Fiber Coaxial Displacement Sensor [ZW-8000/7000/5000]

Part Number

Configured Part Number is shown.

Dimensional Drawing

Sensor Head

Rectangular Straight Type

Fiber Coaxial Displacement Sensor [ZW-8000/7000/5000] Sensor Head Rectangular Straight Type External Dimensions
*1
*2
Part numberW.D.M
Model ZW-S8010100.5
Model ZW-S8020201
Model ZW-S8030302
Length specificationsL
0.3 m(300)
2M(2,000)

*Please refer to the digital catalog for information on part numbers other than those listed above.

Product Specifications

Ratings/Performance

Sensor Controller

ItemSpecifications
Model ZW-8000□Model ZW-7000□Model ZW-5000□
Input/Output TypeNPN/PNP Compatible
Number of Sensor Heads Connectable1 unit
Compatible Sensor HeadsModel ZW-S80□□/
ZW-SP80□□/
ZW-SPR80□□
Model ZW-S70□□/
ZW-SP70□□/
ZW-SPR70□□
ZW-S50□□/
ZW-SP50□□/
ZW-SPR50□□
LED SafetyRisk Group 3 (IEC62471)
Segment DisplayMain Digital Display11-segment white display, 6 digits
Sub Digital Display11-segment green display, 6 digits
Indicator LightStatus Indicator LightHIGH (orange), PASS (green), LOW (orange), STABILITY (green), ZERO (green),
ENABLE (green), THRESHOLD-H (orange), THRESHOLD-L (orange), RUN (green)
EtherCAT IndicatorsECAT RUN (green), L/A IN (Link/Activity IN) (green),
L/A OUT (Link/Activity OUT) (green), ECAT ERR (red)
External
Interface
Ethernet100BASE-TX/10BASE-T No Procedure (TCP/UDP), EtherNet/IP
EtherCATEtherCAT Dedicated Protocol 100BASE-TX
RS-232CUp to 115,200 bps
Analog
Output Terminal Block
Analog Voltage Output (OUTV)-10 V to +10 V, Output impedance: 100 Ω
Analog Current Output (OUTA)4 mA to 20 mA, Maximum load resistance: 300 Ω
32-Pin Expansion
Connector
Judgment Output
(HIGH/PASS/LOW)
Transistor output type
Output voltage: DC 21.6–30 V
Load current: 50 mA or less
ON-State Residual Voltage: 2 V or less
OFF-State Leakage Current: 0.1 mA or less
Busy Output (BUSY)
Alarm Output (ALARM)
Enable Output (ENABLE)
Sync Flag Output (SYNFLG)
Trigger Busy Output
(TRIGBUSY)
Logging State Output
(LOGSTAT)
Logging Error Output
(LOGERR)
Stability output
(STABILITY)
Task state output
(TASKSTAT)
LIGHT off input (LIGHT OFF)DC input method
Input voltage: 24 V DC ±10% (DC 21.6–26.4 V)
Input current: 7 mA Typ. (24 V DC)
ON voltage/ON current: 19 V/3 mA or more
OFF voltage/OFF current: 5 V/1 mA or less
Zero reset input (ZERO)
Timing input (TIMING)
Reset input (RESET)
Sync Input (SYNC)
Trigger Input (TRIG)
Logging Input (LOGGING)
BankSelected
Bank Output
(BANK_
OUT 1–3)
Transistor output type
Output voltage: DC 21.6–30 V
Load current: 50 mA or less
ON-State Residual Voltage: 2 V or less
OFF-State Leakage Current: 0.1 mA or less
Bank
Selection Input
(BANK_
SEL 1–3)
DC input method
Input voltage: 24 V DC ±10% (DC 21.6–26.4 V)
Input current: 7 mA Typ. (24 V DC)
ON voltage/ON current: 19 V/3 mA or more
OFF voltage/OFF current: 5 V/1 mA or less
ItemSpecifications
Model ZW-8000□Model ZW-7000□Model ZW-5000□
Main FunctionsExposure TimeAuto/Fixed
Measurement Cycle *160µs–7,500µs20µs–400µs80µs–1,600µs
Material SpecificationStandard/Mirror/Rough
Measurement ItemsHeight/Thickness/Calculation
Filter ProcessingMedian/Average/Differentiation/High-pass/Low-pass/Band-pass
OutputScaling / Various Hold Functions / Zero Reset / Measurement Value Logging / Keep & Clamp
DisplayMeasurement Value / Threshold / Analog Output Voltage or Current Value / Judgment Result / Resolution
Light Emission Amount / Internal Logging Status / Peak Received Light Amount
Number of Setting RegistrationsStandard Mode: Up to 8 banks
Judgment Value Mode: Up to 32 banks
Task ProcessingMultitasking (up to 4 tasks per bank)
SystemSave/Initialize/Display Measurement Information/Communication Settings/Sensor Head Calibration/Key Lock/Zero Reset Memory/Timing Input
Rated conditionsPower Supply Voltage21.6 to 26.4 V DC (Including Ripple)
Current Consumption700 mA or less800 mA or less
Insulation ResistanceBetween all lead wires and FG terminal: 20 MΩ (by 250 V insulation resistance tester)
Withstand VoltageBetween all lead wires and FG terminal: 500 V AC, 50/60 Hz, 1 min.
Environmental ProtectionProtective StructureIP20 (IEC60529)
Vibration (durability)10 to 55 Hz (0.35 mm single amplitude), 50 min in each direction of X, Y, and Z
Shock (durability)150 m/s2, 3 times in each of 6 directions (up/down, left/right, front/back)
Ambient Temperature RangeOperating: 0 to 40°C, Storage: -15 to +60°C
(no freezing or condensation)
Ambient Humidity RangeDuring operation/storage: 35 to 85% RH (no condensation)
GroundType D grounding (grounding resistance 100Ω or less) *Formerly known as Type 3 grounding
MaterialCase: PC
MassApproximately 950 g (main body only),
approximately 150 g (parallel cable)
Approximately 900 g (main body only), approximately 150 g (parallel cable)
AccessoryParallel Cable: 1 piece (Model ZW-XCP2E),
Fiber Cleaner: 10 pieces (Model ZW-XCL),
Instruction Manual, Membership Registration Sheet, Precautions for Use
Parallel Cable:
1 piece (Model ZW-XCP2E),
Fiber Cleaner:
10 Fiber Cleaners (Model ZW-XCL),
Fiber Adapter Cap:
1 piece,
Strap: 1 piece,
Instruction Manual,
Membership Registration Sheet,
Precautions for Use

Note: Sensor controllers compliant with the Export Trade Control Order (Models ZW-8000T/7000T/5000T) are available.
When using this sensor controller, the minimum resolution will be 0.25 µm regardless of the connected sensor head or configuration settings.
*1. When an extension fiber cable of 2 m or longer is connected to the ZW-8000 Series, 10 m or longer to the ZW-7000 Series, or 5 m or longer to the ZW-5000 Series, the setting range for the measurement cycle (exposure time)
will change. For details, please refer to "Setting the Measurement Cycle" in the ZW-8000/7000/5000 User's Manual (SCEA-702).

Sensor Head

ZW-S8010/S8020/S8030/SP8007/SP8010/SPR8007/SPR8010

ItemModel
Model ZW-S8010Model ZW-S8020Model ZW-S8030Model ZW-SP8007Model ZW-SP8010Model ZW-SPR8007Model ZW-SPR8010
Applicable Sensor ControllerModel ZW-8000□
Sensor Head TypeRectangular Straight TypePen-type Straight TypePen-type Right Angle Type
Measurement Center Distance *110 mm20 mm30 mm7 mm10 mm7 mm10 mm
Measurement Range *2±0.5 mm±1 mm±2 mm±0.3 mm±0.7 mm±0.3 mm±0.7 mm
Static Resolution *30.002µm0.004µm0.008µm0.002µm0.003µm0.003µm0.005 µm
Linearity *4±0.3 µm±0.6 µm±1.3 µm±0.3 µm±0.45 µm±0.45 µm±0.7 µm
Spot diameter
(Entire measurement range) *5
⌀4 µm⌀7 µm⌀10 µm⌀7 µm⌀10 µm⌀8µm⌀11µm
Measurement cycle *660µs–7,500µs
Operating Ambient LuminosityObject surface illuminance 30,000 lx or less: incandescent lamp
Ambient Temperature RangeOperating: 0 to 50°C, Storage: -15 to +60°C (No freezing or condensation)
Ambient Humidity RangeOperating/Storage: 35 to 85% RH (no condensation)
Protective StructureIP40 (IEC60529)
Vibration (durability)10–150 Hz (single amplitude 0.35 mm), 80 minutes in each of the X/Y/Z directions
Shock (durability)150 m/s2, 6 directions, 3 times each (up/down, left/right, front/back)
Temperature characteristics *70.6 µm/°C
(0.2 µm/°C)
1.1 µm/°C
(0.5 µm/°C)
1.8 µm/°C
(1.0 µm/°C)
0.8 µm/°C
(0.4 µm/°C)
0.8 µm/°C
(0.4 µm/°C)
0.8 µm/°C
(0.4 µm/°C)
0.8 µm/°C
(0.4 µm/°C)
LED SafetyRisk Group 3 (IEC62471)
MaterialChassis: Die-cast aluminum
Fiber cable sheath: PVC
Calibration ROM: PC
Chassis: SUS
Fiber cable sheath: PVC
Calibration ROM: PC
Mounting Plate: Aluminum
Chassis: SUS, aluminum
Fiber cable sheath: PVC
Calibration ROM: PC
Mounting Plate: Aluminum
Fiber cable length0.3 m, 2 m (flexible cable)
Fiber cable minimum bending radius20 mm
Insulation Resistance
(Calibration ROM)
Between case and all terminals: 20 MΩ (by 250 V insulation resistance tester)
Withstand Voltage
(Calibration ROM)
Between case and all terminals: 1000 V AC, 50/60 Hz, 1 min.
MassFiber cable length 0.3 m: Approximately 170 g
Fiber cable length 2 m: Approximately 180 g
Fiber cable length 0.3 m:
Approximately 27 g
Fiber cable length 2 m:
Approximately 37 g
Fiber cable length 0.3 m:
approx. 31 g
Fiber cable length 2 m:
approx. 41 g
AccessoryCalibration ROM fixing screw
(M2 × 5 mm): 1 piece, fiber protection cap: 1 piece,
strap: 1 piece, instruction manual, safety precautions
Mounting plate: 1 piece, main unit fixing screws (M2 × 10 mm): 4 pieces,
calibration ROM fixing screw (M2 × 5 mm): 1 piece,
fiber protection cap: 1 piece, strap: 1 piece,
instruction manual, safety precautions

*1. Indicates the distance from the front of the sensor head. For the pen-type right angle model, there may be an individual variation of up to ±0.15 mm in the distance from the front of the sensor head.
*2. The measurement range applies when the measurement cycle is 100 µs or longer.
*3. Actual value when measuring Omron's standard mirror target at the center measurement distance with an average of 16,384 times.
When connected to an export control trade regulation compliant sensor controller (Model ZW-8000T), the minimum resolution is 0.25 µm regardless of the sensor head or setting conditions.
*4. Error relative to the ideal straight line when measuring Omron's standard mirror target with material setting: mirror
*5. Actual value defined as 1/e2 (13.5%) of the peak light intensity at the measurement wavelength
*6. When a fiber extension cable of 2 m or longer is connected, the setting range for the measurement period (exposure time) will change.
For details, please refer to "Setting the Measurement Cycle" in the ZW-8000/7000/5000 User's Manual (SCEA-702).
*7. Actual value of the amount of change in the measured value at the measurement center distance when the space between the sensor head and the target is fixed with an aluminum jig, and the sensor head and sensor controller are installed in the same temperature environment.
Values in parentheses are actual values when using an SUS304 jig.
For thickness measurements, the value is calculated from the difference in height between the front and back surfaces, so it is not affected by temperature changes.

Model ZW-S7010/S7020/S7030/S7040/SP7007/SP7010/SPR7007/SPR7010

ItemModel
Model ZW-S7010Model ZW-S7020Model ZW-S7030Model ZW-S7040Model ZW-SP7007Model ZW-SP7010Model ZW-SPR7007Model ZW-SPR7010
Applicable Sensor ControllerModel ZW-7000□
Sensor Head TypeRectangular Straight TypePen-type Straight TypePen-type Right Angle Type
Measurement Center Distance *110 mm20 mm30 mm40 mm7 mm10 mm7 mm10 mm
Measurement Range *2±0.5 mm±1 mm±2 mm±3 mm±0.3 mm±0.7 mm±0.3 mm±0.7 mm
Static Resolution *30.004µm0.008µm0.016µm0.024µm0.004µm0.006µm0.006µm0.009 µm
Linearity *4±0.45 µm±0.9 µm±2.0 µm±3.0 µm±0.45 µm±0.7 µm±0.7 µm±1.1 µm
Spot diameter
(Entire measurement range) *5
⌀50 µm⌀70 µm⌀100 µm⌀120 µm⌀130 µm⌀170 µm⌀150 µm⌀190 µm
Measurement cycle *620µs–400µs
Operating Ambient LuminosityObject surface illuminance 30,000 lx or less: incandescent lamp
Ambient Temperature RangeOperating: 0 to 50°C, Storage: -15 to +60°C (No freezing or condensation)
Ambient Humidity RangeOperating/Storage: 35 to 85% RH (no condensation)
Protective StructureIP40 (IEC60529)
Vibration (durability)10–150 Hz (single amplitude 0.35 mm), 80 minutes in each of the X/Y/Z directions
Shock (durability)150 m/s2, 6 directions, 3 times each (up/down, left/right, front/back)
Temperature characteristics *70.6 µm/°C
(0.2 µm/°C)
1.1 µm/°C
(0.5 µm/°C)
1.8 µm/°C
(1.0 µm/°C)
2.1µm/°C
(1.2µm/°C)
0.8 µm/°C
(0.4 µm/°C)
0.8 µm/°C
(0.4 µm/°C)
0.8 µm/°C
(0.4 µm/°C)
0.8 µm/°C
(0.4 µm/°C)
LED SafetyRisk Group 3 (IEC62471)
MaterialChassis: Die-cast aluminum
Fiber cable sheath: PVC
Calibration ROM: PC
Chassis: SUS
Fiber cable sheath: PVC
Calibration ROM: PC
Mounting Plate: Aluminum
Chassis: SUS, aluminum
Fiber cable sheath: PVC
Calibration ROM: PC
Mounting Plate: Aluminum
Fiber cable length0.3 m, 2 m (flexible cable)
Fiber Cable
Minimum Bending Radius
20 mm
Insulation Resistance
(Calibration ROM)
Between case and all terminals: 20 MΩ (by 250 V insulation resistance tester)
Withstand Voltage
(Calibration ROM)
Between case and all terminals: 1000 V AC, 50/60 Hz, 1 min.
MassFiber cable length 0.3 m: Approximately 170 g
Fiber cable length 2 m: Approximately 180 g
Fiber cable length 0.3 m:
Approximately 27 g
Fiber cable length 2 m:
Approximately 37 g
Fiber cable length 0.3 m:
approx. 31 g
Fiber cable length 2 m:
approx. 41 g
AccessoryCalibration ROM fixing screw (M2 × 5 mm): 1 piece,
Fiber protection cap: 1 piece, Strap: 2 pieces,
Instruction manual, Safety precautions
Mounting plate: 1 piece, Main unit fixing screws (M2 × 10 mm): 4 pieces,
Calibration ROM fixing screw (M2 × 5 mm): 1 piece,
Fiber protection cap: 1 piece, Strap: 2 pieces,
Instruction manual, Safety precautions

*1. Indicates the distance from the front of the sensor head. For the pen-type right angle model, there may be individual differences of up to ±0.15 mm in the distance from the front of the sensor head.
*2. Measurement range applies when the measurement cycle is 28 µs or longer.
*3. Actual value when measuring Omron's standard mirror target at the measurement center distance with an average of 16,384 times.
When connected to an Export Trade Control Order-compliant sensor controller (Model ZW-7000T), the minimum resolution will be 0.25 µm regardless of the sensor head or configuration settings.
*4. Error relative to the ideal straight line when measuring Omron's standard mirror target with material setting: mirror
*5. Actual value defined as 1/e2 (13.5%) of the peak light intensity at the measurement wavelength
*6. When a fiber extension cable of 10 m or longer is connected, the setting range for the measurement period (exposure time) will change. For details, please refer to "Setting the Measurement Cycle" in the ZW-8000/7000/5000 User's Manual (SCEA-702).

*7. Actual value of the change in measurement at the center distance when the sensor head and the target are fixed with an aluminum jig and both the sensor head and sensor controller are placed in the same temperature environment.
Values in parentheses are actual values when using an SUS304 jig.
For thickness measurements, the value is calculated from the difference in height between the front and back surfaces, so it is not affected by temperature changes.

Model ZW-S5010/S5020/S5030/SP5007/SP5010/SPR5007/SPR5010

ItemModel
Model ZW-S5010Model ZW-S5020Model ZW-S5030Model ZW-SP5007Model ZW-SP5010Model ZW-SPR5007Model ZW-SPR5010
Applicable Sensor ControllerModel ZW-5000□
Sensor Head TypeRectangular Straight TypePen-type Straight TypePen-type Right Angle Type
Measurement center distance*110 mm20 mm30 mm7 mm10 mm7 mm10 mm
Measurement range±0.5 mm±1 mm±2 mm±0.3 mm±0.7 mm±0.3 mm±0.7 mm
Static Resolution *20.004µm0.008µm0.016µm0.004µm0.006µm0.006µm0.009 µm
Linearity *3±0.45 µm±0.9 µm±2.0 µm±0.45 µm±0.7 µm±0.7 µm±1.1 µm
Spot diameter
(Entire measurement range) *4
Approx. 9 µm (round)Approx. 13 µm (round)Approx. 18 µm (round)Approx. 13 µm (round)Approx. 18 µm (round)⌀15 µm⌀20 µm
Measurement cycle *580µs–1,600µs
Operating Ambient LuminosityObject surface illuminance 30,000 lx or less: incandescent lamp
Ambient Temperature RangeOperating: 0 to 50°C, Storage: -15 to +60°C (No freezing or condensation)
Ambient Humidity RangeOperating/Storage: 35 to 85% RH (no condensation)
Protective StructureIP40 (IEC60529)
Vibration (durability)10–150 Hz (single amplitude 0.35 mm), 80 minutes in each of the X/Y/Z directions
Shock (durability)150 m/s2, 6 directions, 3 times each (up/down, left/right, front/back)
Temperature Characteristics *60.6 µm/°C
(0.2 µm/°C)
1.1 µm/°C
(0.5 µm/°C)
1.8 µm/°C
(1.0 µm/°C)
0.8 µm/°C
(0.4 µm/°C)
0.8 µm/°C
(0.4 µm/°C)
0.8 µm/°C
(0.4 µm/°C)
0.8 µm/°C
(0.4 µm/°C)
LED SafetyRisk Group 3 (IEC62471)
MaterialChassis: Die-cast aluminum
Fiber cable sheath: PVC
Calibration ROM: PC
Chassis: SUS
Fiber cable sheath: PVC
Calibration ROM: PC
Mounting Plate: Aluminum
Chassis: SUS, aluminum
Fiber cable sheath: PVC
Calibration ROM: PC
Mounting Plate: Aluminum
Fiber cable length0.3 m, 2 m (flexible cable)
Fiber Cable
Minimum Bending Radius
20 mm
Insulation Resistance
(Calibration ROM)
Between case and all terminals: 20 MΩ (by 250 V insulation resistance tester)
Withstand Voltage
(Calibration ROM)
Between case and all terminals: 1000 V AC, 50/60 Hz, 1 min.
MassFiber cable length 0.3 m: Approximately 170 g
Fiber cable length 2 m: Approximately 180 g
Fiber cable length 0.3 m: approx. 29 g
Fiber cable length 2 m: approx. 39 g
Fiber cable length 0.3 m: approx. 33 g
Fiber cable length 2 m: approx. 43 g
AccessoryCalibration ROM fixing screw
(M2 × 5 mm): 1 piece,
Fiber protection cap: 1 piece, Strap: 1 piece,
Instruction manual, Safety precautions
Mounting plate: 1 piece, Main unit fixing screws (M2 × 10 mm): 4 pieces,
Calibration ROM fixing screw (M2 × 5 mm): 1 piece,
Fiber protection cap: 1 piece, Strap: 1 piece,
Instruction manual, Safety precautions

*1. Indicates the distance from the front of the sensor head. For the pen-type right angle model, there may be an individual variation of up to ±0.15 mm in the distance from the front of the sensor head.
*2. Actual value when Omron's standard mirror target is measured at the measurement center distance with an average of 16,384 measurements.
When connected to an export control compliant sensor controller (Model ZW-5000T), the minimum resolution is 0.25 µm regardless of the sensor head or setting conditions.
*3. Error relative to the ideal straight line when measuring Omron's standard mirror-finish target with material setting: mirror
*4. Actual value defined at 1/e2 (13.5%) of the peak light intensity at the measurement wavelength
*5. When a fiber extension cable of 5 m or longer is connected, the setting range for the measurement period (exposure time) will change. For details, please refer to "Setting the Measurement Cycle" in the ZW-8000/7000/5000 User's Manual (SCEA-702).

*6. Actual value of the change in measurement at the center distance when the sensor head and the target are fixed with an aluminum jig and both the sensor head and sensor controller are placed in the same temperature environment.
Values in parentheses are actual values when using an SUS304 jig.
For thickness measurements, the value is calculated from the difference in height between the front and back surfaces, so it is not affected by temperature changes.

Part Number
ZW-S7020 2M
ZW-S7030 2M
ZW-S7040 2M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipResolution
(μm)
Spot diameter
(µm)

MYR 27,505.58

1 Piece(s) 9 Day(s) or more 0.008⌀70

MYR 27,505.58

1 Piece(s) 9 Day(s) or more 0.016⌀100

MYR 29,491.95

1 Piece(s) 9 Day(s) or more 0.024⌀120

Loading...

  1. 1

Basic Information

Type Displacement Sensor Type | the type of the sensor unit Sensor Head (Rectangular Straight Type) Cable Length(m) 2

Additional Products in this Category

Tech Support