(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
PS/C mark (JQA) accredited product. Can simultaneously display the maximum temperature while making measurements. With backlight and laser marker. Auto Power OFF function included (turns off automatically after about 15 seconds). Measurement range is -38 to +365°C.
Part Number
Configured Part Number is shown.
AD-5619
[Specifications]
[Examples of use]

Ratio of distance (D) to measurement area (S)
Distance: Measurement area = 12:1
| Product Image | ![]() |
|---|---|
| Product Name | Infrared thermometer with laser marker AD-5619 |
| Die name | AD-5619 |
| Radiation Thermometer Measurement Range | -38 to +365°C |
| Minimum Display | 0.1°C |
| Radiation Thermometer Response Speed | Approx. 1 second (90%) |
| Response Wavelength | 5μm to 14μm |
| Accuracy | ±2% rdg or ±2°C, whichever is greater |
| Emissivity Setting | 0.95 (fixed) |
| Measurement distance (D): Measurement range (S) | 12:1 |
| Laser marker | Class 2 (JIS C 6802), laser wavelength 635–660 nm, output power 1 mW or less |
| Waterproof specifications | - |
| Battery/Battery lifespan | 2 AAA alkaline batteries / Approx. 14 hours (continuous use, using alkaline batteries) |
| External dimensions/weight | 40 (W) × 156 (H) × 113 (D) mm / approx. 173 g (including batteries) |
| JAN Code | 4981046445412 |
· Calibration certificate included
| Die name | AD5619-00A00 |
|---|---|
| JAN code | 4981046913959 |
| Image | ![]() |
![]() | |
![]() | |
![]() |
(1) Do not point the laser at people. Also, do not look into the laser.
(2) The laser used in this product is classified as Class 2 according to safety standards.
(3) Do not subject the product to strong impacts, vibrations, or electric shocks. Otherwise, it may cause malfunction.
(4) Avoid using the product in places with sudden temperature changes, high temperatures, high humidity, or excessive dust.
(5) This product is not waterproof. Avoid using it underwater or in places where it may be directly exposed to water.
(6) Store in a place out of reach of children. Also, do not allow children to use it.
[HI] The temperature of the measured object is outside the measurement range (upper limit).
[LO] The temperature of the measured object is outside the temperature measurement range (lower limit).
[Er2] The change in ambient temperature is too great. (Example: Measuring after moving from indoors to outdoors, or vice versa)
[Er3] The ambient temperature is outside the operating temperature range.
[Er5–Er9] This is a system error. In this case, please remove the batteries, wait for more than one minute, and then reinsert them. If the issue still cannot be resolved, please request a repair.
| Product Type | Radiation thermometer | Temperature Measuring Range(°C) | -38 ~ 365 | Temperature minimal display(°C) | 0.1 |
|---|---|---|---|---|---|
| Distance to Measuring Range Ratio (D to S) | 12:1 | Power Supply | AAA Battery x 2 | Battery life | Approx. 14 hours (continuous use, when using alkaline batteries) |
| Response Time(Second) | Approx. 1 second (90%) | Width(mm) | 40 | Depth(mm) | 113 |
| Height(mm) | 156 | Reproducibility | 0.2 °C in the case of 25 °C, 0.8 °C for others | Emissivity setting | 0.95 (fixed) |
| Accessory | Battery for monitor, instructions manual | Laser Marker | Class 2 (JIS C 6802) Laser Wavelength 635 nm to 660 nm, Output Power 1 mW or Less | Mass(g) | Approx. 173 |
Please check the type/dimensions/specifications of the part AD-5619 in the Infrared Radiation Thermometer with Laser Marker AD-5619 series.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy