(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
This is a magnetic proximity/contact type switch. Compatible cylinder series: 10S-6R, 10Z-3, 10Z-2R, 10 A-6, 10 A-6L, 10B-6, 10 A-2R, and others

AX101CE, AX111CE, AX125CE

AX11ACE / AX11BCE
| Model Type | With cable (1.5 m) | AX101CE | AX111CE | - | - | - |
|---|---|---|---|---|---|---|
| With Cord (5 m) | - | - | - | - | AX125CE | |
| With Connector (for AC) | - | - | AX11ACE | - | - | |
| With Connector (for DC) | - | - | - | AX11BCE | - | |
| Load Voltage Range | AC: 5 to 120 V, DC: 5 to 30 V | AC: 5 to 120 V | DC: 5 to 30 V | AC: 120 V or less, DC: 30 V or less | ||
| Load Current Range | AC: 5 to 20 mA DC: 5 to 40 mA | 5 to 20 mA | 5 to 40 mA | AC: 20 mA or less, DC: 40 mA or less | ||
| Maximum switching capacity | AC: 2 VA, DC: 1.5 W | |||||
| Internal Voltage Drop | 2 V (at 10 mA), 3 V or less | 0V | ||||
| Leakage current | 0 μA | 10 μA or less | 0 μA | |||
| Operating time | 1 ms or less | |||||
| Reset Time | 1 ms or less | |||||
| Insulation resistance | 100 MΩ or less at 500 V DC insulation resistance tester (between case and cord) | |||||
| Withstand voltage | 1 min. with 1500 V AC (between case and code) | |||||
| Impact resistant | 294 m/s2 (non-repetitive) | |||||
| Vibration resistance | Double amplitude 1.5 mm, 10 to 55 Hz (1 sweep/min) 2 hours in each of X, Y, Z directions | |||||
| Ambient temperature | -10 to +70°C (no freezing) | -10 to +100°C (no freezing) | ||||
| Connection method | 0.3 mm2 2-core outer diameter ⌀4 mm oil-resistant flexible cable | |||||
| Protective Structure | IP67 (IEC standard), JIS C0920 (dustproof and immersion-resistant type) | |||||
| Contact Protection Circuit | Not Included | available | Not Included | |||
| Indicator Light | Red LED (Lights red when ON) | Not Included | ||||
| Applicable Load | Small Relay - Programmable Logic Controller | IC Circuit - Small Relay - Programmable Logic Controller | ||||

AX11ACE (for AC)

AX11BCE (for DC)
| Part Number |
|---|
| AX11ACE |
| AX11BCE |
| AX115CE |
| AX125CE |
| AX215CE |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Sensor Type | Format | Indicator Light | Load Voltage Range① | Load Voltage Range② | Load Current Range① | Load Current Range② | Contact point protection Circuit |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 220.00 | 1 Piece(s) | 13 Day(s) or more | Contacting | With connector (for AC) | Red LED (Lights red when ON) | AC5~120V | - | AC5~20mA | - | Available | ||
MYR 296.81 | 1 Piece(s) | 13 Day(s) or more | Contacting | With connector (for DC) | Red LED (Lights red when ON) | - | DC5~30V | - | DC5~40mA | Available | ||
MYR 184.77 | 1 Piece(s) | 7 Day(s) or more | Contacting | With cable (5 m) | Red LED (Lights red when ON) | AC5~120V | DC5~30V | AC5~20mA | DC5~40mA | Available | ||
MYR 181.17 | 1 Piece(s) | 5 Day(s) or more | Contacting | With cable (5 m) | Not Included | 120 V AC or less | 30 V DC or less | 20 mA AC or less | 40 mA DC or less | Not Included | ||
MYR 319.11 | 1 Piece(s) | 18 Day(s) or more | Non-Contact | With cable (5 m) | Operation position: Red/green LED ON · Optimum position: Green LED ON | DC5~30V | - | DC5~40mA | - | Available |
Loading...
| Output Format | N/A | Wiring Method | 2-Wire | Type | Main Body |
|---|

KOGANEI
Standard Price : MYR 143.90
Days to Ship : 4 Day(s) or more
How can we improve?