· Easily set with DIP switch
· Two alarm types ave been added to the series. Ideal for alarm applications
· Multi-input (thermocouple / platinum temperature-sensing resistance) types are also available
· Easy-to-read digital display with character height of 13.5 mm
Part Number
Configured Part Number is shown.
E5CS-R1GU-W AC100-240
![Thermac S Electronic Temperature Controller [E5CS] External Shape Figure](http://content.misumi-ec.com/image/upload/t_msmwm_wyg/v1/p/jp/product/wysiwyg/221005345541/221005345541_001_20230801115855.jpg)
*The external dimensions are the same for both the type without alarm and the type with alarm.
![Thermac S Electronic Temperature Controller [E5CS] External Shape Figure (No Alarm Type)](http://content.misumi-ec.com/image/upload/t_msmwm_wyg/v1/p/jp/product/wysiwyg/221005345541/221005345541_002_20230801115855.jpg)
Type without alarm
![Thermac S Electronic Temperature Controller [E5CS] External Shape Figure (With Alarm Type)](http://content.misumi-ec.com/image/upload/t_msmwm_wyg/v1/p/jp/product/wysiwyg/221005345541/221005345541_003_20230801115855.jpg)
Type with alarm
| Power supply voltage | 100 to 240 V AC 50/60 Hz 24 V AC 50/60 Hz / 24 V DC | |
|---|---|---|
| Allowable Voltage Fluctuation Range | 85 to 110% of power supply voltage | |
| Power consumption | 5 VA (100 to 240 V AC) 3 VA (24 V AC) / 2 W (24 V DC) | |
| Input | Thermocouple type: K, J, L Platinum resistance thermometer type: Pt100, JPt100 Thermistor type: Model E52-THE** Multi-input type for thermocouples and platinum resistance thermometers : K, J, L, T, U, N, R, Pt100, JPt100 | |
| Control output | relay output | 250 V AC 3 A (resistive load) 1c |
| Voltage output (for SSR drive) | 12 V DC 21 mA (with short circuit protection circuit) | |
| Control method | ON/OFF, 2 flexibility PID (with automatic PID parameter setting function) shared | |
| Alarm output | 250 V AC 1 A (resistive load) 1a | |
| Setting Method | Digital setting with front keys | |
| Display Type | 7-segment digital display (character height 13.5 mm) and deviation indication | |
| Other functions | · Setting change prohibition (key protect) · Input correction · Display unit switching (°C/°F) · Direct/reverse operation switching · Temperature range, sensor switching (K/J/L, Pt100/JPt100), For thermocouple/platinum resistance thermometer multi-input types, switching between thermocouple and platinum resistance thermometer · Control Cycle switching · 8-mode alarm output · Sensor abnormality detection (excluding thermistor type) | |
| Operating ambient temperature | -10 to +55°C (no freezing or condensation) / For 3-year warranty: -10 to +50°C | |
| Operating ambient humidity | Relative humidity 25 to 85% | |
| Storage temperature | -25 to +65°C (no freezing or condensation) | |
note. Do not use the output of an inverter as the power supply.
| Indication Accuracy (ambient temperature 23°C) | thermocouple: *1 (+/-1% of indicated value or +/-2°C, whichever is larger) +/- 1 digit or less platinum resistance thermometer: *2 (+/-0.5% of indicated value or +/-1°C, whichever is larger) +/- 1 digit or less Thermistor: *3 (1% FS) +/- 1 digit or less | |
|---|---|---|
| Effect of temperature | Thermocouple (R): (+/-2% PV or +/-10°C, whichever is greater) +/- 1 digit or less Other thermocouples: (+/-2% PV or +/-4°C, whichever is greater) +/- 1 digit or less Platinum resistance thermometer: (+/-1% PV or +/-2°C, whichever is greater) +/- 1 digit or less Thermistor: (+/-2%FS) +/-1 digit or less | |
| Effect of voltage | ||
| Effect of electromagnetic interference (according to EN61326-1) | ||
| Control sensitivity (When ON/OFF control) | 0.2%FS (For thermocouple/platinum resistance thermometer multi-input type: 0.1%FS) | |
| Proportional Band | 1 to 999°C (automatically set by self-tuning or auto-tuning) | |
| Integration Time | 1–1999 s (Automatically set by self-tuning or auto-tuning) | |
| Derivative Time | 1–1999 s (Automatically set by self-tuning or auto-tuning) | |
| Alarm Output Setting Range | Absolute value alarm: Same as control setting range Others: 0 to input setting range full scale [Unit: °C or°F] Alarm hysteresis: 0.2°C or°F (fixing) | |
| Control Cycle | 2/20 s | |
| Sampling period | 500 ms | |
| Insulation resistance | 20 MΩ or more (500 V DC insulation resistance tester) | |
| Withstand voltage | 2,000 V AC 50/60 Hz for 1 min (between terminals of different live parts) | |
| Vibration resistance | Malfunction | 10 to 55 Hz, 20 m/s2, 10 min in each direction of X, Y, and Z |
| Endurance | 10 to 55 Hz, 0.75 mm in each direction of X, Y, and Z for 2 hr | |
| Impact resistant | Malfunction | 100 m/s2 6 directions, 3 times each |
| Endurance | 300 m/s2 6 directions, 3 times each | |
| Lifespan | Electrical | Over 100,000 times (relay output type) |
| Weight | approx. 110 g (main body only) | |
| Protective Structure | Front: IP50, enclosure category 2 (according to IEC60529), rear case: IP20, terminal: IP00 | |
| Memory Protection | Non-volatile memory (write cycles: 1,000,000 times) | |
| EMC | Radiated emission field strength EN55011 Group 1 Class A Terminal noise voltage EN55011 Group 1 Class A ESD immunity EN61000-4-2 : 4 kV contact electric discharge (Level 2) 8 kV air electric discharge (Level 3) Electric field strength immunity EN61000-4-3 : 10 V/m (80–1,000 MHz, 1.4–2.0 GHz amplitude modulation) (Level 3) 10 V/m (900 MHz pulse modulation) Conducted Disturbance Immunity EN61000-4-6 : 3 V (0.15–80 MHz) (Level 2) Fast Transient EN61000-4-4 Burst Noise Immunity: 2 kV Power Line (Level 3) 1 kV Input/Output Signal Line (Level 3) Surge Immunity EN61000-4-5 : Power line Normal mode 1 kV Common mode 2 kV Output line (relay output) Normal mode 1 kV Common mode 2 kV Voltage dip/interruption immunity EN61000-4-11 : 0.5 cycle, 100% (rated voltage) | |
| Certification Standards | UL61010-1 (Listing supported) CSA C22.2 No.1010-1 | |
| Applicable standards | EN61326-1, EN61010-1, IEC61010-1 | |
| Part Number |
|---|
| E5CS-R1GU-W AC100-240 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Input Method | Control Method | Output Type | Number of Control Points | Setting Method | Failure Detecting Function | Power Supply Voltage (V) | Control Output 1 | Case Color | Alarm Output |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,059.23 | 1 Piece(s) | 9 Day(s) or more | Thermistor | - | - | - | - | - | 100 to 240 AC | Relay | Light gray | 1 alarm |
Loading...
| Number of Input Points(pcs.) | 1 |
|---|
Please check the type/dimensions/specifications of the part E5CS-R1GU-W AC100-240 in the Thermac S Electronic Temperature Controller [E5CS] series.
| Part Number |
|---|
| E5CS-QGU-W AC100-240 |
| E5CS-QKJU-W AC100-240 |
| E5CS-QPU-W AC100-240 |
| E5CS-R1KJDU-W AC/DC24 |
| E5CS-R1KJU-W AC100-240 |
| E5CS-R1PDU-W AC/DC24 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Input Method | Control Method | Output Type | Number of Control Points | Setting Method | Failure Detecting Function | Power Supply Voltage (V) | Control Output 1 | Case Color | Alarm Output |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 966.46 | 1 Piece(s) | 9 Day(s) or more | Thermistor | - | - | - | - | - | 100 to 240 AC | Voltage output (for driving SSR) | Light gray | No alarm | ||
MYR 966.46 | 1 Piece(s) | 5 Day(s) or more | Thermocouple | - | - | - | - | - | 100 to 240 AC | Voltage output (for driving SSR) | Light gray | No alarm | ||
MYR 1,289.41 | 1 Piece(s) | 9 Day(s) or more | Platinum temperature measuring resistor | - | - | - | - | - | 100 to 240 AC | Voltage output (for driving SSR) | Light gray | No alarm | ||
MYR 1,059.23 | 1 Piece(s) | 5 Day(s) or more | Thermocouple | - | - | - | - | - | 24 AC/DC | Relay | Light gray | 1 alarm | ||
MYR 1,059.23 | 1 Piece(s) | 9 Day(s) or more | Thermocouple | - | - | - | - | - | 100 to 240 AC | Relay | Light gray | 1 alarm | ||
MYR 1,059.23 | 1 Piece(s) | 9 Day(s) or more | Platinum temperature measuring resistor | - | - | - | - | - | 24 AC/DC | Relay | Light gray | 1 alarm |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy