(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Our website upgrade are completed! Latest improvements are now LIVE to enhance your ordering experience. You may be logged out due to the update. Please take note to login again or reset credentials if needed. More details here. 

Factory automation endurance robot cable KDF Series (UL standard) (KDF-0.2SQ-3P-9)

Factory automation endurance robot cable KDF Series (UL standard) KDF-0.2SQ-3P-9

300V UL movable signal cable

[Features]
· Fluororesin insulation / bending-resistant.
· Heat resistant.
· Sheath matte finish.
▪ UL/cUL standard cable

PDF

Japanese Only

Part Number

Configured Part Number is shown.

KDF-0.2SQ-3P-9

Product Feature Details

[Features]

  • Fluoropolymer insulation, Flex-resistant
  • Heat resistance
  • Sheath matte
  • UL, cUL standard cable
  • CE applicable, NFPA70, NFPA79 applicable (UL444: CM)

[Applications]

  • Wiring to cable carrier
  • Wiring for the rotating part of the robot arm
 

Product Specifications

< Main Specifications >

Sheath color: Black
Standard: ULAWM2517/ULAWM2103/C-UL/CM
Rated voltage: 300 V
Operating temperature range: 0 to 105°C
Flame retardancy: VW-1
Bending radius: finished outer diameter × 4 (fixed part)
(mm) finished outer diameter × 7.5 (movable part)
*These are recommended values, not guaranteed values.
Product Name
Items
KDF
0.2 mm20.3 mm2, 0.5 mm2
ConductorTin-plated annealed copper bunched wireTin-plated annealed copper composite stranded wire
InsulatorFluoropolymer (ETFE)
Twisted pairWire cores twisted in pairs
TwistedStranded twisted pair wire cores in a round shape
TapeWound with multiple layers of tape
Shield-
SheathOil- and heat-resistant vinyl mixture (black)
 

Technical Information & Design Ideas

Cable typeUL CM (UL 444)cUL CMUL AWM (UL 758)cUL AWM
CMSTYLE 2103STYLE 2517AWM
Compatible sizeAll sizes1P, Type AType B or moreAll sizes
Rated voltage-300V
Rated temperature105℃
Test voltage2,000 V AC/1 min
Flame retardancyVertical-Tray Flame TestFT2VW-1FT2: Type A or fewer
FT1: Type B or more
Compatible standardsUL 444 CSA C22.2 No. 214UL 758CSA C22.2 No. 210

The Electrical Appliances and Materials Safety Act of Japan does not apply to the KDF series, so please use it for low current circuits such as signal and communication circuits.

Specifications Table

ConductorInsulationNumber of coresUnshieldedElectrical Characteristics
Nominal cross-sectional areaOuter diameter (approx. mm)
[Configuration]
Outer diameter (approx. mm)Sheath outer diameter
(approx. mm)
Approximate Weight
(kg/km)
Allowable current
(A)
Conductor resistance
20°C (Ω/km)
Insulation Resistance
(MΩ·km)
0.2 mm2
<25AWG>
0.6
<40/0.08>
1.01P3.5166105 or less1,500 or more
2P5.7355
3P6.2454
4P6.4504
5P7.2604
6P7.7704
7P8.0804
8P8.8903
10P10.01103
12P11.51353
15P11.01403
20P12.01852
0.3 mm2
<23AWG>
0.8
<3/20/0.08>
1.31P4.121871.5 or less1,500 or more
2P6.8507
3P7.3606
4P8.1755
5P8.7855
6P9.51005
8P11.01304
10P12.51704
12P14.52154
15P14.02204
0.5 mm2
<21AWG>
1.1
<3/33/0.08>
1.61P4.7281143.4 or less1,500 or more
2P7.9659
3P8.9858
4P9.81107
5P11.01307
6P12.01507
8P13.52006
10P16.02756
12P17.53206
15P17.03355
20P19.54455

Product Properties

Characteristic diagram of factory automation endurance robot cable KDF Series

Characteristic diagram label 2KDF▶Characteristic Diagram Label 1◀KDF-SB

Operating temperature range

Fixed: -40 to 105°C *
During operation: 0 to 105°C
*When using below 0°C, please ensure that no external forces such as impact, bending, or vibration are applied.

Bending radius

Fixing: Recommended to be at least 4 times the cable outer diameter
During operation: Recommended to be at least 7.5 times the cable outer diameter

About allowable current

The allowable current value is the calculated value when the ambient temperature is 30°C and a single cable is laid in the air. It is not a guaranteed value.
For ambient temperatures above 30℃, multiply the values in the table by the following current reduction factors:
The allowable current value is a value calculated according to JCS0168 and is not a guaranteed value.
JCS0168: The Japanese Electric Wire & Cable Makers' Association standard "Calculation of allowable current for power cable of 33 kV or less"

Current Reduction Factor

Ambient temperature (℃)3035404550556065707580859095100
Current Reduction Factor1.000.970.930.890.860.820.770.730.680.630.580.520.450.360.26

Wire Core Identification

Arrangement Example

Arrangement diagram of factory automation endurance robot cable KDF Series

Wire Core Identification Table

Pair Number1234567810121520
Wire Core NumberL1L2L1L2L1L2L1L2L1L2L1L2L1L2L1L2L1L2L1L2L1L2L1L2
Insulator ColorBlueWhiteYellowBrownGreenBlackRedGrayPurpleOrangeBlueBrownYellowBlackGreenGrayPurpleWhiteYellowGrayPurpleBrownPurpleGray

Arrangement diagram

Arrangement diagram of factory automation endurance robot cable KDF Series

Structure

Structural diagram of factory automation endurance robot cable KDF Series

A: Conductor  B: Tape  C: Insulator  D: Sheath

Structure of twisted pair wire core

Structural diagram of twisted wire core for factory automation endurance robot cable KDF Series

Instructions / Usage Examples

Application example diagram of factory automation endurance robot cable KDF Series

Applications

  • Wiring to cable carrier
  • Wiring for the rotating part of the robot arm
Part Number
KDF-0.2SQ-3P-9
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Logarithm Finished outer diameter
(mm)

MYR 464.87

1 Piece(s) 10 Day(s) or more 90.22563P6.2

Loading...

  1. 1
 

Basic Information

Rated Voltage 300V(UL/cUL), 100/100V(CE) Shield NA Properties Oil Resistance / Heat-Resistance / Flex Resistance
Representative Standard UL / CE / CSA(c-UL) Sheath (outer coating) color Black Grounding Wire NA
Sheath (outer coating) material PVC (PVC) Insulation body materials Fluorine-Based

Please check the type/dimensions/specifications of the part KDF-0.2SQ-3P-9 in the Factory automation endurance robot cable KDF Series (UL standard) series.

Products like this...

Part Number
KDF-0.2SQ-10P-11
KDF-0.2SQ-10P-12
KDF-0.2SQ-10P-13
KDF-0.2SQ-3P-90
KDF-0.2SQ-3P-91
KDF-0.2SQ-3P-92
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Logarithm Finished outer diameter
(mm)

MYR 2,569.45

1 Piece(s) 13 Day(s) or more 110.2252010P10

MYR 2,803.07

1 Piece(s) 13 Day(s) or more 120.2252010P10

MYR 3,036.64

1 Piece(s) 13 Day(s) or more 130.2252010P10

MYR 4,290.73

1 Piece(s) 10 Day(s) or more 900.22563P6.2

MYR 4,338.42

1 Piece(s) 10 Day(s) or more 910.22563P6.2

MYR 4,386.07

1 Piece(s) 10 Day(s) or more 920.22563P6.2

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)