SMC Solenoid Valve.
[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Low noise construction
· Piping variations
· Clearance
· Improved armature durability
Part Number
Configured Part Number is shown.
| Valve Specifications | Valve Structure | Pilot operated 2 port diaphragm type | |
|---|---|---|---|
| Withstand Pressure | 2.0 MPa (resin body type: 1.5 MPa) | ||
| Body Material | Aluminum, resin, C37, SUS, CAC408 | ||
| Seal Materials | NBR, FKM, EPDM*3 | ||
| Enclosure | Dustproof, jetproof (IP65)*1, *4 | ||
| Environment | Locations without corrosive or explosive gases | ||
| Coil Specifications | Rated Voltage | AC | 100 V AC, 200 V AC, 110 V AC, 230 V AC, (220 V AC, 240 V AC, 48 V AC, 24 V AC)*2 |
| DC | 24 V DC, (12 V DC)*2 | ||
| Allowable Voltage Fluctuation | ±10% of rated voltage | ||
| Allowable Leakage Voltage | AC | 5% or less of rated voltage | |
| DC | 2% or less of rated voltage | ||
| Coil Insulation Type | Class B, class H | ||
*1: Electrical entry "Faston" type terminal is IP40 compliant
*2 Voltage inside () indicates special voltage. (See the SMC catalog)
*3: See the catalog regarding seal material EPDM.
*4: See the SMC catalog glossary for information on protection grades. Contact the SMC support center regarding use in locations that require water resistance.

VXD23 diagram

VXD24 diagram

VXD25/26 diagram

VXD27/28/29 diagram
| Number | Part Name | Model | Material |
|---|---|---|---|
| 1 | Body | VXD23 | C37, SUS, Aluminum, resin (PBT) |
| VXD24 to 26 | C37, SUS | ||
| VXD27 to 29 | CAC408 | ||
| 2 | Bonnet | VXD23/24 | SUS |
| VXD25, 26 | C37, SUS | ||
| VXD27 to 29 | CAC408 | ||
| 3 | Diaphragm Assembly | VXD23 to 29 | SUS, NBR, FKM, EPDM |
| 4 | Spring | VXD23 to 29 | SUS |
| 5 | O-Ring | VXD23 to 26 | NBR, FKM, EPDM |
| 6 | Buffer | VXD23/24 | PPS |
| 7 | Stopper | VXD23 to 29 | NBR, FKM, EPDM |
| 8 | Armature Core | Fe | |
| 9 | Tube | SUS | |
| 10 | Spring | SUS | |
| 11 | Armature Assembly | SUS, NBR, FKM, EPDM, resin (PPS) | |
| 12 | Solenoid Coil | Cu + Fe + resin |
Operation

VXD2A diagram

VXD2B diagram

VXD2C/2D diagram

VXD2E, 2F, 2G diagram
| Number | Part Name | Model | Material |
|---|---|---|---|
| 1 | Body | VXD2A | C37, SUS, Aluminum, resin (PBT) |
| VXD2B to 2D | C37, SUS | ||
| VXD2E to 2G | CAC408 | ||
| 2 | Bonnet | VXD2A, 2B | SUS |
| VXD2C, 2D | C37, SUS | ||
| VXD2E to 2G | CAC408 | ||
| 3 | Diaphragm Assembly | VXD2A to 2G | SUS, NBR, FKM, EPDM |
| 4 | Spring | VXD2A to 2G | SUS |
| 5 | O-Ring | VXD2A to 2D | NBR, FKM, EPDM |
| 6 | Buffer | VXD2A, 2B | PPS |
| 7 | Sleeve Assembly | VXD2A to 2G | SUS, resin (PPS) |
| 8 | Push Rod Assembly | Resin (PPS), SUS, NBR, FKM, EPDM | |
| 9 | Spring | SUS | |
| 10 | O-Ring A | NBR, FKM, EPDM | |
| 11 | O-Ring B | NBR, FKM, EPDM | |
| 12 | Adapter | Resin (PPS) | |
| 13 | O-Ring C | NBR, FKM, EPDM | |
| 14 | Solenoid Coil | Cu + Fe + resin |
Operation
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Applicable Fluid | Plumbing Thread Nominal | Operating Environment | Switching Type | Connection Type | Tube Dia. | Tube Flange Nominal | Orifice Dia. (Ø) | Operating Pressure Differential Range (MPa) | Insulation Class | Pipe opening type (details) | Voltage | Sealing materials | Lead wire exit direction | Option | Body material | Bracket | Detailed type | Functions | Lead wire electrical entry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 379.84 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. | C37 | None | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 323.56 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | C37 | None | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 328.54 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 341.73 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 328.54 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 341.73 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 444.69 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. | C37 | None | For water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 300.34 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | C37 | None | For water | None | Conduit (With surge voltage suppressor) | ||
MYR 331.60 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 200 V AC | NBR | None | None | C37 | None | For water | None | Conduit (With surge voltage suppressor) | ||
MYR 279.39 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 12 V DC | NBR | None | None | C37 | None | For water | Special voltage | Grommet | ||
MYR 292.58 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 12 V DC | NBR | Standard | None | C37 | Included | For water | Special voltage | Grommet | ||
MYR 331.60 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 220 V AC | NBR | None | None | C37 | None | For water | Special voltage | Conduit (With surge voltage suppressor) | ||
MYR 367.33 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | C37 | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 380.58 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 413.13 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | None | C37 | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 367.33 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | C37 | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 380.58 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 344.56 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | C37 | None | For water | Without DIN connector | DIN terminal (With surge voltage suppressor) | ||
MYR 379.84 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. | C37 | None | For water | None | Grommet | ||
MYR 279.39 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | None | C37 | None | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 279.39 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | C37 | None | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 328.54 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 388.73 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | 90° | None | C37 | Included | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 328.54 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 100 V AC | NBR | None | None | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 328.54 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 341.73 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 373.74 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 230 V DC | NBR | None | None | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 300.34 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | C37 | None | For water | None | Conduit (With surge voltage suppressor) | ||
MYR 279.39 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 12 V DC | NBR | None | None | C37 | None | For water | Special voltage | Grommet | ||
MYR 292.58 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 12 V DC | NBR | Standard | None | C37 | Included | For water | Special voltage | Grommet | ||
MYR 362.23 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 24 V DC | NBR | None | None | C37 | None | For water | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 367.33 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | C37 | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 380.58 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 380.58 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 369.93 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | For water | With light | Conduit terminal (With surge voltage suppressor) | ||
MYR 315.91 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | C37 | None | For water | None | Grommet | ||
MYR 349.26 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | C37 | None | For water | None | Grommet (With surge voltage suppressor) | ||
MYR 364.95 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 424.07 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 364.95 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | C37 | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 370.55 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | C37 | None | For water | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 336.30 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | C37 | None | For water | None | Conduit (With surge voltage suppressor) | ||
MYR 364.95 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 220 V AC | NBR | None | None | C37 | None | For water | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 370.12 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 12 V DC | NBR | None | None | C37 | None | For water | Special voltage | Faston | ||
MYR 403.79 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | C37 | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 403.79 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | C37 | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 433.18 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 464.75 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | Standard | None | SUS | Included | For water | None | Grommet | ||
MYR 455.27 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | NBR | None | None | SUS | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 562.96 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. | SUS | None | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 512.07 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | Standard | None | SUS | Included | For water | None | DIN terminal (With surge voltage suppressor) | ||
MYR 484.08 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 12 V DC | NBR | 270° | None | SUS | None | For water | Special voltage | Conduit (With surge voltage suppressor) | ||
MYR 598.78 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | SUS | None | For water | None | Conduit (With surge voltage suppressor) | ||
MYR 620.84 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 110 V AC | NBR | None | None | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 665.42 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | B | None | 230 V DC | NBR | None | None | SUS | None | For water | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 356.34 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | C37 | None | For oil | None | Grommet | ||
MYR 393.20 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 344.00 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.4 | B | None | 12 V DC | FKM | None | None | C37 | None | For oil | Special voltage | Grommet | ||
MYR 445.24 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 110 V AC | FKM | Standard | None | C37 | Included | For oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 445.24 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 110 V AC | FKM | Standard | None | C37 | Included | For oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 472.68 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 110 V AC | FKM | None | None | C37 | None | For oil | None | DIN terminal (With surge voltage suppressor) | ||
MYR 465.91 | 1 Piece(s) | 23 Day(s) or more | Oil | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | B | None | 110 V AC | FKM | None | None | C37 | None | For oil | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 515.64 | 1 Piece(s) | 23 Day(s) or more | Oil | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.4 | B | None | 24 V DC | FKM | None | None | SUS | None | For oil | None | Grommet | ||
MYR 353.40 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | H | None | 230 V DC | EPDM | None | None | C37 | None | For high temperature water (99°C) | None | Grommet (With surge voltage suppressor) | ||
MYR 433.67 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | H | None | 230 V DC | EPDM | Standard | None | C37 | Included | For high temperature water (99°C) | None | DIN terminal (With surge voltage suppressor) | ||
MYR 385.92 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | H | None | 24 V DC | EPDM | None | None | C37 | None | For high temperature water (99°C) | Special voltage | Conduit (With surge voltage suppressor) | ||
MYR 456.88 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | H | None | 100 V AC | EPDM | None | None | C37 | None | For high temperature water (99°C) | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 421.05 | 1 Piece(s) | 23 Day(s) or more | Water | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | H | None | 24 V DC | EPDM | None | None | C37 | None | For high temperature water (99°C) | Special voltage | Conduit (With surge voltage suppressor) | ||
MYR 480.56 | 1 Piece(s) | 23 Day(s) or more | Water | 1/4 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.7 | H | None | 200 V AC | EPDM | None | None | SUS | None | For high temperature water (99°C) | None | Grommet (With surge voltage suppressor) | ||
MYR 602.35 | 1 Piece(s) | 23 Day(s) or more | Water | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 10 | 0.02~0.5 | H | None | 24 V DC | EPDM | 90° | Oil-free | SUS | None | For high temperature water (99°C) | None | DIN terminal (With surge voltage suppressor) | ||
MYR 478.48 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 24 V DC | NBR | None | None | C37 | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 547.20 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 110 V AC | NBR | Standard | None | C37 | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 429.45 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 220 V AC | NBR | None | None | C37 | None | For air | Special voltage | Grommet (With surge voltage suppressor) | ||
MYR 501.33 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 220 V AC | NBR | None | None | C37 | None | For air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 599.16 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 220 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | Special voltage | DIN terminal (With surge voltage suppressor) | ||
MYR 531.39 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 240 V AC | NBR | None | None | C37 | None | For air | Special voltage | Conduit terminal (With surge voltage suppressor) | ||
MYR 517.33 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 24 V DC | NBR | None | None | C37 | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 701.29 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 24 V DC | FKM | Standard | Compatible with low concentration ozone, deionized water, etc. | C37 | Included | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 663.34 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 562.96 | 1 Piece(s) | 23 Day(s) or more | Air | 3/8 | Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 220 V AC | NBR | None | None | C37 | None | For air | With light | DIN terminal (With surge voltage suppressor) | ||
MYR 429.45 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 24 V DC | NBR | None | None | C37 | None | For air | None | Grommet | ||
MYR 590.95 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 24 V DC | FKM | None | Compatible with low concentration ozone, deionized water, etc. | C37 | None | For air | None | Grommet | ||
MYR 499.88 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 200 V AC | NBR | Standard | None | C37 | Included | For air | None | Grommet (With surge voltage suppressor) | ||
MYR 673.98 | 1 Piece(s) | 3 Day(s) | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 24 V DC | NBR | None | None | C37 | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 504.53 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 24 V DC | NBR | Standard | None | C37 | Included | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 478.48 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 110 V AC | NBR | None | None | C37 | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 476.63 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 230 V DC | NBR | None | None | C37 | None | For air | None | DIN terminal (With surge voltage suppressor) | ||
MYR 531.39 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 24 V DC | NBR | None | None | C37 | None | For air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 653.97 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / No oil / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 100 V AC | FKM | None | Compatible with low concentration ozone, deionized water, etc. / Oil-free | C37 | None | For air | None | Conduit terminal (With surge voltage suppressor) | ||
MYR 486.35 | 1 Piece(s) | 23 Day(s) or more | Air | 1/2 | Standard / Dust Resistant / Jet Proof Type | Normally Closed | NPT | - | - | 15 | 0.02~1 | B | None | 230 V DC | NBR | None | None | C37 | None | For air | None | Conduit terminal (With surge voltage suppressor) |
Loading...
| Type | Electromagnetic Type | Driving Type | Pilot Type | Operating Temperature Range(°C) | -20::60 |
|---|---|---|---|---|---|
| Number of Solenoids | Single Solenoid | Application | Single Item | IP | IP65 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy