SMC Solenoid Valve.
[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Piping variations
· Clearance
· Improved armature durability
· Low noise construction
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Tube Dia. | Orifice Dia. (Ø) | Operating Pressure Differential Range (MPa) | Insulation Class | Pipe opening type (details) | Voltage | Sealing materials | Lead wire exit direction | Option | Body material | Bracket | Detailed type | Functions | Lead wire electrical entry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,385.20 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 110 V AC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,290.56 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 12 V DC | NBR | Standard | None | SUS | None | Water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,377.32 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. | SUS | Included | Water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,377.32 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. | SUS | None | Water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,259.05 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | EPDM | Standard | None | SUS | None | Water | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 1,270.55 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | EPDM | Standard | None | SUS | Included | Water | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 574.29 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | FKM | Standard | None | C37 | None | Oil | None | Grommet | ||
MYR 571.27 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 110 V AC | FKM | Standard | None | C37 | None | Oil | None | Grommet (With surge voltage suppressor) | ||
MYR 600.37 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 230 V DC | FKM | Standard | None | C37 | None | Oil | None | Grommet (With surge voltage suppressor) | ||
MYR 623.39 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 110 V AC | FKM | Standard | None | C37 | None | Oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 662.23 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | FKM | Standard | None | C37 | None | Oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 699.27 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | FKM | Standard | None | C37 | Included | Oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 662.23 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 110 V AC | FKM | Standard | None | C37 | None | Oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 670.11 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 110 V AC | FKM | Standard | None | C37 | Included | Oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 687.08 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 200 V AC | FKM | Standard | None | C37 | None | Oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 657.92 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 220 V AC | FKM | Standard | None | C37 | None | Oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,302.06 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 24 V DC | FKM | Standard | None | SUS | Included | Oil | None | Grommet | ||
MYR 1,270.50 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 110 V AC | FKM | Standard | None | SUS | None | Oil | None | Grommet (With surge voltage suppressor) | ||
MYR 1,319.65 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | B | None | 110 V AC | FKM | Standard | None | SUS | None | Oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 553.06 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 24 V DC | EPDM | Standard | None | C37 | None | High temperature water | None | Grommet | ||
MYR 565.29 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 24 V DC | EPDM | 90° | None | C37 | None | High temperature water | None | Grommet | ||
MYR 553.06 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | H | None | 110 V AC | EPDM | Standard | None | C37 | None | High temperature water | None | Grommet (With surge voltage suppressor) | ||
MYR 628.65 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | H | None | 110 V AC | EPDM | Standard | None | C37 | None | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 646.53 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | H | None | 230 V DC | EPDM | Standard | Oil-free | C37 | Included | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 710.76 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 24 V DC | EPDM | Standard | None | C37 | Included | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 672.88 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | H | None | 110 V AC | EPDM | Standard | None | C37 | None | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 681.61 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | H | None | 110 V AC | EPDM | 270° | None | C37 | None | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 672.88 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | H | None | 220 V AC | EPDM | Standard | None | C37 | None | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,213.53 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 24 V DC | EPDM | Standard | None | SUS | None | High temperature water | None | Grommet | ||
MYR 1,317.04 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 24 V DC | EPDM | Standard | None | SUS | None | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,349.37 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 24 V DC | EPDM | 270° | None | SUS | None | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,324.80 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 24 V DC | EPDM | Standard | Oil-free | SUS | None | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,575.93 | 1 Piece(s) | 43 Day(s) | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | H | None | 110 V AC | EPDM | Standard | None | SUS | None | High temperature water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,298.49 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | H | None | 100 V AC | EPDM | Standard | Oil-free | SUS | None | High temperature water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,360.76 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 24 V DC | EPDM | Standard | None | SUS | None | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,388.76 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~1 | H | None | 110 V AC | EPDM | Standard | Oil-free | SUS | None | High temperature water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 718.64 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 110 V AC | FKM | Standard | None | C37 | None | High temperature oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 647.64 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 230 V DC | FKM | 90° | None | C37 | None | High temperature oil | None | Conduit (With surge voltage suppressor) | ||
MYR 1,386.64 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 24 V DC | FKM | Standard | None | SUS | None | High temperature oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,430.86 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 15 | 0~0.7 | H | None | 24 V DC | FKM | Standard | None | SUS | None | High temperature oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 647.64 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | Grommet | ||
MYR 613.08 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | Grommet | ||
MYR 639.81 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 605.32 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 683.56 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Air | None | Grommet (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 669.99 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 691.39 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | 180° | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 773.84 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 626.27 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | None | Conduit (With surge voltage suppressor) | ||
MYR 631.93 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 675.63 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 12 V DC | NBR | Standard | None | C37 | None | Air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 683.24 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 683.24 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 100 V AC | NBR | Standard | None | C37 | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 683.24 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Air | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 663.45 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 12 V DC | NBR | Standard | None | C37 | None | Air | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 1,541.00 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | SUS | None | Air | None | Grommet | ||
MYR 1,616.87 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | SUS | Included | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,609.12 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 200 V AC | NBR | Standard | Oil-free | SUS | None | Air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 1,616.87 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 100 V AC | NBR | Standard | Oil-free | SUS | None | Air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 1,672.62 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | SUS | Included | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 1,647.90 | 1 Piece(s) | 23 Day(s) or more | Air | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | Oil-free | SUS | None | Air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 647.64 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Water | None | Grommet | ||
MYR 605.32 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 675.63 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 683.56 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | Oil-free | C37 | None | Water | None | Grommet (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 691.39 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | 90° | None | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 654.47 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 669.99 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | Water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 702.89 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 626.27 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Water | None | Conduit (With surge voltage suppressor) | ||
MYR 626.27 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Water | None | Conduit (With surge voltage suppressor) | ||
MYR 655.57 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Water | None | Faston | ||
MYR 638.90 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 220 V AC | NBR | Standard | None | C37 | None | Water | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 708.78 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | Water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 746.59 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | 180° | None | C37 | Included | Water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 693.32 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 110 V AC | NBR | Standard | None | C37 | None | Water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 683.24 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 707.20 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 100 V AC | NBR | Standard | None | C37 | None | Water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 663.45 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | C37 | None | Water | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 1,552.21 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | SUS | None | Water | None | Grommet | ||
MYR 1,664.69 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. | SUS | None | Water | None | Grommet | ||
MYR 1,655.72 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | Compatible with low concentration ozone, deionized water, etc. / Oil-free | SUS | None | Water | None | Grommet | ||
MYR 1,613.81 | 1 Piece(s) | 23 Day(s) or more | Water | 3/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | 20 | 0~1 | B | None | 24 V DC | NBR | Standard | None | SUS | None | Water | None | Grommet (With surge voltage suppressor) |
Loading...
| Type | Electromagnetic Type | Driving Type | Pilot Kick Type | Operating Temperature Range(°C) | -20::60 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy