(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Our website upgrade are completed! Latest improvements are now LIVE to enhance your ordering experience. You may be logged out due to the update. Please take note to login again or reset credentials if needed. More details here. 

General purpose inverter FREQROL-F800

General purpose inverter FREQROL-F800

Enhanced next-generation energy-saving inverter

[Features]
· Energy saving
· Ideal functionality for fans and pumps
· Safe and secure
· Environmentally friendly
· Easy to set up and operate

PDF

Ratings (Standard-Structure Product) 200‑V Class

Type Name FR-F820-[](-E)0.75K18.5K37K45K55K75K90K110K
0004600770015400187002330031600380004750
Applied Motor Capacity
(kW)∗1
SLD0.7518.53745557590/110132
LD0.7518.53745557590110
OutputRated Capacity
(kVA)∗2
SLD1.829597189120145181
LD1.627536581110132165
Rated Current
(A)
SLD4.677154187233316380475
LD4.270.5140170212288346432
Overload Current
Rating∗3
SLD110% 60 s, 120% 3 s (for inverse time characteristics) Ambient temperature 40°C
LD120% 60 s, 150% 3 s (for inverse time characteristics) Ambient temperature 50°C
Rated Voltage∗43-phase 200 to 240 V
Power supplyRated Input
AC Voltage / Frequency
3-phase 200 to 240 V, 50 Hz / 60 Hz
Allowable AC Voltage Fluctuation170 to 264 V 50 Hz / 60 Hz
Allowable Frequency Fluctuation±5%
Rated Input
Current (A)
∗5
DC Reactor
No
SLD5.396.7185221269---
LD590.9178207255---
DC Reactor
Yes
SLD4.677154187233316380475
LD4.271140170212288346432
Power Supply Equipment
Capacity
(kVA)∗6
DC Reactor
No
SLD2377084103---
LD1.935687997---
DC Reactor
Yes
SLD1.829597189120145181
LD1.627536581110132165
Protective Structure (IEC 60529)∗7Enclosed type (IP20)Open type (IP00)
Cooling MethodSelf-coolingForced-air cooling
Rough Weight (kg)1.915224242547474

∗1 The applied motor capacity indicates the maximum applied capacity when a 4-pole Mitsubishi Electric standard motor is used.
∗2 The rated output capacity indicates the output capacity when the output voltage is 220 V.
∗3 The percentage value in the overload current rating indicates the percentage vis-a-vis the inverter's rated output current.
When using the inverter repeatedly, it is necessary to wait for the temperature of the inverter and motor to return to or fall below the 100% load temperature between uses.
∗4 The maximum output voltage will never be the same as or exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
Note, however, that the peak value of the voltage waveform on the inverter’s output side is approximately twice the √ of the power supply voltage.
∗5 The rated input current indicates the value at the rated output current. The rated input current varies depending on the value of the power supply impedance (including the impedance of the input reactor and wiring).
∗6 The power supply capacity is the value at the rated output current. This value varies depending on the value of the impedance on the power supply side (including the impedance of the input reactor and wiring).
∗7 FR-DU08: IP40 (excluding the PU connector part)
 

Ratings (Standard-Structure Product) 400‑V Class

Type Name FR-F840-[](-E)0.75K1.5K2.2K5.5K7.5K11K15K18.5K22K30K45K55K75K90K110K132K160K185K220K250K280K
000230003800052001260017000250003100038000470006200093001160018000216002600032500361004320048100547006100
Applied Motor
Capacity (kW)∗1
SLD0.751.52.25.57.5111518.52230455575/90110132160185220250280315
LD0.751.52.25.57.5111518.5223045557590110132160185220250280
OutputRated Capacity
(kVA)∗2
SLD1.82.94101319242936477188137165198248275329367417465
LD1.62.73.78.81218222733436581110137165198248275329367417
Rated Current
(A)
SLD2.33.85.212.617253138476293116180216260325361432481547610
LD2.13.54.811.516232935435785106144180216260325361432481547
Overload Current
Rating∗3
SLD110% 60 s, 120% 3 s (for inverse time characteristics) Ambient temperature 40°C
LD120% 60 s, 150% 3 s (for inverse time characteristics) Ambient temperature 50℃
Rated Voltage∗43-phase 380 to 500 V
Power supplyRated Input
AC Voltage / Frequency
3-phase 380 to 500 V 50 Hz / 60 Hz∗8
Allowable AC Voltage Fluctuation323 to 550 V 50 Hz / 60 Hz
Allowable Frequency Fluctuation±5%
Rated Input
Current (A)
∗5
DC Reactor
No
SLD3.25.47.816.422.531.740.348.258.476.8115141---------
LD34.97.315.122.33138.244.953.975.1106130---------
DC Reactor
Yes
SLD2.33.85.212.617253138476293116180216260325361432481547610
LD2.13.54.811.516232935435785106144180216260325361432481547
Power Supply Equipment
Capacity
(kVA)∗6
DC Reactor
No
SLD2.54.15.91217243137445988107---------
LD2.33.75.5121724293441578199---------
DC Reactor
Yes
SLD1.82.94101319242936477188137165198248275329367417465
LD1.62.73.78.81218222733436581110137165198248275329367417
Protective Structure (IEC 60529)∗7Enclosed type (IP20)Open type (IP00)
Cooling MethodSelf-coolingForced-air cooling
Rough Weight (kg)2.52.52.536.36.38.38.3151541414352557178117117166166

∗1 The applied motor capacity indicates the maximum applied capacity when a 4-pole Mitsubishi Electric standard motor is used.
∗2 The rated output capacity indicates the output capacity when the output voltage is 440 V.
∗3 The percentage value in the overload current rating indicates the percentage vis-a-vis the inverter's rated output current.
When using the inverter repeatedly, it is necessary to wait for the temperature of the inverter and motor to return to or fall below the 100% load temperature between uses.
∗4 The maximum output voltage will never be the same as or exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
Note, however, that the peak value of the voltage waveform on the inverter’s output side is approximately twice the √ of the power supply voltage.
∗5 The rated input current indicates the value at the rated output current. The rated input current varies depending on the value of the power supply impedance (including the impedance of the input reactor and wiring).
∗6 The power supply capacity is the value at the rated output current. This value varies depending on the value of the impedance on the power supply side (including the impedance of the input reactor and wiring).
∗7 FR-DU08: IP40 (excluding the PU connector part)
∗8 If 480 V will be exceeded, it is necessary to configure a setting to select Pr.977 input voltage mode.
 

General Specifications

Control SpecificationsControl MethodSoft-PWM control, high-carrier-frequency PWM control (selectable among V/F control [optimum excitation control, etc.],
advanced magnetic flux vector control [advanced optimum excitation control, etc.] and PM motor control)
Output Frequency Range0.2 to 590 Hz (The upper-limit frequency is 400 Hz under advanced magnetic flux vector control and PM motor control.)
Frequency Setting
Resolution
Analog Input0.015 Hz / 60 Hz (terminal 2, 4: 0 to 10 V / 12 bits)
0.03 Hz / 60 Hz (0 to 5 V / 11 bits or 0 to 20 mA / approx. 11 bits for terminals 2 and 4, 0 to ±10 V / 12 bits for terminal 1)
0.06 Hz / 60 Hz (0 to ±5 V / 11 bits for terminal 1)
Digital Input0.01 Hz
Frequency AccuracyAnalog InputWithin ±0.2% of the max. output frequency (25°C ±10°C)
Digital InputWithin 0.01% of the set output frequency
Voltage / Frequency CharacteristicsBase frequency can be set from 0 to 590 Hz. Constant-torque / variable-torque pattern or adjustable 5 points V/F can be selected
Starting TorqueInduction Motor120% 0.5 Hz (advanced magnetic flux vector control)
IPM Motor50%
Torque BoostManual torque boost
Acceleration/Deceleration Time Setting0 to 3,600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode, backlash countermeasures acceleration/deceleration can be selected
DC Injection Brake (Induction Motor)Operation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30%) variable
Stall Prevention Operation LevelActivation range of stall prevention operation (SLD rating: 0 to 120%, LD rating: 0 to 150%)
Whether to use stall prevention or not can be selected (V/F control, advanced magnetic flux vector control)
Operation SpecificationsFrequency Setting
Signal
Analog InputTerminals 2 and 4: 0 to 10 V, 0 to 5 V, 4 to 20 mA (0 to 20 mA) are available
Terminal 1: -10 to +10 V, -5 to 5 V are available
Digital InputInput using the setting dial of the operation panel or the parameter unit
Four-digit BCD or 16-bit binary (when used with option FR-A8AX)
Start SignalForward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected
Input Signals (12 Terminals)Low-speed operation command, middle-speed operation command, high-speed operation command, second function selection, terminal 4 input selection, JOG operation selection,
output stop, start self-holding selection, forward rotation command, reverse rotation command, inverter reset
The input signal can be changed using Pr.178 to Pr.189 (input terminal function selection).
 Pulse Train Input100 kpps
Operational FunctionsMaximum and minimum frequency settings, multi-speed operation, acceleration/deceleration pattern, thermal protection, DC injection brake, starting frequency, JOG operation,
output stop (MRS), stall prevention, regeneration avoidance, increased magnetic excitation deceleration, DC feeding∗1, frequency jump, rotation display,
automatic restart after instantaneous power failure, electronic bypass sequence, remote setting, retry function, carrier frequency selection, fast response current limit, forward/reverse rotation prevention,
operation mode selection, slip compensation, speed smoothing control, traverse, auto tuning, applied motor selection,
RS-485 communication, Ethernet communication∗5, PID control, PID pre-charge function, cooling fan operation selection,
stop selection (deceleration stop / coasting), power-failure deceleration stop function, PLC function, life diagnosis, maintenance timer,
current average monitor, multiple rating, test run, 24‑V power supply input for control circuit, safety stop function,
self power management, BACnet communication, PID gain tuning, cleaning, load characteristics storage,
emergency drive∗1
Output SignalsOpen Collector Output
(5 Terminals)
Relay Output (2 Terminals)
Inverter running, up to frequency, instantaneous power failure / undervoltage∗1, overload warning, output frequency detection, fault
The output signal can be changed using Pr.190 to Pr.196 (output terminal function selection).
Fault codes of the inverter can be output (4 bits) from the open collector.
Pulse Train Output
(FM Type)
50 kpps
IndicationFor MeterPulse Train Output (FM Type)Max. 2.4 kHz: 1 terminal (output frequency)
The monitored item can be changed using Pr.54 FM/CA terminal function selection.
Current Output (CA Type)Max. 20 mA DC: 1 terminal (output frequency)
The monitored item can be changed using Pr.54 FM/CA terminal function selection.
Voltage outputMax. 10 V DC: 1 terminal (output frequency)
The monitored item can be changed using Pr.158 AM terminal function selection.
Operation Panel
(FR-DU08)
Operating StatusOutput frequency, output current, output voltage, frequency setting value
The monitored item can be changed using Pr.52 Operation panel main monitor selection.
Fault RecordFault record is displayed when a fault occurs; past 8 fault records and the conditions immediately before the fault (output voltage / current / frequency
/ cumulative energization time / year / month / date / time) are saved
Protective/Alarm FunctionsProtective FunctionsOvercurrent trip during acceleration, overcurrent trip during constant speed, overcurrent trip during deceleration or stop, regenerative overvoltage trip during acceleration, regenerative overvoltage trip during constant speed,
regenerative overvoltage trip during deceleration or stop, inverter overload trip (electronic thermal relay function), motor overload trip (electronic thermal relay function),
heatsink overheat, instantaneous power failure∗1, undervoltage∗1, input phase loss∗1∗2, stall prevention stop, loss of synchronism detection∗2, upper limit fault detection,
lower limit fault detection, output side earth (ground) fault overcurrent, output short circuit, output phase loss, external thermal relay operation∗2, PTC thermistor operation∗2,
option fault, communication option fault, parameter storage device fault, PU disconnection, retry count excess∗2,
CPU fault, operation panel power supply short circuit / RS-485 terminal power supply short circuit, 24‑V DC power fault, abnormal output current detection∗2,
inrush current limit circuit fault∗1, communication fault, analog input fault, USB communication fault, safety circuit fault, overspeed occurrence∗2,
4‑mA input fault ∗2, PID pre-charge fault∗2, PID signal fault∗2, internal circuit fault, user definition error in the sequence function
Alarm FunctionsFan alarm, stall prevention (overcurrent), stall prevention (overvoltage), electronic thermal relay function pre-alarm, PU stop,
parameter copy, safety stop, maintenance timer 1 to 3∗2, USB host error, operation panel lock∗2,
password locked∗2, parameter write error, copy operation error, 24‑V external power supply operation, load fault warning,
emergency drive in operation∗1, continuous operation during communication fault∗2, Ethernet communication fault∗5
EnvironmentAmbient Temperature-10°C to +50°C (non-freezing) (LD rating)
-10°C to +40°C (non-freezing) (SLD rating)
Ambient HumidityWith circuit board coating (conforming to IEC60721-3-3 3C2/3S2): 95% RH or less (non-condensing)
Without circuit board coating: 90% RH or less (non-condensing)
Storage Temperature∗3-20°C to +65°C
AtmosphereIndoors (without corrosive gas, flammable gas, oil mist, dust and dirt, etc.)
Altitude/Vibration2,500 m or lower (If installing at a height that exceeds 1,000 m, it is necessary to reduce the rated current by 3% for every 500 m.)
· 5.9 m/s² or less∗4 at 10 to 55 Hz (directions of X, Y, Z axes)

∗1 Available only for the standard model.
∗2 This protective function is not available in the initial status.
∗3 Temperature applicable for a short time, e.g. in transit.
∗4 2.9 m/s² or less for the FR-F840-185K (04320) or higher.
∗5 Only functions in the FR-F800-E.
 

Part Number
FR-F820-0.75K-1
FR-F820-1.5K-1
FR-F820-2.2K-1
FR-F820-5.5K-1
FR-F820-7.5K-1
FR-F820-11K-1
FR-F820-15K-1
FR-F820-18.5K-1
FR-F820-22K-1
FR-F820-30K-1
FR-F820-37K-1
FR-F820-45K-1
FR-F820-55K-1
FR-F820-75K-1
FR-F820-90K-1
FR-F820-110K-1
FR-F840-00052-2-60
FR-F840-00083-2-60
FR-F840-00380-2-60
FR-F840-0.75K-1
FR-F840-0.75K-E1
FR-F840-1.5K-1
FR-F840-1.5K-E1
FR-F840-2.2K-1
FR-F840-3.7K-1
FR-F840-3.7K-2
FR-F840-5.5K-1
FR-F840-5.5K-E1
FR-F840-7.5K-1
FR-F840-7.5K-E1
FR-F840-11K-1
FR-F840-11K-E1
FR-F840-15K-1
FR-F840-15K-2
FR-F840-18.5K-1
FR-F840-18.5K-2
FR-F840-18.5K-E1
FR-F840-22K-1
FR-F840-22K-E1
FR-F840-30K-1
FR-F840-30K-E1
FR-F840-37K-1
FR-F840-37K-2
FR-F840-37K-E1
FR-F840-45K-1
FR-F840-45K-E1
FR-F840-55K-1
FR-F840-55K-E1
FR-F840-75K-1
FR-F840-75K-E1
FR-F840-90K-1
FR-F840-90K-2
FR-F840-90K-E1
FR-F840-110K-1
FR-F840-110K-E1
FR-F840-132K-1
FR-F840-132K-E1
FR-F840-160K-1
FR-F840-160K-E1
FR-F840-185K-1
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipApplicable motor capacity
(kW)
Input voltage class Output capacity
(kVA)
External communications Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Protective Structure Output Rated Current
(A)
Output Rated Power Supply
(V)
Circuit Board Coating Function Terminal Type Conductor Plating

MYR 3,020.00

1 Piece(s) 79 Day(s) 0.75Three-Phase 200 V1.6RS-232/422/485260110110Closed type (IP20)4.23-phase 200 to 240Without---

MYR 3,763.33

1 Piece(s) 79 Day(s) 1.5Three-Phase 200 V2.7RS-232/422/485260110125Closed type (IP20)73-phase 200 to 240Without-FMWithout

MYR 4,188.33

1 Piece(s) 79 Day(s) 2.2Three-Phase 200 V3.7RS-232/422/485260150140Closed type (IP20)9.63-phase 200 to 240Without-FMWithout

MYR 6,960.00

1 Piece(s) 79 Day(s) 5.5Three-Phase 200 V8.8RS-232/422/485260150140Closed type (IP20)233-phase 200 to 240Without-FMN/A

MYR 8,316.67

1 Piece(s) 79 Day(s) 7.5Three-Phase 200 V12RS-232/422/485260220170Closed type (IP20)313-phase 200 to 240Without-FMN/A

MYR 15,660.00

1 Piece(s) 79 Day(s) 11Three-Phase 200 V17RS-232/422/485260220170Closed type (IP20)453-phase 200 to 240Without---

MYR 17,521.67

1 Piece(s) 79 Day(s) 15Three-Phase 200 V22RS-232/422/485300220190Closed type (IP20)583-phase 200 to 240WithoutStandard type-Without

MYR 20,516.67

1 Piece(s) 79 Day(s) 185Three-Phase 200 V27RS-232/422/485400250190Closed type (IP20)70.53-phase 200 to 240Without---

MYR 29,493.33

1 Piece(s) 79 Day(s) 22Three-Phase 200 V25.9RS-232/422/485400250190Closed type (IP20)853-phase 200 to 240Without---

MYR 34,803.33

1 Piece(s) 79 Day(s) 30Three-Phase 200 V43RS-232/422/485400250190Open type (IP00)1143-phase 200 to 240Without-FMN/A

MYR 51,083.33

1 Piece(s) 79 Day(s) 37Three-Phase 200 V53RS-232/422/485550325195Open type (IP00)1403-phase 200 to 240Without---

MYR 66,490.00

1 Piece(s) 79 Day(s) 45Three-Phase 200 V65RS-232/422/485550435250Open type (IP00)1703-phase 200 to 240Without---

MYR 78,585.00

1 Piece(s) 79 Day(s) 55Three-Phase 200 V81RS-232/422/485550435250Open type (IP00)2123-phase 200 to 240Without---

MYR 104,563.33

1 Piece(s) 79 Day(s) 75Three-Phase 200 V110RS-232/422/485700465250Open type (IP00)2883-phase 200 to 240Without---

MYR 119,728.33

1 Piece(s) 79 Day(s) 90Three-Phase 200 V132RS-232/422/485740465360Open type (IP00)3463-phase 200 to 240Without---

MYR 139,680.00

1 Piece(s) 79 Day(s) 110Three-Phase 200 V165RS-232/422/485740465360Open type (IP00)4323-phase 200 to 240Without---

MYR 5,436.66

1 Piece(s) 4 Day(s) 2.2Three-phase 400V4RS-232/422/485260150140Closed type (IP20)5.23-phase 380 to 501WithStandard typeCAWithout

MYR 5,595.00

1 Piece(s) 4 Day(s) 3.7Three-phase 400V6.3RS-232/422/485260150140Closed type (IP20)8.33-phase 380 to 500WithStandard typeCAWithout

MYR 14,843.33

1 Piece(s) 4 Day(s) 1.5Three-phase 400V2.9RS-232/422/485300220190Closed type (IP20)3.83-phase 380 to 500WithStandard typeCAWithout

MYR 4,013.33

1 Piece(s) 79 Day(s) 0.75Three-phase 400V1.6RS-232/422/485260150140Closed type (IP20)2.13-phase 380 to 500WithoutStandard typeFM-

MYR 3,520.00

1 Piece(s) 97 Day(s) 0.75Three-phase 400V1.6Ethernet260150140Closed type (IP20)2.13-phase 380 to 500WithoutStandard typeFMWithout

MYR 4,118.33

1 Piece(s) 79 Day(s) 1.5Three-phase 400V2.7RS-232/422/485260150140Closed type (IP20)3.53-phase 380 to 500WithoutStandard type--

MYR 4,390.00

1 Piece(s) 97 Day(s) 1.5Three-phase 400V2.7Ethernet260150140Closed type (IP20)3.53-phase 380 to 500WithoutStandard typeFMWithout

MYR 4,946.67

1 Piece(s) 79 Day(s) 2.2Three-phase 400V3.7RS-232/422/485260150140Closed type (IP20)4.83-phase 380 to 500WithoutStandard type--

MYR 6,001.67

1 Piece(s) 79 Day(s) 3.7Three-phase 400V4.61RS-232/422/485260150140Closed type (IP20)7.63-phase 380 to 500WithoutStandard typeFMWithout

MYR 6,640.00

1 Piece(s) 97 Day(s) 3.7Three-phase 400V5.8RS-232/422/485260150140Closed type (IP20)7.63-phase 380 to 500WithoutStandard typeCAWithout

MYR 7,151.67

1 Piece(s) 79 Day(s) 5.5Three-phase 400V8.8RS-232/422/485260150140Closed type (IP20)11.53-phase 380 to 500WithoutStandard type--

MYR 7,485.00

1 Piece(s) 97 Day(s) 5.5Three-phase 400V8.8Ethernet260150140Closed type (IP20)11.53-phase 380 to 500WithoutStandard typeFMWithout

MYR 8,530.00

1 Piece(s) 79 Day(s) 7.5Three-phase 400V12RS-232/422/485260220170Closed type (IP20)163-phase 380 to 500WithoutStandard type--

MYR 9,556.66

1 Piece(s) 97 Day(s) 7.5Three-phase 400V12Ethernet260220170Closed type (IP20)163-phase 380 to 500WithoutStandard typeFMWithout

MYR 10,926.67

1 Piece(s) 79 Day(s) 11Three-phase 400V18RS-232/422/485260220170Closed type (IP20)233-phase 380 to 500WithoutStandard type--

MYR 12,243.33

1 Piece(s) 97 Day(s) 11Three-phase 400V18Ethernet260220170Closed type (IP20)233-phase 380 to 500WithoutStandard typeFMWithout

MYR 12,188.33

1 Piece(s) 79 Day(s) 15Three-phase 400V22RS-232/422/485300220190Closed type (IP20)293-phase 380 to 500WithoutStandard type--

MYR 13,500.00

1 Piece(s) 97 Day(s) 15Three-phase 400V22RS-232/422/485300220190Closed type (IP20)293-phase 380 to 500WithoutStandard typeCAWithout

MYR 13,496.67

1 Piece(s) 79 Day(s) 18.5Three-phase 400V27RS-232/422/485300220190Closed type (IP20)353-phase 380 to 500WithoutStandard type--

MYR 14,225.00

1 Piece(s) 97 Day(s) 18.5Three-phase 400V27RS-232/422/485300220190Closed type (IP20)353-phase 380 to 500WithoutStandard typeCAWithout

MYR 15,116.67

1 Piece(s) 97 Day(s) 18.5Three-phase 400V27Ethernet300220190Closed type (IP20)353-phase 380 to 500WithoutStandard typeFMWithout

MYR 14,943.33

1 Piece(s) 79 Day(s) 22Three-phase 400V33RS-232/422/485400250190Closed type (IP20)433-phase 380 to 500WithoutStandard type--

MYR 16,738.33

1 Piece(s) 97 Day(s) 22Three-phase 400V33Ethernet400250190Closed type (IP20)433-phase 380 to 500WithoutStandard typeFMWithout

MYR 19,350.00

1 Piece(s) 79 Day(s) 30Three-phase 400V43RS-232/422/485400250190Closed type (IP20)573-phase 380 to 500WithoutStandard type--

MYR 21,676.67

1 Piece(s) 97 Day(s) 30Three-phase 400V43Ethernet400250190Closed type (IP20)573-phase 380 to 500WithoutStandard typeFMWithout

MYR 23,085.00

1 Piece(s) 79 Day(s) 37Three-phase 400V53RS-232/422/485550325195Open type (IP00)703-phase 380 to 500WithoutStandard typeFMWithout

MYR 25,536.66

1 Piece(s) 97 Day(s) 37Three-phase 400V53RS-232/422/485550325195Closed type (IP20)703-phase 380 to 500WithoutStandard typeCAWithout

MYR 25,860.00

1 Piece(s) 97 Day(s) 37Three-phase 400V53Ethernet550325195Open type (IP00)703-phase 380 to 500WithoutStandard typeFMWithout

MYR 29,876.67

1 Piece(s) 79 Day(s) 45Three-phase 400V65RS-232/422/485550435250Open type (IP00)853-phase 380 to 500WithoutStandard type--

MYR 33,465.00

1 Piece(s) 97 Day(s) 45Three-phase 400V65Ethernet550435250Closed type (IP20)853-phase 380 to 500WithoutStandard typeFMWithout

MYR 35,475.00

1 Piece(s) 79 Day(s) 55Three-phase 400V81RS-232/422/485550435250Open type (IP00)1063-phase 380 to 500WithoutStandard type--

MYR 39,740.00

1 Piece(s) 97 Day(s) 55Three-phase 400V81Ethernet550435250Open type (IP00)1063-phase 380 to 500WithoutStandard typeFMWithout

MYR 55,661.67

1 Piece(s) 79 Day(s) 75Three-phase 400V110RS-232/422/485550435250Open type (IP00)1443-phase 380 to 500WithoutStandard type--

MYR 62,353.33

1 Piece(s) 97 Day(s) 75Three-phase 400V110Ethernet550435250Closed type (IP20)1443-phase 380 to 500WithoutStandard typeFMWithout

MYR 63,651.67

1 Piece(s) 79 Day(s) 90Three-phase 400V137RS-232/422/485620465300Open type (IP00)1803-phase 380 to 500WithoutStandard type--

MYR 70,411.66

1 Piece(s) 97 Day(s) 90Three-phase 400V137RS-232/422/485620465300Closed type (IP20)1803-phase 380 to 500WithoutStandard typeCAWithout

MYR 71,303.33

1 Piece(s) 97 Day(s) 90Three-phase 400V137Ethernet620465300Closed type (IP20)1803-phase 380 to 500WithoutStandard typeFMWithout

MYR 74,258.33

1 Piece(s) 79 Day(s) 110Three-phase 400V165RS-232/422/485620465300Open type (IP00)2163-phase 380 to 500WithoutStandard type--

MYR 83,188.33

1 Piece(s) 97 Day(s) 110Three-phase 400V165Ethernet620465300Closed type (IP20)2163-phase 380 to 500WithoutStandard typeFMWithout

MYR 87,413.33

1 Piece(s) 97 Day(s) 132Three-phase 400V198RS-232/422/485740465360Open type (IP00)2603-phase 380 to 500WithoutStandard type--

MYR 97,920.00

1 Piece(s) 97 Day(s) 132Three-phase 400V198Ethernet740465360Closed type (IP20)2603-phase 380 to 500WithoutStandard typeFMWithout

MYR 97,596.67

1 Piece(s) 97 Day(s) 160Three-phase 400V248RS-232/422/485740465360Open type (IP00)3253-phase 380 to 500WithoutStandard type--

MYR 109,330.00

1 Piece(s) 97 Day(s) 160Three-phase 400V248Ethernet740465360Closed type (IP20)3253-phase 380 to 500WithoutStandard typeFMWithout

MYR 114,993.33

1 Piece(s) 97 Day(s) 185Three-phase 400V275RS-232/422/4851010498380Open type (IP00)3613-phase 380 to 500WithoutStandard type--

Loading...

 

Basic Information

Output Specification Three-Phase Representative Standard CE / UL / CUL

Additional Products in this Category

Tech Support