(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Our website upgrade are completed! Latest improvements are now LIVE to enhance your ordering experience. You may be logged out due to the update. Please take note to login again or reset credentials if needed. More details here. 

Smart Fiber Amplifier E3NX-MA

Smart Fiber Amplifier E3NX-MA

A single unit with 2 channels halves the installation space and achieves a compact device and control panel.
[Features]
· Equipped with the functions of 2 units in the size of a general fiber amplifier. Contributes to miniaturization of equipment and control panels
·Basic performance that enables ultra-stable detection from transparent objects to low-reflection workpieces, even with 2 channels
·Easy automatic setting of light intensity and threshold
·Wire saving connector type reduces wiring labor-hours

PDF

Drawing

Pre-wired type

Smart fiber amplifier E3NX-MA, pre-wired type, drawing

Reduced wiring connector type

Smart fiber amplifier E3NX-MA, wire saving connector type, drawing

Connector type for sensor communication unit

Smart fiber amplifier E3NX-MA, connector type for sensor communication unit, drawing

Product Specification

Rating / Performance

ItemsNPN outputModel E3NX-MA11Model E3NX-MA6Model E3NX-MA0
PNP outputModel E3NX-MA41Model E3NX-MA8
Connection methodPre-wiredConnector for simplified wiringConnection connector for sensor communication unit
TypeStandard typeFor sensor communication unit
Input/outputOutput2 output- *1
External input--
Light source (emission wavelength)Red 4-element light emitting diode (625 nm)
Power supply voltage10 to 30 V DC, including 10% ripple (pp)Supplied from the connector
through the sensor communication unit
Power consumption*2At 24 V power supply voltage
Normal mode: 960 mW or less (current consumption: 40 mA or less)
Eco function ON: 770 mW or less (current consumption: 32 mA or less)
Eco function LO: 870 mW or less (current consumption: 36 mA or less)
Control outputLoad power supply voltage: 30 V DC or less, open collector output type
(Depends on NPN/PNP output format)
Load current: 100 mA or less when connecting 1 to 3 units, 20 mA or less when connecting 4 or more units
(residual voltage, less than 10 mA load current: 1 V or less, 10 to 100 mA load current: 2 V or less)
Off-state current: 0.1 mA or less
-
Indicator Light7-segment display (sub-digital display: green, main digital display: white)
Display direction: Normal / reverse display switchable
OUT indicator light (orange), L/D indicator light (orange), ST indicator light (blue), DPC indicator light (green), OUT selection indicator light (orange)
Protection circuitPower supply reverse connection protection, output short circuit protection, output reverse connection protectionPower supply reverse connection protection,
output short circuit protection
Response timeFastest mode (SHS)Operation and recovery: 100 μs each
High-speed mode (HS)Operation and recovery: 450 μs each
Standard mode (Stnd)Operation and recovery: 1 ms each
Giga Power Mode
(GIGA)
Operation and recovery: 16 ms each
Sensitivity AdjustmentSmart tuning (2-point tuning, full auto tuning, positioning tuning, maximum sensitivity tuning,
power tuning, percent tuning (-99% to +99%)) or manual adjustment
Maximum number of units that can be connected30 units30 units*3 when using model E3NW-ECT
16 units when using model E3NW-CCL
Mutual interference prevention units*49 units. Note: When the detection function is set to the fastest mode (SHS), the mutual interference prevention function is disabled.

* 1. 2 sensor outputs are assigned to the PLC through the network.
    By operating via the PLC network, various settings can be changed and detection values can be read.
* 2. Power consumption
When the power supply voltage is 10 V to 30 V
Normal mode: 1,080 mW or less (36 mA or less current consumption at 30 V power supply voltage / 75 mA or less current consumption at 10 V power supply voltage)
Eco function ON: 840 mW or less (28 mA or less current consumption at 30 V power supply voltage / 55 mA or less current consumption at 10 V power supply voltage)
Eco function LO: 960 mW or less (32 mA or less current consumption at 30 V power supply voltage / 65 mA or less current consumption at 10 V power supply voltage)
* 3. When connected to the Omron NJ series.
* 4. Tuning does not change the number of units.
This is the smallest number of mutual interference prevention units for the models E3NX and E3NC. Check the number of mutual interference prevention units and response speed for each model.

 
ItemsNPN outputModel E3NX-MA11Model E3NX-MA6Model E3NX-MAO
PNP outputModel E3NX-MA41Model E3NX-MA8
Connection methodPre-wiredConnector for simplified wiringConnection connector for sensor communication unit
TypeStandard typeFor sensor communication unit
functionAuto power
control (APC)
Available (always enabled)
Dynamic
power control
(DPC)
available
TimerSelectable from timer function disabled, off-delay, on-delay, one-shot, and on/off-delay. 1 ms to 9,999 ms
Zero resetNegative display possible (The threshold also shifts)
Reset settings*5Selectable from initial reset (factory default) and user reset (saved state)
Eco modeSelectable from OFF (digital display lit), ECO ON (digital display off), and ECO LO (digital display dimly lit)
Bank switching settingsSelectable from BANK1 to 4
Power tuning
at the time of shipment
Selectable from ON/OFF
Output 1 SettingsSelectable from normal detection mode and area detection mode
Output 2 settingsSelectable from normal detection mode, AND output mode, OR output mode, XOR output mode, GAP output mode,
rising edge synchronous mode, falling edge synchronous mode, and area detection mode
Hysteresis width settingSelectable from standard settings or user settings. In case of user settings, hysteresis width can be set from 0 to 9,999
Operating ambient illuminanceLight receiving surface illuminance, Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less
Ambient temperature range*6During operation:
When connecting 1 to 2 units: -25℃ to +55℃,
When connecting 3 to 10 units: -25℃ to +50℃,
When connecting 11 to 16 units: -25℃ to +45℃,
When connecting 17 to 30 units: -25℃ to +40℃
When storing: -30 to +70℃
(no freezing or condensation)
During operation:
When connecting 1 to 2 units: 0 to +55℃,
When connecting 3 to 10 units: 0℃ to +50℃,
When connecting 11 to 16 units: 0℃ to +45℃,
When connecting 17 to 30 units: 0℃ to +40℃
When storing: -30℃ to +70℃
(no freezing or condensation)
Ambient humidity rangeWhen operating/storing: 35 to 85% RH each in the above ambient temperature range (no condensation)
High2,000 m or less
Installation environmentPollution Level 3
Insulation resistance20 MΩ or more (500 V DC insulation resistance tester)
Withstand voltage1,000 V AC 50/60 Hz for 1 min
Vibration (endurance)10 to 55 Hz, 1.5 mm double amplitude, 2 hours in each direction of X, Y, and Z
Shock (endurance)500 m/s2 in each X, Y, Z direction 3 times150 m/s2 in each X, Y, Z direction 3 times
Protective structureIEC standard IP50
Weight (Packaging state / Main body only)approx. 115 g / approx. 75 gapprox. 60 g / approx. 20 gapprox. 65 g / approx. 25 g
MaterialCasePolycarbonate (PC)
coverPolycarbonate (PC)
CordPVC
AccessoryInstruction manual

* 5. BANK is not reset by user reset and is not saved by user save.
* 6. If the number of connected units is 11 or more, the ambient temperature range will be less than 50℃.

Part Number
E3NX-MA0
E3NX-MA6
E3NX-MA8
E3NX-MA11 2M
E3NX-MA41 2M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipProduct Type Output Format Connection Method Cord Length
(m)
Input/Output (Amplifier)

MYR 1,044.96

1 Piece(s) 9 Day(s) or more Sensor communication unit type-Connection connector for sensor communication unit--

MYR 1,032.28

1 Piece(s) 9 Day(s) or more Standard typeNPNReduced wiring connector type-2 output

MYR 1,032.28

1 Piece(s) 9 Day(s) or more Standard typePNPReduced wiring connector type-2 output

MYR 1,046.37

1 Piece(s) 9 Day(s) or more Standard typeNPNPre-wired type22 output