Pilot Operated 2 Port Solenoid Valve VXD Series (Part Numbers)

Pilot Operated 2 Port Solenoid Valve VXD Series

SMC Solenoid Valve.
[Features]
· IP65 protective enclosure
· UL94V-0 conforming flame resistance
· Low noise construction
· Piping variations
· Clearance
· Improved armature durability

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

  • Product images may be representative images. Refer to the catalog for details.

PDF

Pilot Operated 2 Port Solenoid Valve VXD Series Features

Valve SpecificationsValve StructurePilot operated 2 port diaphragm type
Withstand Pressure2.0 MPa (resin body type: 1.5 MPa)
Body MaterialAluminum, resin, C37, SUS, CAC408
Seal MaterialsNBR, FKM, EPDM*3
EnclosureDustproof, jetproof (IP65)*1, *4
EnvironmentLocations without corrosive or explosive gases
Coil SpecificationsRated VoltageAC100 V AC, 200 V AC, 110 V AC, 230 V AC, (220 V AC, 240 V AC, 48 V AC, 24 V AC)*2
DC24 V DC, (12 V DC)*2
Allowable Voltage Fluctuation±10% of rated voltage
Allowable Leakage VoltageAC5% or less of rated voltage
DC2% or less of rated voltage
Coil Insulation TypeClass B, class H

*1: Electrical entry "Faston" type terminal is IP40 compliant
*2 Voltage inside () indicates special voltage. (See the SMC catalog)
*3: See the catalog regarding seal material EPDM.
*4: See the SMC catalog glossary for information on protection grades. Contact the SMC support center regarding use in locations that require water resistance.

  • *Be sure to read the individual product precautions before use.

Diagram

Normally closed (N.C.)

VXD23 diagram

VXD23 diagram

VXD24 diagram

VXD24 diagram

VXD25/26 diagram

VXD25/26 diagram

VXD27/28/29 diagram

VXD27/28/29 diagram

Component Part Materials

NumberPart NameModelMaterial
1BodyVXD23C37, SUS, Aluminum, resin (PBT)
VXD24 to 26C37, SUS
VXD27 to 29CAC408
2BonnetVXD23/24SUS
VXD25, 26C37, SUS
VXD27 to 29CAC408
3Diaphragm AssemblyVXD23 to 29SUS, NBR, FKM, EPDM
4SpringVXD23 to 29SUS
5O-RingVXD23 to 26NBR, FKM, EPDM
6BufferVXD23/24PPS
7StopperVXD23 to 29NBR, FKM, EPDM
8Armature CoreFe
9TubeSUS
10SpringSUS
11Armature AssemblySUS, NBR, FKM, EPDM, resin (PPS)
12Solenoid CoilCu + Fe + resin

Operation

  • Valve Opening
    When the coil (12) is energized, the armature assembly (11) is attracted by the core (8), opening the pilot valve (A).
    When (A) is opened, the pressure in the pressure action chamber (B) falls, opening the main valve (C).
  • Valve Closing
    When the coil (12) is not energized, the pilot valve (A) closes and the pressure in the pressure action chamber (B) increases, closing the main valve (C).

Normally Open (N.O.)

VXD2A diagram

VXD2A diagram

VXD2B diagram

VXD2B diagram

VXD2C/2D diagram

VXD2C/2D diagram

VXD2E, 2F, 2G diagram

VXD2E, 2F, 2G diagram

Component Part Materials

NumberPart NameModelMaterial
1BodyVXD2AC37, SUS, Aluminum, resin (PBT)
VXD2B to 2DC37, SUS
VXD2E to 2GCAC408
2BonnetVXD2A, 2BSUS
VXD2C, 2DC37, SUS
VXD2E to 2GCAC408
3Diaphragm AssemblyVXD2A to 2GSUS, NBR, FKM, EPDM
4SpringVXD2A to 2GSUS
5O-RingVXD2A to 2DNBR, FKM, EPDM
6BufferVXD2A, 2BPPS
7Sleeve AssemblyVXD2A to 2GSUS, resin (PPS)
8Push Rod AssemblyResin (PPS), SUS, NBR, FKM, EPDM
9SpringSUS
10O-Ring ANBR, FKM, EPDM
11O-Ring BNBR, FKM, EPDM
12AdapterResin (PPS)
13O-Ring CNBR, FKM, EPDM
14Solenoid CoilCu + Fe + resin

Operation

  • Valve Opening
    When the coil (14) is energized, the opened pilot valve (A) closes and the pressure in the pressure action chamber (B) increases, closing the main valve (C).
  • Valve Closing
    When the coil (14) is not energized, the closed pilot valve (A) opens and the pressure in the pressure action chamber (B) drops, opening the main valve (C).
  • *See the SMC catalog for other models.
Part Number
VXD230CZ2EXB
VXD230CZ2G
VXD230CZ2J
VXD230CZ2KXB
VXD230CZ2KXCC
VXD230CZ2L
VXD230CZ2LXB
VXD230CZ3AB
VXD230CZ3AXCC
VXD230CZ3CB
VXD230CZ3D
VXD230CZ3EA
VXD230CZ3VAXB
VXD230DA
VXD230DAC
VXD230DAXCA
VXD230DB
VXD230DBZ
VXD230DC
VXD230DE
VXD230DG
VXD230DQ
VXD230DV
VXD230DZ1B
VXD230DZ1D
VXD230DZ1E
VXD230DZ2A
VXD230DZ2AC
VXD230DZ2AZ
VXD230DZ2N
VXD230EA
VXD230EZ1B
VXD230EZ2A
VXD230FA
VXD230FAH
VXD230FAZ
VXD230FB
VXD230FFXCC
VXD230FG
VXD230FJ
VXD230FQ
VXD230FZ1VC
VXD230FZ2A
VXD230FZ2AC
VXD230FZ2AXCC
VXD230FZ2AZXCC
VXD230FZ2D
VXD230FZ2K
VXD230FZ2N
VXD240GA
VXD240GAXB
VXD240GB
VXD240GBXB
VXD240GC
VXD240GD
VXD240GE
VXD240GF
VXD240GFXB
VXD240GG
VXD240GGA
VXD240GGAXB
VXD240GGAXBC
VXD240GGB
VXD240GGXB
VXD240GGXCB
VXD240GH
VXD240GHC
VXD240GHXBA
VXD240GHXBB
VXD240GHXCB
VXD240GJ
VXD240GJBXB
VXD240GK
VXD240GL
VXD240GM
VXD240GMXB
VXD240GMXCB
VXD240GMZ
VXD240GN
VXD240GNXB
VXD240GNZ
VXD240GS
VXD240GSXB
VXD240GT
VXD240GV
VXD240GZ1B
VXD240GZ1BB
VXD240GZ1BXB
VXD240GZ1C
VXD240GZ1EXB
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipApplicable Fluid Plumbing Thread Nominal Operating Environment Switching Type Connection Type Tube Dia. Tube Flange Nominal Orifice Dia.
(Ø)
Operating Pressure Differential Range
(MPa)
Insulation Class Pipe opening type (details) Voltage Sealing materials Lead wire exit direction Option Body material Bracket Detailed type Functions Lead wire electrical entry

MYR 397.51

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--100.02~0.9BNone230 V DCNBRStandardNoneAluminumIncludedFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 339.18

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--100.02~0.9BNone220 V ACNBRNoneNoneAluminumNoneFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 339.18

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--100.02~0.7BNone12 V DCNBRNoneNoneAluminumNoneFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 366.53

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--100.02~0.7BNone24 V DCNBRStandardNoneAluminumIncludedFor airWith lightConduit terminal (With surge voltage suppressor)

MYR 385.92

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--100.02~0.7BNone24 V DCNBR270°NoneAluminumNoneFor airWith lightConduit terminal (With surge voltage suppressor)

MYR 328.54

1 Piece(s) 10 Day(s) or more Air1/2Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--100.02~0.9BNone100 V ACNBRNoneNoneAluminumNoneFor airWith lightConduit terminal (With surge voltage suppressor)

MYR 349.55

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--100.02~0.9BNone100 V ACNBRStandardNoneAluminumIncludedFor airWith lightConduit terminal (With surge voltage suppressor)

MYR 313.93

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally ClosedNPT--100.02~0.7BNone24 V DCNBRNoneNoneAluminumNoneFor airWithout DIN connectorDIN terminal (With surge voltage suppressor)

MYR 297.51

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--100.02~0.7BNone24 V DCNBR270°NoneAluminumNoneFor airWithout DIN connectorDIN terminal (With surge voltage suppressor)

MYR 330.78

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally ClosedNPT--100.02~0.9BNone110 V ACNBRNoneNoneAluminumNoneFor airWithout DIN connectorDIN terminal (With surge voltage suppressor)

MYR 313.93

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--100.02~0.9BNone200 V ACNBRNoneNoneAluminumNoneFor airWithout DIN connectorDIN terminal (With surge voltage suppressor)

MYR 284.82

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally ClosedG--100.02~0.9BNone230 V DCNBRNoneNoneAluminumNoneFor airWithout DIN connectorDIN terminal (With surge voltage suppressor)

MYR 350.10

1 Piece(s) 23 Day(s) or more Air1/2Standard / Dust Resistant / Jet Proof TypeNormally ClosedG--100.02~0.9BNone24 V DCNBRStandardNoneAluminumIncludedFor airWithout DIN connectorDIN terminal (With surge voltage suppressor)

MYR 222.42

1 Piece(s) 10 Day(s) or more Air-Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.7BWith one-touch fitting24 V DCNBRNoneNoneResinNoneFor airNoneGrommet

MYR 334.30

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.7BWith one-touch fitting24 V DCFKMNoneCompatible with low concentration ozone, deionized water, etc.ResinNoneFor airNoneGrommet

MYR 260.93

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.7BWith one-touch fitting24 V DCNBR90°NoneResinNoneFor airNoneGrommet

MYR 222.42

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.9BWith one-touch fitting100 V ACNBRNoneNoneResinNoneFor airNoneGrommet (With surge voltage suppressor)

MYR 279.15

1 Piece(s) 23 Day(s) or more Air-Standard / No oil / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.9BWith one-touch fitting100 V ACNBRNoneOil-freeResinNoneFor airNoneGrommet (With surge voltage suppressor)

MYR 222.42

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.9BWith one-touch fitting110 V ACNBRNoneNoneResinNoneFor airNoneGrommet (With surge voltage suppressor)

MYR 222.42

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.9BWith one-touch fitting230 V DCNBRNoneNoneResinNoneFor airNoneGrommet (With surge voltage suppressor)

MYR 271.63

1 Piece(s) 10 Day(s) or more Air-Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.7BWith one-touch fitting24 V DCNBRNoneNoneResinNoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 309.29

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.9BWith one-touch fitting200 V ACNBRNoneNoneResinNoneFor airNoneConduit terminal (With surge voltage suppressor)

MYR 269.82

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.9BWith one-touch fitting200 V ACNBRNoneNoneResinNoneFor airNoneConduit (With surge voltage suppressor)

MYR 222.42

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.9BWith one-touch fitting220 V ACNBRNoneNoneResinNoneFor airSpecial voltageGrommet (With surge voltage suppressor)

MYR 222.42

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.7BWith one-touch fitting12 V DCNBRNoneNoneResinNoneFor airSpecial voltageGrommet

MYR 266.76

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.7BWith one-touch fitting12 V DCNBRNoneNoneResinNoneFor airSpecial voltageGrommet (With surge voltage suppressor)

MYR 310.48

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.7BWith one-touch fitting24 V DCNBRNoneNoneResinNoneFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 415.18

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.7BWith one-touch fitting24 V DCFKMNoneCompatible with low concentration ozone, deionized water, etc.ResinNoneFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 353.40

1 Piece(s) 23 Day(s) or more Air-Standard / No oil / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.7BWith one-touch fitting24 V DCNBRNoneOil-freeResinNoneFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 331.60

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ10-100.02~0.9BWith one-touch fitting200 V ACNBRNoneNoneResinNoneFor airWith lightConduit terminal (With surge voltage suppressor)

MYR 222.42

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ9.52-100.02~0.7BWith one-touch fitting24 V DCNBRNoneNoneResinNoneFor airNoneGrommet

MYR 222.42

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ9.52-100.02~0.9BWith one-touch fitting220 V ACNBRNoneNoneResinNoneFor airSpecial voltageGrommet (With surge voltage suppressor)

MYR 310.48

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube ConnectionØ9.52-100.02~0.7BWith one-touch fitting24 V DCNBRNoneNoneResinNoneFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 222.42

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.7BWith one-touch fitting24 V DCNBRNoneNoneResinNoneFor airNoneGrommet

MYR 326.84

1 Piece(s) 23 Day(s) or more Air-Standard / No oil / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.7BWith one-touch fitting24 V DCFKMNoneCompatible with low concentration ozone, deionized water, etc. / Oil-freeResinNoneFor airNoneGrommet

MYR 256.23

1 Piece(s) 23 Day(s) or more Air-Standard / No oil / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.7BWith one-touch fitting24 V DCNBRNoneOil-freeResinNoneFor airNoneGrommet

MYR 222.42

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.9BWith one-touch fitting100 V ACNBRNoneNoneResinNoneFor airNoneGrommet (With surge voltage suppressor)

MYR 326.47

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.7BWith one-touch fitting24 V DCNBR270°NoneResinNoneFor airNoneGrommet (With surge voltage suppressor)

MYR 271.63

1 Piece(s) 10 Day(s) or more Air-Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.7BWith one-touch fitting24 V DCNBRNoneNoneResinNoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 271.63

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.9BWith one-touch fitting110 V ACNBRNoneNoneResinNoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 309.29

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.9BWith one-touch fitting200 V ACNBRNoneNoneResinNoneFor airNoneConduit terminal (With surge voltage suppressor)

MYR 381.61

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.9BWith one-touch fitting24 V DCFKMNoneCompatible with low concentration ozone, deionized water, etc.ResinNoneFor airSpecial voltageDIN terminal (With surge voltage suppressor)

MYR 310.48

1 Piece(s) 10 Day(s) or more Air-Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.7BWith one-touch fitting24 V DCNBRNoneNoneResinNoneFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 421.05

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.7BWith one-touch fitting24 V DCFKMNoneCompatible with low concentration ozone, deionized water, etc.ResinNoneFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 370.12

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.7BWith one-touch fitting24 V DCNBR270°NoneResinNoneFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 378.00

1 Piece(s) 23 Day(s) or more Air-Standard / No oil / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.7BWith one-touch fitting24 V DCNBR270°Oil-freeResinNoneFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 344.56

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.9BWith one-touch fitting200 V ACNBRNoneNoneResinNoneFor airWith lightDIN terminal (With surge voltage suppressor)

MYR 331.60

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.7BWith one-touch fitting24 V DCNBRNoneNoneResinNoneFor airWith lightConduit terminal (With surge voltage suppressor)

MYR 331.60

1 Piece(s) 23 Day(s) or more Air-Standard / Dust Resistant / Jet Proof TypeNormally ClosedTube Connectionø12-100.02~0.9BWith one-touch fitting200 V ACNBRNoneNoneResinNoneFor airWith lightConduit terminal (With surge voltage suppressor)

MYR 429.45

1 Piece(s) 10 Day(s) or more Air3/8Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBRNoneNoneC37NoneFor airNoneGrommet

MYR 475.38

1 Piece(s) 10 Day(s) or more Air3/8Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBRStandardNoneC37IncludedFor airNoneGrommet

MYR 450.23

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone100 V ACNBRNoneNoneC37NoneFor airNoneGrommet (With surge voltage suppressor)

MYR 455.27

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone100 V ACNBRStandardNoneC37IncludedFor airNoneGrommet (With surge voltage suppressor)

MYR 429.45

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone110 V ACNBRNoneNoneC37NoneFor airNoneGrommet (With surge voltage suppressor)

MYR 429.45

1 Piece(s) 10 Day(s) or more Air3/8Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone200 V ACNBRNoneNoneC37NoneFor airNoneGrommet (With surge voltage suppressor)

MYR 429.36

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone230 V DCNBRNoneNoneC37NoneFor airNoneGrommet (With surge voltage suppressor)

MYR 473.67

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBRNoneNoneC37NoneFor airNoneGrommet (With surge voltage suppressor)

MYR 499.49

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBRStandardNoneC37IncludedFor airNoneGrommet (With surge voltage suppressor)

MYR 478.48

1 Piece(s) 23 Day(s) or more Air3/8Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBRNoneNoneC37NoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 478.48

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally ClosedG--150.02~1BNone24 V DCNBRNoneNoneC37NoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 504.53

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally ClosedG--150.02~1BNone24 V DCNBRStandardNoneC37IncludedFor airNoneDIN terminal (With surge voltage suppressor)

MYR 559.34

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally ClosedG--150.02~1BNone24 V DCNBR270°NoneC37IncludedFor airNoneDIN terminal (With surge voltage suppressor)

MYR 478.48

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally ClosedNPT--150.02~1BNone24 V DCNBRNoneNoneC37NoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 504.53

1 Piece(s) 10 Day(s) or more Air3/8Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBRStandardNoneC37IncludedFor airNoneDIN terminal (With surge voltage suppressor)

MYR 535.70

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBR180°NoneC37NoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 478.48

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone100 V ACNBRNoneNoneC37NoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 591.28

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone100 V ACFKMNoneCompatible with low concentration ozone, deionized water, etc.C37NoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 559.34

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone100 V ACNBR90°NoneC37IncludedFor airNoneDIN terminal (With surge voltage suppressor)

MYR 559.34

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone100 V ACNBR180°NoneC37IncludedFor airNoneDIN terminal (With surge voltage suppressor)

MYR 535.70

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone100 V ACNBR180°NoneC37NoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 478.48

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone110 V ACNBRNoneNoneC37NoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 547.20

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally ClosedNPT--150.02~1BNone110 V ACNBRStandardNoneC37IncludedFor airNoneDIN terminal (With surge voltage suppressor)

MYR 478.48

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone200 V ACNBRNoneNoneC37NoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 478.48

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone230 V DCNBRNoneNoneC37NoneFor airNoneDIN terminal (With surge voltage suppressor)

MYR 486.35

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBRNoneNoneC37NoneFor airNoneConduit terminal (With surge voltage suppressor)

MYR 512.17

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBRStandardNoneC37IncludedFor airNoneConduit terminal (With surge voltage suppressor)

MYR 543.63

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBR180°NoneC37NoneFor airNoneConduit terminal (With surge voltage suppressor)

MYR 539.32

1 Piece(s) 23 Day(s) or more Air3/8Standard / No oil / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBRNoneOil-freeC37NoneFor airNoneConduit terminal (With surge voltage suppressor)

MYR 486.35

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone100 V ACNBRNoneNoneC37NoneFor airNoneConduit terminal (With surge voltage suppressor)

MYR 512.17

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone100 V ACNBRStandardNoneC37IncludedFor airNoneConduit terminal (With surge voltage suppressor)

MYR 539.32

1 Piece(s) 23 Day(s) or more Air3/8Standard / No oil / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone100 V ACNBRNoneOil-freeC37NoneFor airNoneConduit terminal (With surge voltage suppressor)

MYR 450.40

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBRNoneNoneC37NoneFor airNoneConduit (With surge voltage suppressor)

MYR 476.22

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone24 V DCNBRStandardNoneC37IncludedFor airNoneConduit (With surge voltage suppressor)

MYR 450.40

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone100 V ACNBRNoneNoneC37NoneFor airNoneConduit (With surge voltage suppressor)

MYR 450.40

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone200 V ACNBRNoneNoneC37NoneFor airNoneConduit (With surge voltage suppressor)

MYR 429.45

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone220 V ACNBRNoneNoneC37NoneFor airSpecial voltageGrommet (With surge voltage suppressor)

MYR 429.45

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally ClosedNPT--150.02~1BNone220 V ACNBRNoneNoneC37NoneFor airSpecial voltageGrommet (With surge voltage suppressor)

MYR 455.27

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone220 V ACNBRStandardNoneC37IncludedFor airSpecial voltageGrommet (With surge voltage suppressor)

MYR 476.25

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone240 V ACNBRNoneNoneC37NoneFor airSpecial voltageGrommet (With surge voltage suppressor)

MYR 543.63

1 Piece(s) 23 Day(s) or more Air3/8Standard / Dust Resistant / Jet Proof TypeNormally Closed[Rc (R)] Rc--150.02~1BNone12 V DCNBRStandardNoneC37IncludedFor airSpecial voltageGrommet (With surge voltage suppressor)

Loading...

Basic Information

Type Electromagnetic Type Driving Type Pilot Type Operating Temperature Range(°C) -20::60
Number of Solenoids Single Solenoid Application Single Item IP IP65