(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Thermac NEO series, one of the best-selling temperature controller, from model selection to operation and maintenance.
A high-performance type that responds to higher-speed, higher-accuracy temperature and process control, and a program type that expands the range of compatible applications are also available.
Part Number
Configured Part Number is shown.
![Thermac NEO temperature controller (digital controller) [E5□N-H/E5□N-HT] E5CN-H type external shape figure](http://my.misumi-ec.com/linked/vitem/mech/OMR1/221005345529/img/221005345529_01.jpg)
note: Terminal unit cannot be removed.
E5CN-H type
![Thermac NEO temperature controller (digital controller) [E5□N-H/E5□N-HT] E5CN-H type parts identification figure](http://my.misumi-ec.com/linked/vitem/mech/OMR1/221005345529/img/221005345529_02.jpg)
E5CN-H type rating
| Power supply voltage | Type without D power supply voltage: AC100 to 240 V 50/60 Hz Type with D power supply voltage: 24 V AC 50/60 Hz / 24 V DC | |
|---|---|---|
| Allowable Voltage Fluctuation Range | 85 to 110% of power supply voltage | |
| Power consumption | When using AC100–240 V: 8.5 VA (Max.) (3.0 VA for model E5CN-HR2 at 100 V AC) When using AC/24 V DC: 5.5 VA (24 V AC) / 3.5 W (24 V DC) (Max.) (2.7 VA for model E5CN-HR2D at 24 V AC) | |
| Sensor input | Selectable from the following (fully multi input). Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII Platinum resistance thermometer: Pt100, JPt100 Current input: 4 to 20 mA, 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V | |
| Input impedance | Current input: 150 Ω or less, voltage input: 1 MΩ or more (When connecting model ES2-HB-N, please use a 1:1 connection.) | |
| Control method | ON/OFF or 2-degree-of-freedom PID (with auto-tuning) | |
| Control output | relay output | 1a 250 V AC 3 A (resistive load) electrical lifespan: 100,000 cycles minimum applicable load: 5 V 10 mA |
| Voltage output (for SSR drive) | output voltage 12 V DC ±15% (PNP) Max. load current 21 mA, with short circuit protection circuit | |
| Current output | DC 4–20 mA/DC 0–20 mA load 600 Ω or less resolution approx. 10,000* | |
| Linear voltage output | DC 0–10 V (load 1 kΩ or more) Resolution: approx. 10,000 | |
| Auxiliary output | Number of contacts | Max. 2 contacts |
| Output specifications | Relay output 1a 250 V AC 3 A (resistive load) Electrical lifespan: 100,000 cycles Minimum applicable load: 5 V 10 mA | |
| Event input | Number of contacts | Max. 2 points (depending on model: only for types with event input B) |
| External contact input specifications | For contact input: ON: 1 kΩ or less OFF: 100 kΩ or more | |
| For non-contact input: ON: residual voltage 1.5 V or less OFF: leakage current 0.1 mA or less | ||
| Output current: approx. 7 mA (per contact) | ||
| Simple Calculation | Number of Calculation Formulas | Max. 8 (can be combined via internal auxiliary relays) |
| Calculation | · Logical operation: Any one of the following four patterns can be selected. Each contact can be inverted. (A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D (A, B, C, and D are the four input points). · Delay: On-delay or off-delay can be applied to the above logic operation results. Setting time: 0–9999 seconds or 0–9999 minutes · Output inversion: Supported | |
| Output | 1 internal auxiliary relay per calculation formula | |
| Assignment of internal auxiliary relays | Up to 8 internal auxiliary relays (simple calculation results) can be assigned as follows: Event input operation, auxiliary output, or control output | |
| transfer output | Number of contacts | Maximum 1 point (depending on model: type with transfer output F) |
| Output specifications | Current output: DC 4–20 mA Load: 600 Ω or less Resolution: approx. 10,000 at 4–20 mA | |
| RSP input | Not Included | |
| Setting Method | Digital setting with front keys | |
| Display Type | 11-segment digital display and single-point light display (7-segment display also available) Character height PV: 11 mm, SV: 6.5 mm | |
| Bank Switching function | Included (Number of banks: 8) Local SP, alarm set values, PID group No. (PID constants, upper/lower limits for manipulated variable, etc.) | |
| Other functions | Manual output, heating/cooling control, loop break alarm function, SP lamp, alarm function, heater disconnection detection function (including SSR failure and heater overcurrent detection function), 40% AT, 100% AT, manipulated variable limit, input digital filter, self-tuning, temperature input correction, run/stop, protect, control output ON/OFF count function, square root calculation function, manipulated variable rate-of-change limit, PV/SV status display function, simple program function, automatic adjustment of cooling coefficient, etc. | |
| Operating ambient temperature | -10 to +55°C (no condensation or freezing) / For 3-year warranty: -10 to +50°C | |
| Operating Ambient Humidity | Relative humidity 25 to 85% | |
| Storage temperature | -25 to +65°C (no condensation or freezing) | |
*For current output type, control output 1 can also be used as a transmission output.
E5CN-H Type Performance
| Indication Accuracy | Thermocouple: (±0.1% of indicated value or ±1°C, whichever is greater) within ±1 digit*1 Platinum resistance thermometer: (±0.1% of indicated value or ±0.5°C, whichever is greater) within ±1 digit analog input: +/-0.1%FS +/-1 digit or less CT input: +/-5%FS +/-1 digit or less | ||
|---|---|---|---|
| Transmission output accuracy | Within +/-0.3%FS | ||
| Effect by Temperature*2 | Thermocouple input (R, S, B, W, PLII): (the greater of +/-1%PV or +/-10°C) +/-1 digit or less Other thermocouple input: (the greater of +/-1%PV or +/-4°C) +/-1 digit or less*3 Platinum resistance thermometer input: (the greater of +/-1%PV or +/-2°C) +/-1 digit or less analog input: (±1%FS) ±1 digit or less | ||
| Effect of voltage*2 | |||
| Effect of electromagnetic interference (according to EN61326-1) | |||
| Input sampling period | 60 ms | ||
| Control sensitivity | Temperature input: 0.1 to 3240.0°C or°F (in 0.1°C or°F increments) analog input: 0.01 to 99.99%FS (0.01%FS increments) | ||
| Proportional Band (P) | Temperature input: 0.1 to 3240.0°C or°F (in 0.1°C or°F increments) analog input: 0.1 to 999.9%FS (0.1%FS increments) | ||
| Integration Time (I) | 0.0 to 3240.0 s (0.1 s unit) | ||
| Derivative Time (D) | 0.0 to 3240.0 s (0.1 s unit) | ||
| Control Cycle | 0.5, 1 to 99 s (1 s increments) | ||
| Manual reset value | 0.0 to 100.0% (0.1% increments) | ||
| Alarm setting range | -19999 to 32400 (Decimal point position depends on input type) | ||
| Effect of signal source resistance | Thermocouple: 0.1°C/Ω or less (100 Ω or less), Platinum resistance thermometer: 0.1°C/Ω or less (10 Ω or less) | ||
| Insulation resistance | 20 MΩ or more (500 V DC insulation resistance tester) | ||
| Withstand voltage | 2,300 V AC 50 or 60 Hz 1 min (different-pole live parts terminals) | ||
| Vibration | Malfunction | 10 to 55 Hz, 20 m/s2, 10 min in 3-axis directions | |
| Endurance | 10 to 55 Hz, 0.75 mm single amplitude, 2 hr in 3-axis directions | ||
| Impact | Malfunction | 100 m/s2, 3-axis directions, 3 times each | |
| Endurance | 300 m/s2, 3-axis directions, 3 times each | ||
| Weight | main body: approx. 150 g installation: approx. 10 g | ||
| Protective Structure | Front: IP66, rear case: IP20, terminal: IP00 | ||
| Memory Protection | Non-volatile memory (write cycles: 1,000,000 times) | ||
| Setting Tool | CX-Thermo Ver.4.0 or higher | ||
| Port for Setting Tool | Bottom surface of E5CN-H: Connect between the PC-side USB port and the bottom surface port of E5CN-H using the USB-serial conversion cable E58-CIFQ1. *4 | ||
| Standard | Certification Standards | UL61010-1, CSA C22.2 No.1010-1 | |
| Applicable standards | EN61010-1 (IEC61010-1): Pollution degree 2, overvoltage category II, Lloyd's standard*5 | ||
| EMC Directive | EMI EN61326-1 *6 Radiated disturbance electric field strength EN55011 Group 1 class A Terminal noise voltage EN55011 Group 1 class A EMS EN61326-1 *6 Electrostatic Discharge Immunity EN61000-4-2 Electromagnetic Field Strength Immunity EN61000-4-3 Burst Noise Immunity EN61000-4-4 Conducted Disturbance Immunity EN61000-4-6 Surge immunity EN61000-4-5 Power supply frequency magnetic field immunity EN61000-4-8 Voltage dip/interruption immunity EN61000-4-11 | ||
*1. ±2°C ±1 digit or less for K (-200 to 1300°C range), T, N at -100°C or less, and U, L. No regulations for B of 400°C or less. ±3°C or less for B of 400 to 800°C.
+/-3°C +/-1 digit or less for R and S of 200°C or less. W: (+/-0.3% of PV or +/-3°C, whichever is larger) +/-1 digit or less.
PLII: (+/-0.3% of PV or +/-2°C, whichever is larger) +/-1 digit or less.
*2. Conditions: Ambient temperature: -10°C to 23°C to 55°C Voltage range: -15% to +10% of rated voltage
*3. For K sensors, below -100°C: within ±10°C
*4. Simultaneous use of external serial communication (RS-232C or RS-485) and configuration tool cable communication is possible
*5. For compliance with Lloyd's standards, please refer to page 144 of the digital catalog, "Compliance with Marine Standards."
*6. Industrial electromagnetic environment (EN/IEC61326-1 Table 2)
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Input Method | Output Type | Number of Control Points | Setting Method | Failure Detecting Function | Power Supply Voltage (V) | Control Output 1 | Control Output 2 | Event Input (Point) | Heater burnout / SSR failure / heater overcurrent detection function | Program type | Specifications | Communication | Transmission Output |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,825.23 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor | - | - | - | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit Method | Output Unit Method | 2 | Detection for single-phase heater | - | - | - | - | ||
MYR 1,771.35 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact / SSR Drive Output Voltage / Current / Linear Voltage | 2 | Key input / RSP Input | Heater Breakage / Heater Over current / SSR Breakdown | 24 AC/DC | Output Unit System | Output Unit Method | 2 | Detection for single-phase heater | - | 96×96 mm high-performance type | None | None | ||
MYR 3,316.33 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact / SSR Drive Output Voltage / Current / Linear Voltage | 2 | Key input / RSP Input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit System | Output Unit System | 2 | Detection for single or three-phase heater | - | 96×96 mm high-performance type | RS-232C, CompoWay/F | 1 | ||
MYR 2,174.75 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor | - | - | - | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit Method | Output Unit Method | 4 | Detection for single or three-phase heater | - | - | - | - | ||
MYR 2,330.09 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor | - | - | - | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit Method | Output Unit Method | 2 | Detection for single or three-phase heater | - | - | - | - | ||
MYR 1,831.91 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | - | - | - | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit Method | Output Unit Method | 2 | Detection for single-phase heater | Black type, three-stage display | - | - | - | ||
MYR 1,554.35 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Current | 1 | Key input | No | 100 to 240 VAC | Current output | No | None | None | - | 48×48 mm high-performance type | None | None | ||
MYR 1,670.37 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Current | 1 | Key input | No | 100 to 240 VAC | Current output | No | 2 | None | - | 48×48 mm high-performance type | None | None | ||
MYR 1,864.07 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Current | 1 | Key input | No | 100 to 240 VAC | Current output | No | 2 | None | - | 48×48 mm high-performance type | None | 1 | ||
MYR 1,865.99 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Current | 1 | Key input | No | 24 VAC/DC | Linear voltage output | No | 2 | None | - | 48×48 mm high-performance type | None | 1 | ||
MYR 1,360.94 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | SSR Drive Output Voltage | 1 | Key input | No | 100 to 240 VAC | Voltage output (for driving SSR) | No | None | None | - | 48×48 mm high-performance type | None | None | ||
MYR 1,670.37 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | SSR Drive Output Voltage | 1 | Key input | No | 100 to 240 VAC | Voltage output (for driving SSR) | No | 2 | None | - | 48×48 mm high-performance type | None | 1 | ||
MYR 1,864.07 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | SSR Drive Output Voltage | 1 | Key input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Voltage output (for driving SSR) | No | None | Detection for single-phase heater | - | 48×48 mm high-performance type | RS-232C, CompoWay/F | None | ||
MYR 1,795.74 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | SSR Drive Output Voltage | 1 | Key input | Heater Breakage / Heater Over current / SSR Breakdown | 24 AC/DC | Voltage output (for driving SSR) | NA | None | Detection for single-phase heater | - | 48×48 mm high-performance type | RS-232C, CompoWay/F | None | ||
MYR 2,358.46 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | SSR Drive Output Voltage | 1 | Key input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Voltage output (for driving SSR) | No | None | Detection for single-phase heater | - | 48×48 mm high-performance type | RS-485, CompoWay/F | None | ||
MYR 1,477.03 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | SSR Drive Output Voltage | 1 | Key input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Voltage output (for driving SSR) | No | 2 | Detection for single-phase heater | - | 48×48 mm high-performance type | None | None | ||
MYR 1,477.03 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | SSR Drive Output Voltage | 1 | Key input | Heater Breakage / Heater Over current / SSR Breakdown | 24 VAC/DC | Voltage output (for driving SSR) | No | 2 | Detection for single-phase heater | - | 48×48 mm high-performance type | None | None | ||
MYR 1,902.90 | 1 Piece(s) | 9 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | SSR Drive Output Voltage | 1 | Key input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Voltage output (for driving SSR) | No | None | Detection for single or three-phase heater | - | 48×48 mm high-performance type | RS-485, CompoWay/F | None | ||
MYR 1,515.65 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | SSR Drive Output Voltage | 2 | Key input | No | 100 to 240 VAC | Voltage output (for driving SSR) | Voltage Output (for SSR Drive) | 2 | None | - | 48×48 mm high-performance type | None | None | ||
MYR 1,711.28 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | SSR Drive Output Voltage | 2 | Key input | No | 100 to 240 VAC | Voltage output (for driving SSR) | Voltage Output (for SSR Drive) | None | None | - | 48×48 mm high-performance type | None | 1 | ||
MYR 1,360.94 | 1 Piece(s) | 2 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact | 1 | Key input | No | 100 to 240 VAC | Relay Output | No | 2 | None | - | 48×48 mm high-performance type | None | None | ||
MYR 2,110.78 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact | 1 | Key input | No | 100 to 240 VAC | Relay Output | No | 2 | None | - | 48×48 mm high-performance type | None | 1 | ||
MYR 1,670.37 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact | 1 | Key input | No | 24 VAC/DC | Relay Output | No | 2 | None | - | 48×48 mm high-performance type | None | 1 | ||
MYR 1,363.15 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact | 1 | Key input | No | 24 VAC/DC | Relay Output | No | None | None | - | 48×48 mm high-performance type | None | None | ||
MYR 1,864.07 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact | 1 | Key input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Relay Output | No | None | Detection for single-phase heater | - | 48×48 mm high-performance type | RS-232C, CompoWay/F | None | ||
MYR 1,904.46 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact | 1 | Key input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Relay Output | No | 2 | Detection for single-phase heater | - | 48×48 mm high-performance type | None | None | ||
MYR 1,902.90 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Linear Voltage | 1 | Key input | No | 100 to 240 VAC | Linear voltage output | No | 2 | None | - | 48×48 mm high-performance type | None | 1 | ||
MYR 1,593.04 | 1 Piece(s) | 9 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact / SSR Drive Output Voltage / Current / Linear Voltage | 2 | Key input / RSP Input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit System | Output Unit System | 2 | Detection for single-phase heater | - | 48×96 mm high-performance type | None | None | ||
MYR 2,063.09 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact / SSR Drive Output Voltage / Current / Linear Voltage | 2 | Key input / RSP Input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit System | Output Unit System | 2 | Detection for single or three-phase heater | - | 48×96 mm high-performance type | RS-422, CompoWay/F | None | ||
MYR 2,058.24 | 1 Piece(s) | 9 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact / SSR Drive Output Voltage / Current / Linear Voltage | 2 | Key input / RSP Input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit System | Output Unit System | 2 | Detection for single or three-phase heater | - | 48×96 mm high-performance type | RS-485, CompoWay/F | None | ||
MYR 2,901.91 | 1 Piece(s) | 97 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact / SSR Drive Output Voltage / Current / Linear Voltage | 2 | Key input / RSP Input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit System | Output Unit System | 2 | Detection for single or three-phase heater | - | 48×96 mm high-performance type | RS-485, CompoWay/F | 1 | ||
MYR 2,117.65 | 1 Piece(s) | 9 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact / SSR Drive Output Voltage / Current / Linear Voltage | 2 | Key input / RSP Input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit System | Output Unit System | 4 | Detection for single or three-phase heater | - | 48×96 mm high-performance type | None | None | ||
MYR 1,864.07 | 1 Piece(s) | 9 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact / SSR Drive Output Voltage / Current / Linear Voltage | 2 | Key input / RSP Input | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit System | Output Unit System | 2 | Detection for single or three-phase heater | - | 48×96 mm high-performance type | None | 1 | ||
MYR 1,801.37 | 1 Piece(s) | 5 Day(s) or more | Thermocouple / Platinum temperature measuring resistor / Voltage / Current | Relay contact / SSR Drive Output Voltage / Current / Linear Voltage | 2 | Key input / RSP Input | Heater Breakage / Heater Over current / SSR Breakdown | 24 AC/DC | Output Unit System | Output Unit Method | 2 | Detection for single or three-phase heater | - | 48×96 mm high-performance type | None | 1 |
Loading...
| Control Method | ON/OFF Control / PID control with auto tuning | Number of Input Points(pcs.) | 1 | Case Color | Black |
|---|---|---|---|---|---|
| Auxiliary Output Points | 2 |

OMRON
Standard Price : MYR 697.35-
Days to Ship : 1 Day(s) or more

MISUMI
Standard Price : MYR 412.19-
Days to Ship : 1 Day(s) or more

MISUMI
Standard Price : MYR 1,759.06-
Days to Ship : 1 Day(s) or more
![Temperature controller (digital controller) [E5EC/AC]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/221005345620.jpg?$product_recommend_b$)
OMRON
Standard Price : MYR 958.66-
Days to Ship : 2 Day(s) or more

THREE HIGH
Standard Price : MYR 303.30-
Days to Ship : 4 Day(s) or more

OMRON
Standard Price : MYR 184.99-
Days to Ship : 2 Day(s) or more

THREE HIGH
Standard Price : MYR 3,023.87
Days to Ship : 10 Day(s) or more

NIHONDENSOKU
Standard Price : MYR 165.05-
Days to Ship : 4 Day(s) or more

JUST
Standard Price : MYR 2,128.00
Days to Ship : 9 Day(s) or more

OMRON
Standard Price : MYR 166.99-
Days to Ship : 2 Day(s) or more

How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy