(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Our website upgrade are completed! Latest improvements are now LIVE to enhance your ordering experience. You may be logged out due to the update. Please take note to login again or reset credentials if needed. More details here. 

Molded Case Circuit Breakers (MCCB) NF-CV/SV (NF63-CVF 3P 40A)

Molded Case Circuit Breakers (MCCB) NF-CV/SV NF63-CVF 3P 40A
  • Volume Discount

· Molded Case Circuit Breakers (MCCB) NF-CV/SV series from MITSUBISHI.
· Rated Current Range: 3.4A to 63A (varies by model)
· Number of Poles: 2, 3, or 4 (model-dependent)
· Rated Insulation Voltage: 500V or 600V (model-dependent)
· Rated Short-Circuit Breaking Capacity: AC voltages: 230V to 690V, DC voltage: 250V (for some models)
· Short-Circuit Breaking Capacity Range: 2.5/2.5 kA to 75/75 kA (varies by voltage and model)
· Standard Attached Parts: Terminal screw: M5×14, Mounting screw: M4×0.7×55 and Insulation barrier

PDF

Part Number

Configured Part Number is shown.

NF63-CVF 3P 40A

NF-MB Type MCCB for MITSUBISHI Circuit Breakers Protection: Specification Table

Frame A303250100
Circuit Breakers ModelNF32-SVNF63-CVNF63-SVNF-125-SV
Number of Poles33333
Rated Insulation Voltage Ui (V)500500500500500
Rated
Short
Circuit
Breaking
Capacity
(kA)


JIS C 8201-2-1 Ann.1
JIS C 8201-2-1 Ann.2
IEC 60947-2
EN 60947-2
(Icu/Ics)
AC440 V2.5/2.52.5/2.52.5/2.57.5/7.525/25
415 V2.5/2.52.5/2.52.5/2.57.5/7.530/30
400 V5/55/55/57.5/7.530/30
380 V5/55/55/57.5/7.530/30
230 V7.5/7.57.5/7.57.5/7.515/1550/50
GB 14048.2
(Icu/Ics)
AC415 V2.5/2.52.5/2.52.5/2.57.5/7.530/30
400 V5/55/55/57.5/7.530/30
380 V5/55/55/57.5/7.530/30
230 V7.5/7.57.5/7.57.5/7.515/1550/50
NK
(Icu/Ics)
AC450 V2.5/2.52.5/2.52.5/2.57.5/7.525/25
240 V7.5/7.57.5/7.57.5/7.515/1550/50
Rated Impulse Withstand Voltage Uimp (kV)88888
Circuit Breakers Current TypeACACACACAC
Isolation CompatibilityCompatibleCompatibleCompatibleCompatibleCompatible
Reverse ConnectionPossiblePossiblePossiblePossiblePossible
Open-close Lifespan (Cycles)Mechanical10,00010,00010,00015,00025,000
Electrical (440 V AC)6,0006,0006,0008,00010,000
Selectability Type (Usage Category)AAAAA
Degree of Contamination33333
EMC Environmental Conditions (Environment A or Environment B)N/AN/AN/AN/AN/A
External
Dimensions
(mm)

a7575757590
b130130130130130
c6868686868
ca9090909090
Product Weight of Front Surface Type (kg)0.650.650.650.71.0
Electrical Appliance and Material Safety ActCompatibleCompatibleCompatibleCompatibleCompatible
CE MarkSelf-declaredSelf-declaredSelf-declaredSelf-declaredSelf-declared
CCC CertificationCertifiedCertifiedCertifiedCertifiedCertified
Classification Society Certification (✓ = Acquired) (NK, LR, ABS, DNV/GL)
Overcurrent Tripping MethodThermal - electromagneticThermal - electromagneticThermal - electromagneticThermal - electromagneticThermal - electromagnetic
Trip Button

Note 1: The rated capacity applicable to the motor is not stated on the Circuit Breakers. It should be selected according to the full-load current of the motor.
Note 2: Please specify "FP-LT" for flush type with lead terminal block.
Note 3: Please specify "P-LT" for plug-in type with lead terminal block.

External Dimensions of Circuit Breakers

External dimensions

Rated Capacity for MITSUBISHI Circuit Breakers

Circuit Breakers NF32-SV (Frame A: 30)

A200/220 V400/440 V
kWkW
255.511
163.77.5
12-5.5
102.2-
8-3.7
7.11.5-
5-2.2
40.751.5

Circuit Breakers NF63-CV

A200/220 V400/440 V
kWkW
451122
40-18.5
327.515
255.511
163.77.5
12-5.5
102.2-
8-3.7

Circuit Breakers NF32-SV (Frame A: 32)

A200/220 V400/440 V
kWkW
327.515

Circuit Breakers NF63-SV

A200/220 V400/440 V
kWkW
7.11.5-
5-2.2
40.751.5

Circuit Breakers NF125-SV

A200/220 V400/440 V
kWkW
100-55
902245
7118.537
631530
451122
(40)-19
327.515
(25)5.511
(16)3.77.5
(12.5)-5.5

Rated current: A
Rated capacity for Circuit Breakers: kW
Standard ambient temperature: 40°C (45°C for ships)

Part Number
NF63-CVF 3P 40A
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSAmpere frame Rated block capacity AC 200 V
(kA)
Rated block capacity AC 400 V
(kA)
Rated Braking Capacity at Rated Voltage of VDC 250
(kA)
Number of Poles Rated Current
(A)
Representative Standard Dimension height
(mm)
Dimension width
(mm)
Format

MYR 99,999.00

1 Piece(s) Quote 650AF7.55-340PSE / CE / TUV / CCC10054Economical Products

Loading...

  1. 1
 

Basic Information

Mounting Method DIN/Screw retention Connection Method Surface type Dimension depth(mm) 90

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)