 Day(s) or more [Fiber Unit] Fiber SensorOpaque Objects[Red] Red 4-element type light emitting diodeAmplifier Separation Type--25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)-Standard typeNPN-5Timer included--1 output-Smart tuningSeparated Type (Amplifier Only)Red light (4 elements)Pre-wired type-25 to +55 (when 1-2 units are connected)5

MYR 1,191.86

1 Piece(s) 9 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects[Red] Red 4-element type light emitting diodeAmplifier only--25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)-Analog output typeNPNLight ON/Dark-ON (selectable)2---2 Output-Smart tuning--Pre-wired cable--

MYR 845.23

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects[Red] Red 4-element type light emitting diodeAmplifier only--25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)-Standard typeNPNLight ON/Dark-ON (selectable)2---1 Output-Manual adjustment of fiber emitting light intensity--Pre-wired cable--

MYR 742.08

1 Piece(s) 2 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects / Microscopic Object[Red] Red 4-element type light emitting diodeAmplifier only~400-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)Threshold Automatic Correction / Counter / External Input / Response time setting / Power Tuning FunctionHigh function typeNPNLight ON/Dark-ON (selectable)2---2 Output + 1 InputDIN rail or optional bracket (type E39-L143)Smart tuning--Pre-wired cable--

MYR 878.26

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects[Red] Red 4-element type light emitting diodeAmplifier only--25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)-High function typeNPNLight ON/Dark-ON (selectable)2---2 Output + 1 Input-Manual adjustment of fiber emitting light intensity--Pre-wired cable--

MYR 877.26

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects[Red] Red 4-element type light emitting diodeAmplifier only~1000-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)External Input / Power Tuning FunctionHigh function typeNPNLight ON/Dark-ON (selectable)--Compatible connector (XS3F-M42*-40*-A)Smart fiber sensor (1 output / 1 input), M8 connector type1 Output + 1 InputDIN rail or optional bracket (type E39-L143)Smart tuning--Connector type (M8)--

MYR 845.23

1 Piece(s) 14 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects / Microscopic Object[Red] Red 4-element type light emitting diodeAmplifier only~400-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)Threshold Automatic Correction / Counter / External Input / Response time setting / Power Tuning FunctionStandard typePNPLight ON/Dark-ON (selectable)2---1 OutputDIN rail or optional bracket (type E39-L143)Smart tuning--Pre-wired cable--

MYR 878.26

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects / Microscopic Object[Red] Red 4-element type light emitting diodeAmplifier only~400-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)Threshold Automatic Correction / Counter / External Input / Response time setting / Power Tuning FunctionHigh function typePNPLight ON/Dark-ON (selectable)2---2 Output + 1 InputDIN rail or optional bracket (type E39-L143)Smart tuning--Pre-wired cable--

MYR 877.26

1 Piece(s) 5 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque Objects[Red] Red 4-element type light emitting diodeAmplifier only~1000-25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)External Input / Power Tuning FunctionHigh function typePNPLight ON/Dark-ON (selectable)--Compatible connector (XS3F-M42*-40*-A)Smart fiber sensor (1 output / 1 input), M8 connector type1 Output + 1 InputDIN rail or optional bracket (type E39-L143)Smart tuning--Connector type (M8)--

MYR 869.58

1 Piece(s) 14 Day(s) or more [Fiber Sensor (Amplifier)] Fiber Sensor (Amplifier)Opaque ObjectsInfrared LEDAmplifier only--25 (when 1 or 2 units are connected)~55 (when 1 or 2 units are connected)-Infrared typeNPNLight ON/Dark-ON (selectable)2---1 Output-Smart tuning--Pre-wired cable--

Loading...

  1. 1
 

Basic Information

Case Material Polycarbonate Operating Environment Cold Resistance Ambient Operating Temperature(%) 35::85
Power Supply Voltage(V) 10-30 V DC Response Time (Standard Mode)(ms) 1 Shape (Amplifier) Square shape

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)