Compact flow sensor Rapiflow FSM3 series (stainless steel body type) (Part Numbers)

Compact flow sensor Rapiflow FSM3 series (stainless steel body type)

Click this image to zoom it.

Move the mouse over the image to zoom

  • LCD Display
  • Bar Display
  • IO-Link

[Features]
· Ideal for inert gas management where outgassing is undesirable
· IO-Link model now available
· LCD display with rotating indication
· Wide variety of variations
· Easy installation (option)
· Space-saving

(i)Caution

  • The product images are representative only. Specifications may vary by part number, including shape and color.

PDF

Part Number

Configured Part Number is shown.

Drawing

(LCD Display Type) (Flow Rate Range: 500 mL/min to 50 L/min)

· Connection port diameter: straight type Rc1/8, G1/8, NPT1/8

  • FSM3-L [B] [C] 2,3/AA1/AB1/AC1 (Full scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External shape figure 1
 

· Connection port diameter: Straight type G1/8

  • FSM3-L [B] [C] 2,3/AF1 (Full-scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External shape figure 2
 
· Connection port diameter: Straight type 1/4 inch double compression fitting
  • FSM3-L [B] [C] 2,3/AD1 (Full scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 3
· Connection port diameter: straight type 1/4 inch JXR male fitting
  • FSM3-L [B] [C] 2,3/AE1 (Full scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 4

With needle valve

· Connection port diameter: Rc1/8, G1/8, NPT1/8, 1/4 inch double compression fitting, 1/4 inch JXR male fitting

  • FSM3-L [B] [C] 2,3/AA1/AF1/AB1/AC1/AD/AE [G] [H] T (Full scale flow rate: 500 L/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 5

(LCD display type) (flow rate range: 50 L/min to 200 L/min)

· Connection port diameter: straight type Rc1/4, G1/4, NPT1/4

  • FSM3-L [B] [C] 2,3/BA1/BB1/BC1 (full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 6
 

· Connection port diameter: straight type G1/4 (BF1)

  • FSM3-L [B] [C] 2,3/BF1 (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 7
 
· Connection port diameter: Straight type 1/4 inch double compression fitting
  • FSM3-L [B] [C] 2,3/BD1 (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 8
· Connection port diameter: straight type 1/4 inch JXR male fitting
  • FSM3-L [B] [C] 2,3/BE1 (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 9

With needle valve

· Connection port diameter: Rc1/4, G1/4, NPT1/4, 1/4 inch double compression fitting, 1/4 inch JXR male fitting

  • FSM3-L [B] [C] 2,3/BA1/BF1/BB1/BC1/BD/BE [G] [H] T (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 10

*The shape of the top and underside of the main body is the same as the straight type.

(LCD Display Type) (Flow Rate Range: 500 L/min, 1,000 L/min)

· Connection port diameter: straight type Rc1/2, G1/2, NPT1/2

  • FSM3-L [B] [C] 2/CA1/CF1/CB1/CC1 (Full scale flow rate: 500, 1,000 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 11

(Bar Display Type) (Flow Rate Range: 500 mL/min to 50 L/min)

· Connection port diameter: straight type Rc1/8, G1/8, NPT1/8

  • FSM3-B [B] [C] 2,3/AA1/AB1/AC1 (Full scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 12
 

· Connection port diameter: Straight type G1/8

  • FSM3-B [B] [C] 2,3/AF1 (Full scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 12-2
 
· Connection port diameter: Straight type 1/4 inch double compression fitting
  • FSM3-B [B] [C] 2,3/AD1 (Full scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 12-3
· Connection port diameter: straight type 1/4 inch JXR male fitting
  • FSM3-B [B] [C] 2,3/AE1 (Full scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 12-4

(Bar Display Type) (Flow Rate Range: 50 L/min to 1,000 L/min)

· Connection port diameter: Straight type Rc1/4, G1/4, NPT1/4

  • FSM3-B [B] [C] 2,3/BA1/BB1/BC1 (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 22
 

· Connection port diameter: Straight type G1/4

  • FSM3-B [B] [C] 2,3/BF1 (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 23
 

· Connection port diameter: Straight type 1/4 inch double compression fitting

  • FSM3-B [B] [C] 2,3/BD1 (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 24

· Connection port diameter: Straight type 1/4 inch JXR male fitting

  • FSM3-B [B] [C] 2,3/BE1 (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 25

· Connection port diameter: Straight type Rc1/2, G1/2, NPT1/2

  • FSM3-B [B] [C] 2/CA1/CF1/CB1/CC1 (Full scale flow rate: 500, 1,000 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 26

(IO-Link) (Flow rate range: 500 mL/min to 50 L/min)

· Connection port diameter: straight type Rc1/8, G1/8, NPT1/8

  • FSM3-C [B] [C] 2,3/AA1/AB1/AC1 (Full scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 13
 

· Connection port diameter: Straight type G1/8

  • FSM3-C [B] [C] 2,3/AF1 (Full-scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 14
 
· Connection port diameter: Straight type 1/4 inch double compression fitting
  • FSM3-C [B] [C] 2,3/AD1 (Full-scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) external shape figure 15
· Connection port diameter: straight type 1/4 inch JXR male fitting
  • FSM3-C [B] [C] 2,3/AE1 (Full scale flow rate: 500 mL/min, 1, 2, 5, 10, 20, 50 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 16

(IO-Link) (Flow rate range: 50 L/min to 1,000 L/min)

· Connection port diameter: straight type Rc1/4, G1/4, NPT1/4

  • FSM3-C [B] [C] 2,3/BA1/BB1/BC1/ (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 17
 

· Connection port diameter: straight type G1/4

  • FSM3-C [B] [C] 2,3/BF1 (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 18
 
· Connection port diameter: Straight type 1/4 inch double compression fitting
  • FSM3-C [B] [C] 2,3/BD1 (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 19
· Connection port diameter: straight type 1/4 inch JXR male fitting
  • FSM3-C [B] [C] 2,3/BE1 (Full scale flow rate: 50, 100, 200 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 20

· Connection port diameter: straight type Rc1/2, G1/2, NPT1/2

  • FSM3-C [B] [C] 2/CA1/CF1/CB1/CC1 (Full scale flow rate: 500, 1,000 L/min)
Compact flow sensor Rapiflow FSM3 series (stainless steel body type) External Shape Figure 21

Product Specification

Product Specification

ItemsFSMS3- [ A ] [B] [C] [D] [E] [F] [G] [ H ] [I] - [ ]
[B]
005010020050100200500101201501102
Flow Direction[C]UOne-Way
BTwo-Way
Flow Rate
Range
(B/min)
*1
[B]U15 to 500 mL30 to 1,000 mL0.06 to 2.00 L0.15 to 5.00 L0.30 to 10.00 L0.6 to 20.0 L1.5 to 50.0 L3.0 to 100.0 L6 to 200 L15 to 500 L30 to 1,000 L
B-500 to
-15,
15 to
500 mL
-1,000 to
-30,
30 to
1,000 mL
-2.00 to
-0.06,
0.06 to
2.00 L
-5.00 to
-0.15,
0.15 to
5.00 L
-10.00 to
-0.30,
0.30 to
10.00 L
-20.0 to
-0.6,
0.6 to
20.0 L
-50.0 to
-1.5,
1.5 to
50.0 L
-100.0 to
-3.0,
3.0 to
100.0 L
-200 to
-6,
6 to
200L
-500 to
-15,
15 to
500L
-1,000 to
-30,
30 to
1,000 L
Type of Display4 digits + 4 digits    2-color LCD
Flow rate display range
(B/min) Note 2
[B]U-49 to
+549 mL
-99 to
+1,099 mL
-0.19 to
+2.19 L
-0.49 to
+5.49 L
-0.99 to
+10.99 L
-1.9 to
+2.19 L
-4.9 to
+54.9 L
-9.9 to
+109.9 L
-19 to
+219 L
-49 to
+549 L
-99 to
+1,099 L
B-549 to
+549 mL
-1,099 to
+1,099 mL
-2.19 to
+2.19 L
-5.49 to
+5.49 L
-10.99 to
+10.99 L
-2.19 to
+2.19 L
-54.9 to
+54.9 L
-10.9 to
+109.9 L
-219 to
+219 L
-549 to
+549 L
-1,099 to
+1,099 L
Totalized display  Note 3Indicated range0 to ± 9999999 mL0.00 to ±99999.99 L0.0 to ±999999.9 L0 to ±9999999 L
Pulse
output
rate
5 mL10 mL0.02 L0.05 L0.1 L0.2 L0.5 L1L2L5L10L
Usage conditionsCompatible fluid
Note 4
Clean air (JIS B 8392-1:2012 1.1.1 to 5.6.2), compressed air (JIS B 8392-1:2012 1.1.1 to 1.6.2), nitrogen gas
Argon, carbon dioxide gas, mixed gas (argon + carbon dioxide gas)-
Oxygen (When the oxygen specification is selected, the clean specification (wa) cannot be selected.
It will automatically be the degreasing process specification.)
-
temperature range0 to +50°C (no condensation)
Pressure range-0.09 to 1.00 MPa-0.09 to 0.75 MPa
Pressure resistance1.5 MPa
Operating ambient temperature, humidity0 to +50°C, 90% RH or less
Storage temperature-10 to +60℃
Accuracy  Note 5
(Fluid:
using dry air)
Accuracy  Note 6Within ±3% F.S. (outlet open air)   (Guaranteed range depends on "measurement flow rate range")
Repeatability
  Note 7
Within ±1% F.S. (outlet open air)
Temperature characteristicsWithin ±0.2% F.S./°C (15 to 35°C, 25°C reference)
Pressure characteristics±5% F.S. or less (based on open air at outlet)±5% F.S. or less
(based on 0.35 MPa)
Response time    Note 850 msec or less (when response time setting is OFF)
Switch
Output
[G]A, B, E, FNPN open collector output (50 mA or less, voltage drop 2.4 V or less)
C, D, G, HPNP open collector output (50 mA max, voltage drop 2.4 V max)
Analog
Output
Note 9
A, B, C, D1-5 V voltage output (load impedance 50 kΩ min)
E, F, G, H4-20 mA current output (load impedance 0 to 300 Ω)
Power supply voltage
Note 10
A, B, C, DDC 12 to 24 V (10.8 to 26.4 V), ripple rate 1% or less
E, F, G, H24 V DC (21.6 to 26.4 V), ripple rate 1% or less
Current consumption  Note 1145 mA or less
Lead⌀3.7 AWG26 equivalent x 5 cores (connector connection), insulator outer diameter ⌀1.0
Functions  Note 12(1) Gas type switching, (2) Setting copy function, (3) Flow rate accumulation, (4) Peak hold, others
Protective StructureEquivalent to IP40 (IEC standard)
Protective Circuit Note 13Reverse power supply connection protection, reverse switch output connection protection, switch output load short-circuit protection
Vibration resistance10 to 150 Hz, Max. 100 m/s2, XYZ directions, 2 hours each
EMC DirectiveEN55011, EN61000-6-2, EN61000-4-2/3/4/6/8
MountingMounting orientation Note 14Vertical / Horizontal Mounting
Direct introduction section Note 15N/A

Note 1: Converted to volumetric flow rate under standard conditions (20°C, 1 atm (101 kPa), 65% relative humidity). (For gases other than air: 20°C, 1 atm (101 kPa), 0% relative humidity)
Note 2: The display for each flow rate is as follows.

Compact flow sensor Rapiflow FSM3 series (stainless steel body type) Product Specification

Note 3: The accumulated flow rate is a calculated (reference) value. When using the accumulation storage function, please ensure that the number of saves does not exceed the memory device's access limit (maximum of 1,000,000 times). (Changes to various settings are also counted as accesses.)
Number of saves = operating time / 5 minutes < 1,000,000 times
When the instantaneous flow rate is 1% or less, it is not counted as accumulated flow rate.
Note 4: Use dry gas that does not contain corrosive components such as chlorine, sulfur, or acids, and clean gas that does not contain dust or oil mist. When using compressed air, please use clean air of class 1.1.1 to 1.6.2 as specified in JIS B 8392-1:2012. Compressed air from compressors contains condensate (water, oxidized oil, contaminants, etc.). To maintain the functionality of this product, please install a filter, air dryer (min. pressure dew point 10°C or lower), and oil mist filter (maximum oil concentration 0.1 mg/m3) on the inlet (upstream) side of this product before use.
A dedicated model is available for oxygen gas. To prevent fire accidents, do not use oxygen again if any fluid other than oxygen has been used even once.
Note 5: Compressed air is used for adjustment and inspection of this product. For gases other than air, the accuracy is provided as a reference.
Note 6: The accuracy is based on CKD's standard flow meter and does not indicate absolute accuracy.
Please note that repeatability, temperature characteristics, and pressure characteristics are not included in the ±3% F.S. accuracy.
Please consider separately depending on the operating environment and usage conditions.
Note 7: This refers to repeatability over a short period. Changes over time are not included. (For details, please refer to the product specification sheet.)
Note 8: The actual response time varies depending on the piping conditions. The response time setting can be selected from approx. 50 msec to 1.5 sec as a reference.
Note 9: The output impedance of the analog output voltage output type is approx. 1 kΩ. If the impedance of the connected load is low, the output value and error will increase. Please check the error due to the impedance of the connected load before use.
Note 10: Please note that the power supply voltage specifications are different for voltage output type and current output type.
Note 11: This is the current when connected to 24 V DC with no load connected. Please note that the current consumption will change depending on the connection status of the load.
Note 12: With the gas type switching function, you can switch to argon, carbon dioxide, or argon 80% + carbon dioxide 20%. After switching, the full scale flow rate and analog output will be as shown below. (Please note that the gas type switching function cannot be set for the oxygen type, 500 L/min model, or 1,000 L/min model.)

Gas TypeFlow DirectionFull scale flow rateAnalog output
VoltageCurrent
· Air
· Nitrogen
· Argon
· Argon 80% + Carbon dioxide 20%
One-Way0 to 100%1 to 5 V4 to 20 mA
Two-Way-100 to +100%
· Carbon dioxideOne-Way0 to 50%1 to 3 V4 to 20 mA
Two-Way-50 to +50%2 to 4 V8 to 16 mA

The presence or absence of the "setting copy function" is selected in "(T) output specifications".
Please note that models with the "setting copy function" do not have the "external input" function.

Note 13: The protection circuit of this product is effective only against certain incorrect connections and load short-circuits, and does not protect against all types of incorrect connections.
Note 14: This product measures changes in heat distribution caused by flow.
When installed vertically, the heat distribution may change due to convection, which can cause the zero point to shift.
Note 15: Depending on the piping conditions, it may affect the accuracy. For more accurate measurement, provide a straight pipe section that is 10 times the inner diameter of the piping.
For the 500 L/min and 1,000 L/min models, use piping with an inner diameter of 9 mm or more. If the inner diameter is 9 mm or less, accuracy may diminish.
Note 16: For mass, please refer separately.

Product Specification

ItemsFSMS3- [ A ] [B] [C] [D] [E] [F] [G] [ H ] [I] - [ ]
[B]
005010020050100200500101201501102
Flow Direction[C]UOne-Way
BTwo-Way
Flow rate measurement range
(B/min) Note 1
[B]U15 to 500 mL30 to 1,000 mL0.06 to 2.00 L0.15 to 5.00 L0.30 to 10.00 L0.6 to 20.0 L1.5 to 50.0 L3.0 to 100.0 L6 to 200 L15 to 500 L30 to 1,000 L
B-500 to
-15,
15 to
500 mL
-1,000 to
-30,
30 to
1,000 mL
-2.00 to
-0.06,
0.06 to
2.00 L
-5.00 to
-0.15,
0.15 to
5.00 L
-10.00 to
-0.30,
0.30 to
10.00 L
-20.0 to
-0.6,
0.6 to
20.0 L
-50.0 to
-1.5,
1.5 to
50.0 L
-100.0 to
-3.0,
3.0 to
100.0 L
-200 to
-6,
6 to
200L
-500 to
-15,
15 to
500L
-1,000 to
-30,
30 to
1,000 L
Type of DisplayLED bar indication
Usage conditionsCompatible fluid
*2
Clean air (JIS B 8392-1:2012 1.1.1 to 5.6.2), compressed air (JIS B 8392-1:2012 1.1.1 to 1.6.2), nitrogen gas
Oxygen (When the oxygen specification is selected, the clean specification (wa) cannot be selected.
It will automatically be the degreasing process specification.)
-
temperature range0 to +50°C (no condensation)
Pressure range-0.09 to +1.00 MPa-0.09 to +0.75 MPa
Pressure resistance1.5 MPa
Operating ambient temperature, humidity0 to +50°C, 90% RH or less
Storage temperature-10 to +60℃
AccuracyAccuracy  *3Within ±3% F.S. (outlet open air)   (Guaranteed range depends on "measurement flow rate range")
Repeatability
  *4
Within ±1% F.S. (outlet open air)
Temperature characteristicsWithin ±0.2% F.S./°C (15 to 35°C, 25°C reference)
Pressure characteristics±5% F.S. or less (based on open air at outlet)±5% F.S. or less
(based on 0.35 MPa)
Response time    *550 ms or less
Analog output
*6
[G]J1-5 V voltage output (connection load impedance = 50 kΩ or more)
K4-20 mA current output (load impedance 0 to 300 Ω)
Power supply voltage
*7
JDC 12 to 24 V (10.8 to 26.4 V), ripple rate 1% or less
K24 V DC (21.6 to 26.4 V), ripple rate 1% or less
Current consumption  *845 mA or less
Lead⌀3.7 AWG26 equivalent x 4 cores (connector connection), insulator outer diameter ⌀1.0
Protective StructureEquivalent to IP40 (IEC standard)
Protection circuit  Note 9Power supply reverse connection protection
Vibration resistance10 to 150 Hz, Max. 100 m/s2, XYZ directions, 2 hours each
EMC DirectiveEN55011, EN61000-6-2, EN61000-4-2/3/4/6/8
MountingMounting orientation  Note 10Vertical / Horizontal Mounting
Direct introduction section  Note 11N/A

Note 1: Converted to volumetric flow rate under standard conditions (20°C, 1 atm (101 kPa), 65% relative humidity)
(For gases other than air: 20°C, 1 atm (101 kPa), 0% relative humidity)
note2: Please use clean, dry gas that does not contain corrosive components such as chlorine, sulfur, or acids, and that is free of dust and oil mist. When using compressed air, please use clean air conforming to JIS B 8392-1: 2012 class 1.1.1 to 1.6.2. Compressed air from compressors contains condensate (water, oxidized oil, contaminants, etc.). To maintain the functionality of this product, please install a filter, air dryer (min. pressure dew point 10°C or lower), and oil mist filter (maximum oil concentration 0.1 mg/m3) on the inlet (upstream) side of this product before use. (Please refer to the recommended circuit.)
A dedicated model is available for oxygen gas. To prevent fire accidents, do not use oxygen again if any fluid other than oxygen has been used even once.
Note 3: Accuracy is based on CKD's standard flow meter and does not indicate absolute accuracy. Please note that repeatability, temperature characteristics, and pressure characteristics are not included in the ±3% F.S. accuracy.
Please consider separately depending on the operating environment and usage conditions.
Note 4: This refers to repeatability over a short period. Changes over time are not included. (For details, please refer to the product specification sheet.)
Note 5: The actual response time varies depending on the piping conditions.
Note 6: The output impedance of the analog output voltage output type is approx. 1 kΩ. If the impedance of the connected load is low, the output value and error will increase. Please check the error due to the impedance of the connected load before use.
Note 7: Please note that the power supply voltage specifications of the voltage output type and current output type are different.
Note 8: This is the current when connected to 24 V DC with no load connected. Please note that the current consumption will change depending on the connection status of the load.
Note 9: The protection circuit of this product is effective only against certain incorrect connections and load short-circuits, and does not protect against all types of incorrect connections.
Note 10: This product measures changes in heat distribution caused by flow.
When installed vertically, the heat distribution may change due to convection, which can cause the zero point to shift.
Note 11: Under certain piping conditions, accuracy may be affected. For more accurate measurement, provide a straight pipe section that is 10 times the inner diameter of the piping.
For the 500 L/min and 1,000 L/min models, please use piping with an inner diameter of 9 mm or more. If the inner diameter is 9 mm or less, accuracy may diminish.
Note 12: For mass, please refer to a separate table.

Product Specification

ItemsFSMS3- [ A ] [B] [C] [D] [E] [F] [G] [ H ] [I] - [ ]
[B]
005010020050100200500101201501102
Flow Direction[C]UOne-Way
BTwo-Way
Flow rate measurement range
(B/min) Note 1
[B]U15 to 500 mL30 to 1,000 mL0.06 to 2.00 L0.15 to 5.00 L0.30 to 10.00 L0.6 to 20.0 L1.5 to 50.0 L3.0 to 100.0 L6 to 200 L15 to 500 L30 to 1,000 L
B-500 to
-15,
15 to
500 mL
-1,000 to
-30,
30 to
1,000 mL
-2.00 to
-0.06,
0.06 to
2.00 L
-5.00 to
-0.15,
0.15 to
5.00 L
-10.00 to
-0.30,
0.30 to
10.00 L
-20.0 to
-0.6,
0.6 to
20.0 L
-50.0 to
-1.5,
1.5 to
50.0 L
-100.0 to
-3.0,
3.0 to
100.0 L
-200 to
-6,
6 to
200L
-500 to
-15,
15 to
500L
-1,000 to
-30,
30 to
1,000 L
Type of DisplayLED display (power lamp, status lamp)
Usage conditionsCompatible fluid
*2
Clean air (JIS B 8392-1:2012 1.1.1 to 5.6.2), compressed air (JIS B 8392-1:2012 1.1.1 to 1.6.2), nitrogen gas
Argon, carbon dioxide gas, mixed gas (argon + carbon dioxide gas)-
Oxygen (When the oxygen specification is selected, the clean specification (wa) cannot be selected.
It will automatically be the degreasing process specification.)
-
temperature range0 to 50°C (no condensation)
Pressure range-0.09 to +1.00 MPa-0.09 to +0.75 MPa
Pressure resistance1.5 MPa
Operating ambient temperature, humidity0 to 50°C, 90% RH or less
Storage temperature-10 to +60℃
Accuracy  *3Accuracy  Note 4Within ±3% F.S. (outlet open air)   (Guaranteed range depends on "measurement flow rate range")
Repeatability
  Note 5
Within ±1% F.S. (outlet open air)
Temperature characteristicsWithin ±0.2% F.S./°C (15 to 35°C, 25°C reference)
Pressure characteristics±5% F.S. or less (based on open air at outlet)±5% F.S. or less
(based on 0.35 MPa)
Response time    Note 650 ms or less
Power supply voltageDC18 to 30 V Ripple rate 1% or less
Current consumption  Note 745 mA or less
Lead  Note 8M12 both sides connector lead (3 m)   Equivalent to AWG #23, 4-core
Functions  Note 9  Note 10(1) Gas type switching, (2) Flow rate totalization, (3) Peak hold, others
Protective StructureEquivalent to IP40 (IEC standard)
Protection circuit  Note 11Power supply reverse connection protection
Vibration resistance  Note 1210 to 150 Hz, Max. 100 m/s2, XYZ directions, 2 hours each
EMC DirectiveEN55011, EN61000-6-2, EN61000-4-2/3/4/6/8
MountingMounting orientation  Note 13Vertical / Horizontal Mounting
Direct introduction section  Note 14N/A

Note 1: Converted to volumetric flow rate under standard conditions (20°C, 1 atm (101 kPa), 65%). (For gases other than air, use 20°C, 1 atm (101 kPa), 0% RH)
Note 2: Please use a dry gas that does not contain corrosive components such as chlorine, sulfur, or acids, and a clean gas that does not contain dust or oil mist. When using compressed air, please use clean air of class 1.1.1 to 1.6.2 as specified in JIS B 8392-1:2012. Compressed air from compressors contains condensate (water, oxidized oil, contaminants, etc.). To maintain the function of this product, please install a filter, air dryer (min. pressure dew point 10°C or lower), and oil mist filter (maximum oil concentration 0.1 mg/m3) on the inlet (upstream) side of this product. (Please refer to the recommended circuit.)
A dedicated model is available for oxygen gas. To prevent fire accidents, do not use oxygen again if any fluid other than oxygen has been used even once.
Note 3: Compressed air is used for the adjustment and inspection of this product. For gases other than air, the accuracy is for reference only.
Note 4: The accuracy is based on CKD's standard flow meter and does not indicate absolute accuracy. Please note that repeatability, temperature characteristics, and pressure characteristics are not included in the ±3% F.S. accuracy.
Please consider separately depending on the operating environment and usage conditions.
Note 5: This refers to repeatability over a short period of time. Changes over time are not included. (For details, please refer to the product specification sheet.)
Note 6: The actual response time will vary depending on the piping conditions.
Note 7: This is the current when connected to 24 V DC with no load connected. Please note that the current consumption will change depending on the connection status of the load.
Note 8: The male side is straight, and the female side is angle. Tighten the M12 connector to a torque of 0.5 N⋅m or less.
Please note that tightening with excessive force may result in damage.
Note 9: The gas type switching function allows you to switch between argon, carbon dioxide, and argon 80% + carbon dioxide 20%. The measurement flow rate range after switching is as shown below. (For the oxygen type, 500 L/min model, and 1,000 L/min model, the gas type cannot be switched.)

Compact flow sensor Rapiflow FSM3 series (stainless steel body type) Product Specification 2

Note 10: The accumulated flow rate is a calculated (reference) value. When using the accumulation storage function, please ensure that the number of saves does not exceed the memory device's access limit (maximum of 1,000,000 times). (Changes to various settings are also counted as accesses.)
Number of saves = operating time / 5 minutes < 1,000,000 times
When the instantaneous flow rate is 1% or less, it is not counted as accumulated flow rate.
Note 11: The protection circuit of this product is effective only against certain incorrect connections and load short-circuit, and does not protect against all types of incorrect connections.
Note 12: Depending on vibration conditions, communication errors may occur. Please install in a location with as little vibration as possible.
Note 13: This product measures changes in heat distribution caused by flow.
When installed vertically, the heat distribution may change due to convection, which can cause the zero point to shift.
Note 14: Piping conditions may affect accuracy. For more accurate measurement, provide a straight pipe section that is 10 times the inner diameter of the piping.
For the 500 L/min and 1,000 L/min models, please use piping with an inner diameter of 9 mm or more. If the inner diameter is 9 mm or less, accuracy may diminish.
Note 15: Please refer to a separate document for mass.

Specifications Table

Part numberConnection port diameter(A) dimension
FSM3-B**2CA1Rc1/280
FSM3-B**2CF1G1/280
FSM3-B**2CB1G1/295.4
FSM3-B**2CC1NPT 1/280
FSM3-L**2CA1Rc1/280
FSM3-L**2CF1G1/280
FSM3-L**2CB1G1/295.4
FSM3-L**2CC1NPT 1/280
FSM3-C**2CA1Rc1/280
FSM3-C**2CF1G1/280
FSM3-C**2CB1G1/295.4
FSM3-C**2CC1NPT 1/280
Part Number
Part NumberMinimum order quantityVolume DiscountDays to ShipFluid Type Flow Rate Range (Max. Value)
(L/min)
Output Method Analog Output Specification Pipe Port Type Plumbing Thread Type Plumbing Thread Nominal Number of Output Points Analog Voltage Output
(V)
Analog Current Output
(mA)
Flow Direction Display Connection port size (details) Output specifications Switch output Copy function Unit specifications Optional valve Lead Mounting attachment Clean Specifications

Loading...

  1. 1
 

Basic Information

Type Flow rate sensor Sensor, Monitor Structure Integrated shape Pressure Resistant(MPa) 1.5
Body Material Stainless Steel Piping direction Straight Accompanying documents Not Included

Additional Products in this Category