[Features]
· Push-lock type knob allows for easy fixing and pressure adjustment operation with one hand
· Ideal for preventing loosening of the lock nut due to machine vibration, etc.
· New structure increases flow rate by approximately 1.3 times compared to existing products. Further reduction in pressure fluctuation range
· Equipped with a relief mechanism convenient for equipment adjustment
· Equipped with a backflow mechanism. Can be installed between the solenoid valve and actuator and used as a check-type regulator.
· A type with a pressure gauge is also available.

Unit: mm
| Type | Tube outer diameter ⌀D | R | A | B | L1 | L2 | L3 | ⌀p1 | ⌀p2 | ||
| Max. | Min. | Max. | Min. | ||||||||
| RVCP4-M5 | 4 | M5 x 0.8 | 3 | 70 | 67.4 | 67 | 64.4 | 24.2 | 8.5 | 11.5 | 15 |
| RVCP4-01 | R1/8 | 8 | 71.5 | 68.9 | 67.5 | 64.9 | 24.7 | 9 | |||
| RVCP6-M5 | 6 | M5 x 0.8 | 3 | 70 | 67.4 | 67 | 64.4 | 24.2 | 8.5 | 11.5 | 15 |
| RVCP6-01 | R1/8 | 8 | 71.5 | 68.9 | 67.5 | 64.9 | 24.7 | 9 | |||
| RVCP6-02 | R1/4 | 11 | 78.2 | 75.6 | 72.2 | 69.6 | 29 | 11 | 15.5 | 19 | |
| RVCP8-01 | 8 | R1/8 | 8 | 71.5 | 68.9 | 67.5 | 64.9 | 24.7 | 9 | 15.5 | 15 |
| RVCP8-02 | R1/4 | 11 | 78.2 | 75.6 | 72.2 | 69.6 | 29 | 11 | 19 | ||
Unit: mm
| Type | Tube stop C | E1 | E2 | Width across flats H | K | Release ring | Weight (g) | ||
| ⌀Z | X | Y | |||||||
| RVCP4-M5 | 11 | 20.7 | 8.5 | 14 | 6 | - | 9.8 | 7.8 | 26 |
| RVCP4-01 | 5 | ||||||||
| RVCP6-M5 | 11.6 | 21.1 | 8.5 | 14 | 6 | - | 11.8 | 9.8 | 26 |
| RVCP6-01 | 5 | ||||||||
| RVCP6-02 | 17 | 29.8 | 10.5 | 17 | 6 | 11.8 | - | - | 46 |
| RVCP8-01 | 18.1 | 27.7 | 8.5 | 14 | 5 | 13.8 | - | - | 29 |
| RVCP8-02 | 29.7 | 10.5 | 17 | 6 | 46 | ||||

Unit: mm
| Type | Tube outer diameter ⌀D | R | A | B | L1 | L2 | L3 | L4 | ⌀p1 | ⌀p2 | ||
| Max. | Min. | Max. | Min. | |||||||||
| RVCMP4-M5 | 4 | M5 x 0.8 | 3 | 70 | 67.4 | 67 | 64.4 | 48.7 | 24.2 | 8.5 | 11.5 | 15 |
| RVCMP4-01 | R1/8 | 8 | 71.5 | 68.9 | 67.5 | 64.9 | 49.2 | 24.7 | 9 | |||
| RVCMP6-M5 | 6 | M5 x 0.8 | 3 | 70 | 67.4 | 67 | 64.4 | 48.7 | 24.2 | 8.5 | 11.5 | 15 |
| RVCMP6-01 | R1/8 | 8 | 71.5 | 68.9 | 67.5 | 64.9 | 49.2 | 24.7 | 9 | |||
| RVCMP6-02 | R1/4 | 11 | 78.2 | 75.6 | 72.2 | 69.6 | 56.3 | 29 | 11 | 15.5 | 19 | |
| RVCMP8-01 | 8 | R1/8 | 8 | 71.5 | 68.9 | 67.5 | 64.9 | 52 | 24.7 | 9 | 15.5 | 15 |
| RVCMP8-02 | R1/4 | 11 | 78.2 | 75.6 | 72.2 | 69.6 | 56.3 | 29 | 11 | 19 | ||
Unit: mm
| Type | Tube stop C | E1 | E2 | E3 | Width across flats H | K | Release ring | Weight (g) | ||
| ⌀Z | X | Y | ||||||||
| RVCMP4-M5 | 11 | 26.3 | 8.5 | 16.2 | 14 | 6 | - | 9.8 | 7.8 | 29 |
| RVCMP4-01 | 5 | |||||||||
| RVCMP6-M5 | 11.6 | 26.7 | 8.5 | 16.2 | 14 | 6 | - | 11.8 | 9.8 | 29 |
| RVCMP6-01 | 5 | |||||||||
| RVCMP6-02 | 17 | 30 | 10.5 | 17.7 | 17 | 6 | 11.8 | - | - | 49 |
| RVCMP8-01 | 18.1 | 28.4 | 8.5 | 16.2 | 14 | 5 | 13.8 | - | - | 31 |
| RVCMP8-02 | 29.9 | 10.5 | 17.7 | 17 | 6 | 49 | ||||

Unit: mm
| Type | Tube outer diameter ⌀D1 | Tube outer diameter ⌀D2 | B | L1 | L2 | L3 | ⌀p1 | ⌀p2 | ⌀p3 | Tube stop C1 | Tube stop C2 | E1 | E2 | |
| Max. | Min. | |||||||||||||
| RVUP4-4 | 4 | 4 | 61.6 | 59 | 13 | 18.8 | 1 | 11.5 | 11.5 | 15 | 11 | 11 | 21.6 | 21.6 |
| RVUP6-4 | 6 | 4 | 61.6 | 59 | 13 | 18.8 | 1 | 11.5 | 11.5 | 15 | 11.6 | 11 | 22 | 21.6 |
| RVUP6-6 | 6 | 11.6 | 22 | |||||||||||
| RVUP8-6 | 8 | 6 | 65.7 | 63.1 | 15 | 22.5 | - | 15.5 | 15.5 | 19 | 18.1 | 17 | 28.6 | 28.7 |
| RVUP8-8 | 8 | 18.1 | 28.6 | |||||||||||
Unit: mm
| Type | F1 | F2 | F3 | F4 | F5 | F6 | F7 | T1 | T2 | Release ring | Weight (g) | |||||
| ⌀Z1 | X1 | Y1 | ⌀Z2 | X2 | Y2 | |||||||||||
| RVUP4-4 | 15 | 30 | 4.2 | 17 | 10.3 | 20.6 | 8 | 24.5 | 15 | - | 9.8 | 7.8 | - | 9.8 | 7.8 | 19 |
| RVUP6-4 | 15 | 30 | 4.2 | 17 | 10.3 | 20.6 | 9 | 24.5 | 15 | - | 11.8 | 9.8 | - | 9.8 | 7.8 | 20 |
| RVUP6-6 | 11.8 | 9.8 | ||||||||||||||
| RVUP8-6 | 19.8 | 39.6 | 4 | 21.5 | 11.7 | 23.4 | 13 | 28.4 | 19 | 13.8 | - | - | 11.8 | - | - | 32 |
| RVUP8-8 | 13.8 | 33 | ||||||||||||||

Unit: mm
| Type | Tube outer diameter ⌀D1 | Tube outer diameter ⌀D2 | B | L1 | L2 | L3 | L4 | ⌀p1 | ⌀p2 | ⌀p3 | Tube stop C1 | Tube stop C2 | E1 | E2 | |
| Max. | Min. | ||||||||||||||
| RVUMP4-4 | 4 | 4 | 61.6 | 59 | 43.3 | 13 | 18.8 | 1 | 11.5 | 11.5 | 15 | 11 | 11 | 21.6 | 30.6 |
| RVUMP6-4 | 6 | 4 | 61.6 | 59 | 43.3 | 13 | 18.8 | 1 | 11.5 | 11.5 | 15 | 11.6 | 11 | 22 | 30.6 |
| RVUMP6-6 | 6 | 11.6 | 31 | ||||||||||||
| RVUMP8-6 | 8 | 6 | 65.7 | 63.1 | 49.8 | 15 | 22.5 | - | 15.5 | 15.5 | 19 | 18.1 | 17 | 28.6 | 33 |
| RVUMP8-8 | 8 | 18.1 | 32.9 | ||||||||||||
| RVUMP1/4-1/4 | 1/4 | 1/4 | 61.6 | 59 | 43.3 | 13 | 18.8 | 1 | 11.5 | 11.5 | 15 | 11.4 | 11.4 | 22.2 | 31.2 |
Unit: mm
| Type | F1 | F2 | F3 | F4 | F5 | F6 | F7 | F8 | T1 | T2 | Release ring | Weight (g) | |||||
| ⌀Z1 | X1 | Y1 | ⌀Z2 | X2 | Y2 | ||||||||||||
| RVUMP4-4 | 15 | 30 | 4.2 | 17 | 10.1 | 20.2 | 10.2 | 9 | 24.5 | 15 | - | 9.8 | 7.8 | - | 9.8 | 7.8 | 23 |
| RVUMP6-4 | 15 | 30 | 4.2 | 17 | 10.1 | 20.2 | 10.2 | 9 | 24.5 | 15 | - | 11.8 | 9.8 | - | 9.8 | 7.8 | 23 |
| RVUMP6-6 | 11.8 | 9.8 | |||||||||||||||
| RVUMP8-6 | 19.9 | 39.7 | 4.1 | 21.3 | 11.6 | 23.2 | 9.1 | 13 | 28.4 | 19 | 13.8 | - | - | 11.8 | - | - | 36 |
| RVUMP8-8 | 13.8 | ||||||||||||||||
| RVUMP1/4-1/4 | 15 | 30 | 4.2 | 17 | 10.1 | 20.2 | 10.2 | 9 | 24.5 | 15 | - | 11.8 | 9.8 | - | 11.8 | 9.8 | 23 |
| Tube size | Metric size | Inch size |
|---|---|---|
| Operating fluid | Air | |
| Operating pressure range | 0-1.0 MPa | 0 to 145 psi |
| Set pressure range | 0.1-0.8 MPa | 14.5-116 psi |
| Indicated pressure range | 0 to 0.8 MPa | 0 to 116 psi |
| Accuracy (gauge) | +/- 5% (F.S) | |
| Operating temperature range | 0 to 60℃ (no freezing) | |

1. Adjusting the pressure
Release the lock by pulling the regulating knob upward before adjusting the pressure.
Do not apply more force than necessary to the pressure regulating knob at this time. This may cause damage.

2. When increasing the pressure
Turn the regulating knob clockwise from the fully open position to increase the pressure.
Once the desired pressure is reached, be sure to press the regulating knob and lock it to prevent the set pressure from changing.
3. Decreasing the pressure
If the regulating knob is turned too far (if the pressure is too high), turning it counterclockwise will activate the relief mechanism and decrease the pressure.
Following this, adjust as described in "2. Increasing the pressure."
Once the desired pressure is reached, be sure to press the adjustment knob and lock it to prevent the set pressure from changing.

1. Do not use the regulator in such a way that the pressure exceeds the preset level due to large pressure fluctuations on the outlet side. This product is not designed as a relief valve, and using it as one may cause equipment damage or malfunction. In such cases, please install a separate safety device before use.
1. Perform the pressure setting by turning the regulating knob in the upward direction (clockwise). The pressure cannot be set accurately if the regulating knob is turned in the downward direction (counterclockwise).
2. Do not turn the regulating knob counterclockwise from a fully open position, or too far clockwise from a fully closed position. Doing so may damage the regulating knob or the main body. It can also increase the torque on the regulating knob due to the sticking of the regulating screw and regulating nut.
3. The regulating knob locks when pushed down and releases when pulled up. After adjusting, be sure to set it to the locked position. Failure to lock the knob means the knob may turn, causing the pressure to change.
4. When you press down the regulating knob, it can sometimes stop partway between the locked and unlocked positions depending on how far round it is rotated. When this happens, the knob is not completely locked. Please ensure that the regulating knob is fully pushed down to the locked position.
5. Trying to force the knob to turn while it is in the locked position may cause damage to the lock mechanism.
6. For models with a gauge, the gauge can be oriented in any direction. Applying excessive force to the gauge cap can result in damage to the gauge and cause issues with gauge readings. Please hold the gauge close to the base when turning it.
7. The pressure gauge accuracy is +/- 5% (FS). If greater accuracy is required, please check the pressure using a separate pressure gauge and adjust accordingly.
8. When open air is released from the outlet, the flow rate may cause resonance. Avoid releasing open air on the outlet for prolonged periods of time, as this poses a risk of internal damage or other issues.
| Part Number |
|---|
| RVCMP6-02 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Shape | Supply Side, Connection Type | Supply Side, Connection Dia. | Control Side, Connection Dia. | Pressure Gauge |
|---|---|---|---|---|---|---|---|---|---|
MYR 144.99 | 1 Piece(s) | Available | 13 Day(s) or more | [Single-Action Fitting Type] One-Touch Coupling Type Elbow with Gauge | R | 1/4 | φ6 | With Gage |
Loading...
| Regulator, Pressure Boosting Valve | Regulator | Regulator Type | With Check valve | Applicable Fluid | Air |
|---|---|---|---|---|---|
| Operating Environment | Standard | Set Pressure Range(MPa) | 0.1~0.8 | Exhaust Mechanism | Presence |
| Adverse Current Function | Presence | Operating Pressure Range(MPa) | 0:: 1.0 | Control Side, Connection Type | One-Touch |
Please check the type/dimensions/specifications of the part RVCMP6-02 in the Regulator Push-Lock Type series.
| Part Number |
|---|
| RVCMP4-01 |
| RVCMP4-M5 |
| RVCMP6-01 |
| RVCMP6-M5 |
| RVCMP8-01 |
| RVCMP8-02 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Shape | Supply Side, Connection Type | Supply Side, Connection Dia. | Control Side, Connection Dia. | Pressure Gauge |
|---|---|---|---|---|---|---|---|---|---|
MYR 130.31 | 1 Piece(s) | Available | 15 Day(s) or more | [Single-Action Fitting Type] One-Touch Coupling Type Elbow with Gauge | R | 1/8 | φ4 | With Gage | |
MYR 118.38 | 1 Piece(s) | Available | 15 Day(s) or more | [Single-Action Fitting Type] One-Touch Coupling Type Elbow with Gauge | Others | M5 | φ4 | With Gage | |
MYR 137.74 | 1 Piece(s) | Available | 15 Day(s) or more | [Single-Action Fitting Type] One-Touch Coupling Type Elbow with Gauge | R | 1/8 | φ6 | With Gage | |
MYR 124.26 | 1 Piece(s) | Available | 18 Day(s) or more | [Single-Action Fitting Type] One-Touch Coupling Type Elbow with Gauge | Others | M5 | φ6 | With Gage | |
MYR 142.15 | 1 Piece(s) | Available | 15 Day(s) or more | [Single-Action Fitting Type] One-Touch Coupling Type Elbow with Gauge | R | 1/8 | φ8 | With Gage | |
MYR 150.87 | 1 Piece(s) | Available | 15 Day(s) or more | [Single-Action Fitting Type] One-Touch Coupling Type Elbow with Gauge | R | 1/4 | φ8 | With Gage |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy