Non-contact temperature sensor ES1 (Part Numbers)

Drawing

ES1-LP3-N/ES1-LP10-N Main Body

Non-contact temperature sensor ES1 Model ES1-LP3-N / Model ES1-LP10-N External Shape Diagram

ES1-LW50-N/ES1-LW50L-N Main Body

Non-contact temperature sensor ES1 Model ES1-LW50-N / Model ES1-LW50L-N External Shape Diagram

(For ES1-LW50-N, there is no laser output port (6) or laser switch (7).)

ES1-LW100-N/ES1-LW100L-N Main Body

Non-contact temperature sensor ES1 Model ES1-LW100-N / Model ES1-LW100L-N External Shape Diagram

(For model ES1-LW100-N, there is no laser output port (6) or laser switch (7).)

ES1B

Non-contact temperature sensor ES1 Model ES1B external shape diagram

ES1C

Non-contact temperature sensor ES1 Model ES1C external shape diagram

Product Specification

ES1-N Rating / Performance

ES1-N

TypeWithout aiming laserWith aiming laser
Part numberModel ES1-LP3-NModel ES1-LP10-NModel ES1-LW50-NModel ES1-LW100-NModel ES1-LW50L-NModel ES1-LW100L-N
Detection elementThermopile
LensSilicone
Measurement wavelength8 to 14 μm
OutputUSB outputResolution: 0.1°C
Current output4 to 20 mA / -50 to 500°C *1
Load impedance 250Ω or less
Resolution 0.24μA
4 to 20 mA / -50 to 1,000°C *1
Load impedance 250Ω or less
Resolution 0.24μA
4 to 20 mA / -50 to 500°C *1
Load impedance 250Ω or less
Resolution 0.24μA
4–20 mA / -50 to 1,000°C *1
Load impedance 250Ω or less
Resolution 0.24μA
Power supply voltageDC12–24 V / USB bus power (Only outputs other than current output are available with USB bus power only)
Allowable power supply voltage fluctuation95–105% of power supply voltage
Current Consumption30 mA or less (at 24 V DC)· 30 mA or less (at 24 V DC, when the aiming laser is not in use)
· 40 mA or less (at 24 V DC, when the aiming laser is in use)
Cable length2 m ±5 cm
Measuring AccuracyUSB output
· within ±(-8% rdg + 1)°C
(measurement temperature: -50 to 0°C)
· within ±1°C
(measurement temperature: 0 to 200°C)
· within ±0.5% rdg°C
(200 to 500°C)
Current output
· Difference from USB output
Within (±0.1% output range)°C
USB output
· within ±(-8% rdg + 1)°C
(measurement temperature: -50 to 0°C)
· within ±1°C
(measurement temperature: 0 to 200°C)
· within ±0.5% rdg°C
(200 to 1,000°C)
Current output
· Difference from USB output
Within (±0.1% output range)°C
USB output
· within ±(-8% rdg + 1)°C
(measurement temperature: -50 to 0°C)
· within ±1°C
(measurement temperature: 0 to 200°C)
· within ±0.5% rdg°C
(200 to 500°C)
Current output
· Difference from USB output
Within (±0.1% output range)°C
USB output
· within ±(-8% rdg + 1)°C
(measurement temperature: -50 to 0°C)
· within ±1°C
(measurement temperature: 0 to 200°C)
· within ±0.5% rdg°C
(200 to 1,000°C)
Current output
· Difference from USB output
Within (±0.1% output range)°C
Repeatability· Within 0.5°C· Within 1°C
(measurement temperature: -50 to 0°C)
· Within 0.5°C
(Measurement temperature: 0 to 500°C)
· Within 1°C
(Measurement temperature: 500 to 1,000°C)
· Within 0.5°C· Within 1°C
(measurement temperature: -50 to 0°C)
· Within 0.5°C
(Measurement temperature: 0 to 500°C)
· Within 1°C
(Measurement temperature: 500 to 1,000°C)
Temperature drift· Within ±0.5°C/°C
(measurement temperature: -50 to 0°C)
· Within ±0.25°C/°C
(Measurement temperature: 0 to 500°C)
· Within ±0.5°C/°C
(measurement temperature: -50 to 0°C)
· Within ±0.25°C/°C
(Measurement temperature: 0 to 500°C)
· Within ±0.5°C/°C
(Measurement temperature: 500 to 1,000°C)
· Within ±0.5°C/°C
(measurement temperature: -50 to 0°C)
· Within ±0.25°C/°C
(Measurement temperature: 0 to 500°C)
· Within ±0.5°C/°C
(measurement temperature: -50 to 0°C)
· Within ±0.25°C/°C
(Measurement temperature: 0 to 500°C)
· Within ±0.5°C/°C
(Measurement temperature: 500 to 1,000°C)
Effects of electromagnetic interference*2Electromagnetic field electric discharge immunityWithin ±10°C (80 MHz to 1.0 GHz)
Conducted noise immunityWithin ±10°C (150 kHz to 80 MHz)
Response timeCurrent output: 0.14s or less (95% response, when moving average is 1)
Reflection RateFactory default: 0.95 Can be changed to 0.100–1.999 using the configuration tool
Moving average functionFactory default: 10
Can be changed to 1–1,000 using the configuration tool
Factory default: 50
Configurable to
1 to 1,000 using the configuration tool
Factory default: 10
Configurable to
1 to 1,000 using the configuration tool
Factory default: 50
Configurable to
1 to 1,000 using the configuration tool
Operating temperature and humidity rangeTemperature: 0 to 55°C, Humidity: 35 to 85% (no condensation)
Storage temperature range-20 to 55°C (no condensation)
Vibration resistanceMalfunction10 to 55 Hz, 20 m/s2, 10 min in 3-axis directions
Endurance10 to 55 Hz, 0.75 mm single amplitude, 2 hr in 3-axis directions
Protective structureN/A
Applicable standardsCE, KC, FCC, RCM
-IEC60825-1, PSC, FDA
External dimensionsW32 mm x H40 mm x L58 mmW32 mm x H40 mm x L90.3 mmW32 mm x H40 mm x L60.4 mmW32 mm x H40 mm x L92.7 mm
WeightApprox. 95 gApprox. 115 gApprox. 95 gApprox. 115 g
Standard accessoriesInstruction manual, mounting metal fitting,
power/output cable (2 m),
installation gauge
Instruction manual, mounting metal fitting, power/output cable (2 m)

*1. The default setting at shipment is 0 to +500°C. When using in the range of -50°C to +500°C or -50°C to +1,000°C, the range must be changed using ES1-TOOLS.
*2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2). In that case, the measurement error will be ±10°C.

 

ES1B

ItemsPart number
ES1B
Power supply voltage12 V DC, 24 V DC
Allowable power supply voltage fluctuation90–110% of the power supply voltage
Current Consumption20 mA or less
Measurement Temperature Range10–70°C, 60–120°C, 115–165°C, 140–260°C
Accuracy*1±5°C*2±2%PV or ±2°C, whichever is greater
±10°C*2±4%PV or ±4°C, whichever is greater
±30°C*2±6%PV or ±6°C, whichever is greater
±40°C*2+/-8%PV or +/-8°C, whichever is greater
Repeatability±1%PV or ±1°C, whichever is greater
Temperature drift0.4°C/°C or less
Effects of Electromagnetic InterferenceElectric Field Strength Noise ImmunityWithin +/-10°C (80-800MHz)
Within +/-30°C (800-1000MHz)
Conducted Disturbance Noise ImmunityWithin +/-10°C
Measurement Distance: Field of View Diameter1:1 typ.
Measurement wavelength6.5 to 14.0 μm
Light receiving elementThermopile
Response SpeedApproximately 300 ms for 63% response
Output Impedance1 to 4 kΩ
Operating temperature range-25 to +70°C (no condensation or freezing)
Permissible ambient humidityRelative humidity 35 to 85%
Vibration resistance (endurance)98 m/s2 10 to 55 Hz (X, Y, Z directions for 2 hours each)
Impact Resistance (Endurance)300 m/s2 in Each X, Y, Z Direction 3 times
Main Body MaterialABS Resin
Protective structureIP65
Applicable standardsCE marking*3
WeightApprox. 120 g
LeadCompensating cable 3 m
PVC insulation, heat resistant up to 70°C

*1. When using K thermocouple characteristics and an emissivity of 0.98
*2. Temperature change from any reference temperature of the measurement target
    Example: When corrected with 50°C as the reference temperature,
        at 55°C, the accuracy is the greater of ±2% PV or ±2°C,
        at 60°C, the accuracy is the greater of ±4% PV or ±4°C.
*3. EN61326-1: industrial electromagnetic environment (EN/IEC61326-1 Table 2)

 

ES1C

ItemsPart number
ES1C
Power supply voltageDC12-24V
Allowable Voltage Fluctuation Range90% to 110% of rated voltage
Current Consumption70 mA or less
Measurement Temperature Range0 to 400°C
Measuring Accuracy0–200°C: ±2°C 201–400°C: ±1% PV (emissivity 0.95)
Effects of Electromagnetic InterferenceElectric Field Strength Noise Immunity±10°C max
Conducted Disturbance Noise Immunity±10°C max
Response time100 ms/90%
Repeatability±1% of the reading
Measurement wavelength8 to 14 μm
Light receiving elementThermopile
Reflection Rate0.95 fixing
Current outputDC 4–20 mA, load 250 Ω or less
Ambient temperature rangeDuring use: 0 to +70°C, during storage: -20 to +70°C (No freezing or condensation)
Ambient humidity rangeDuring use/storage: relative humidity 35–85%
Vibration resistance (endurance)10 to 55 Hz, amplitude 1.5 mm, 2 hr in each direction of X, Y, and Z
Weight180 g
Protective structureEquivalent to IP67
Applicable standardsCE marking*

*EN61326-1: industrial electromagnetic environment (EN/IEC61326-1 Table 2)

Parts List

No.Name
(1)Lens
(2)Screw Hole for Mounting Metal Fitting
(3)Tripod Screw Hole
(4)Power output connector
(5)Micro USB connector
(6)Laser output port
(7)Laser Switch
(8)Mounting gauge mounting hole
Part Number
ES1-LP3-N
ES1-LP10-N
ES1-LW50-N
ES1-LW50L-N
ES1-LW100-N
ES1B 10-70C
ES1B 60-120C
ES1B 115-165C
ES1B 140-260C
ES1C-A40
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOperating Environment Operating Temperature Range
(°C)
Number of Elements Attaching Portion Shape Lead Wire Length F
(m)
Sensor Shape Lead Wire Length
(m)
Terminal Shape Lead Wire Coating Material Measurement temperature range
(°C)
Specification Mounting part shape

MYR 4,098.71

1 Piece(s) 9 Day(s) or more Standard0~55-Connector2-2---50~500Without aiming laserConnector

MYR 4,098.71

1 Piece(s) 9 Day(s) or more Standard0~55-Connector2-2---50~500Without aiming laser-

MYR 3,376.02

1 Piece(s) 9 Day(s) or more Standard0~55-Connector2-2---50~500Without aiming laserConnector

MYR 3,710.41

1 Piece(s) 9 Day(s) or more Standard0~55-Connector2-2---50~500With aiming laserConnector

MYR 4,381.46

1 Piece(s) 9 Day(s) or more Standard0~55-Connector2-2---50~1000Without aiming laserConnector

MYR 1,427.00

1 Piece(s) 5 Day(s) or more Heat Resistant-25~701With Screw3Without Sheath or Protective Sleeve3Lead wire straight type / without crimp terminalVinyl10~70--

MYR 1,427.00

1 Piece(s) 9 Day(s) or more Heat Resistant-25~701With Screw3Without Sheath or Protective Sleeve3Lead wire straight type / without crimp terminalVinyl60~120--

MYR 1,427.00

1 Piece(s) 9 Day(s) or more Heat Resistant-25~701With Screw3Without Sheath or Protective Sleeve3Lead wire straight type / without crimp terminalVinyl115~165--

MYR 1,427.00

1 Piece(s) 5 Day(s) or more Heat Resistant-25~701With Screw3Without Sheath or Protective Sleeve3Lead wire straight type / without crimp terminalVinyl140~260--

MYR 2,483.00

1 Piece(s) 5 Day(s) or more Heat Resistant / Water Proofing0~701With Screw2Without Sheath or Protective Sleeve2Lead wire straight type / without crimp terminal-0~400--

Loading...

  1. 1
 

Basic Information

Measurement Object Temperature Type Other Temperature Sensor Operating Humidity Range(%) 35::85
Power Supply Voltage(V) DC12~24

Additional Products in this Category

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)