(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Our website upgrade are completed! Latest improvements are now LIVE to enhance your ordering experience. You may be logged out due to the update. Please take note to login again or reset credentials if needed. More details here. 

Small Solenoid Lock / Safety Door Switch [D4SL-N] (D4SL-N4CFG)

Small Solenoid Lock / Safety Door Switch [D4SL-N] D4SL-N4CFG

Click this image to zoom it.

Move the mouse over the image to zoom

General-purpose enclosed switch with high shut-off capacity and high durability
[Features]
· ZE, ZV, and ZV2 types have built-in Z type general-purpose basic switch.
· Highly durable and has a large shutoff capacity.
· There are three types of mounting methods: side, bottom and side diagonal, as well as abundant actuator types.
· Connecting is easy since the terminal of the built-in switch is on the front when the cover is removed.
· Models with ground terminals support CE Marking.
· UL/CSA/CCC certified (contact the manufacturer for the certification format).

PDF

Part Number

Configured Part Number is shown.

D4SL-N4CFG

Drawing

Model D4SL-N****-*N (connector type)

Compact Electromagnetic Lock Safety Door Switch D4SL-N Model D4SL-N****-*N (Connector Type) External Shape

*If you insert a pin or similar protruding shape into the ⌀4.5 hole for fixing, you can mount it more securely.  

Model D4SL-N****-* (Terminal Block Type)

Compact Electromagnetic Lock Safety Door Switch D4SL-N Model D4SL-N****-* (Terminal Block Type) External Shape

*If you insert a pin or similar protruding shape into the ⌀4.5 hole for fixing, you can mount it more securely.  

Product Specification

Performance

Interlock typeType 2 (EN ISO 14119)
Encoding levelLow level coded (EN ISO 14119)
Protective structureIP67 *1
TYPE 4X Indoor use only (UL, CSA)
Durability*2MechanicalMore than 1 million times
ElectricalMore than 150,000 times
(at 125 V AC 1 A resistive load) *3
Allowable operation speed0.05 to 1 m/s
Allowable operation frequency4, 5 contact type: 30 times/min
6 contact type: 5 times/min
Direct opening force*4Minimum 60 N (EN60947-5-1)
Direct opening stroke*4Minimum 15 mm (EN60947-5-1)
Lock strength (Fzh) *5Minimum {1300} N
Contact resistance200 mΩ or less
Minimum applicable load*65 V DC 1 mA resistive load (N-level reference value)
Rated insulation voltage (Ui)150 V (EN60947-5-1)
Rated frequency50/60 Hz
Appliance ClassClass II (double insulation)
Pollution degree (operating environment)Pollution degree 3 (EN60947-5-1)
Impulse
Withstand voltage (Uimp)
(EN60947-5-1)
Between terminals of the same polarity1.5 kV
Between different pole terminals1.5 kV
Between each terminal and non-current-carrying metal part2.5 kV
Insulation resistance100 MΩ or more (500 V DC insulation resistance tester)
VibrationMalfunction10 to 55 Hz half amplitude 0.35 mm
ImpactMalfunction80 m/s2 or more
Endurance1000 m/s2 or more
Conditional short circuit current100 A (EN60947-5-1)
Rated contact current (Ith)2.5 A (11-42, 21-52, 21-22) 1 A  (others)
Operating ambient temperature-10 to 55℃ (no freezing)
Operating Ambient Humidity95% RH or less
WeightResin head
Approx. 290 g (connector type)
Approx. 330 g (terminal block type)
Metal head
Approx. 370 g (connector type)
Approx. 410 g (terminal block type)

*1. The values given above are initial values.
2. The switch contacts can be used for both general and micro loads; however, once a contact has switched a load, it cannot be used with a load of smaller capacity.
The contact surface may become rough, which could compromise contact reliability.
*1. This protective structure is based on test methods according to the standard (EN60947-5-1). Please confirm the sealing performance in advance under the actual operating environment and usage conditions.
The switch box body is protected against the ingress of dust and water; however, please use it in a location where chips, oil, water, or chemicals will not come into contact with the operation key insertion opening of the head section.
Otherwise, it may cause early wear, damage, or malfunction.
*2. The durability conditions are based on an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH. For other detailed conditions, please contact the manufacturer.
*3. Do not apply 125 V AC 1 A to more than three circuits.
*4. Be sure to secure it to ensure safe use.
*5. Based on the evaluation method of ISO 14119.
*6. This value may vary depending on switching frequency, environmental conditions, and reliability level. Please check with the actual load in advance.

Structure

Model D4SL-N****-D*N connector type
Model D4SL-N****-D* terminal block type
Compact Electromagnetic Lock Safety Door Switch D4SL-N Model D4SL-N****-D*N Connector Type Structural Drawing
Compact Electromagnetic Lock Safety Door Switch D4SL-N Model D4SL-N****-D* Terminal Block Type Structural Drawing

*If you insert a pin or similar protruding shape into the ⌀4.5 hole for fixing, you can mount it more securely.

Specifications Table

Model D4SL-N****-*N (connector type)

Model D4SL-N****-* (Terminal Block Type)

Operating CharacteristicsModel D4SL-N***-***N
Operation Key Insertion Force
Operation Key Withdrawal Force
Max 15N
Max 30N
Movement Until OperationMax 15mm
Movement Until Mechanical LockMin 3mm
Operating CharacteristicsModel D4SL-N****-*
Operation Key Insertion Force
Operation Key Withdrawal Force
Max 15N
Max 30N
Movement Until OperationMax 15mm
Movement Until Mechanical LockMin 3mm
Part Number
D4SL-N4CFG
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipDetector Shape Main Body Size Environment Acquired Standards Protection Structure Force Required for Push Side O.F.
(N)
Motion to Switching P.T.
(mm)
Contact Type Mechanical Life
(10,000 times)
Mechanical Operation Frequency
(times/min or Less)
Rated Operating Voltage
(V)
Rated Conductance Current
(A)
Main Body External Dimension, Width W
(mm)
Main Body External Dimension, Height H
(mm)
Main Body External Dimension, Length L
(mm)
Indicator Light Conduit Size Specification of Terminal Cord / cable pull-out direction (method) Details Type Mounting System Contact format Release Key Type Lock / Release System Operating key insertion direction Release Key Position Built-in Switch Specification AC Rated Voltage DC Rated Voltage Head Material Door Switch Type Contact Configuration

MYR 647.20

1 Piece(s) 9 Day(s) or more [Others] Key-StandardUL / CE / GB(CCC) / CSAIP67---10030-----Not IncludedM20-Mechanical Release System4 Contact Type-2NC + 1NC / 1NO (Short circuit between door monitor and lock monitor)General type (metal)DC24V solenoid lock-General type (Metal)2NC+1NC/1NO (Short-circuit between door monitor and lock monitor)--ResinElectromagnetic lock door switchTerminal Block

Loading...

  1. 1
 

Basic Information

Operating Temperature Range(°C) -10::55

Please check the type/dimensions/specifications of the part D4SL-N4CFG in the Small Solenoid Lock / Safety Door Switch [D4SL-N] series.

Products like this...

Part Number
D4SL-N2AFG-N
D4SL-N2CFA
D4SL-N2CFA-N
D4SL-N4DFA
D4SL-N4DFA-N
D4SL-N4DFG
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipDetector Shape Main Body Size Environment Acquired Standards Protection Structure Force Required for Push Side O.F.
(N)
Motion to Switching P.T.
(mm)
Contact Type Mechanical Life
(10,000 times)
Mechanical Operation Frequency
(times/min or Less)
Rated Operating Voltage
(V)
Rated Conductance Current
(A)
Main Body External Dimension, Width W
(mm)
Main Body External Dimension, Height H
(mm)
Main Body External Dimension, Length L
(mm)
Indicator Light Conduit Size Specification of Terminal Cord / cable pull-out direction (method) Details Type Mounting System Contact format Release Key Type Lock / Release System Operating key insertion direction Release Key Position Built-in Switch Specification AC Rated Voltage DC Rated Voltage Head Material Door Switch Type Contact Configuration

MYR 520.03

1 Piece(s) 5 Day(s) or more ---RU / EN / CE / GB(CCC) / TUVIP67---10030-----Not IncludedG1/2----1NC / 1NO + 1NC / 1NO (short circuit between door monitor and lock monitor)General type (metal)24 V DC Solenoid Lock System / Mechanical Release System--1NC/1NO+1NC/1NO (Short-circuit between door monitor and lock monitor)120125ResinElectromagnetic lock door switch-

MYR 647.20

1 Piece(s) 5 Day(s) or more ---RU / EN / CE / GB(CCC) / TUVIP67---10030-----Not IncludedG1/2----2NC + 1NC / 1NO (Short circuit between door monitor and lock monitor)General type (metal)Mechanical Lock System / 24 V DC Solenoid Release Method--2NC+1NC/1NO (Short-circuit between door monitor and lock monitor)120125ResinElectromagnetic lock door switch-

MYR 596.43

1 Piece(s) 5 Day(s) or more ---RU / EN / CE / GB(CCC) / TUVIP67---10030-----Not IncludedG1/2----2NC + 1NC / 1NO (Short circuit between door monitor and lock monitor)General type (metal)Mechanical Lock System / 24 V DC Solenoid Release Method--2NC+1NC/1NO (Short-circuit between door monitor and lock monitor)120125ResinElectromagnetic lock door switch-

MYR 647.20

1 Piece(s) 5 Day(s) or more ---RU / EN / CE / GB(CCC) / TUVIP67---10030-----Not IncludedM20----2NC + 2NC (short circuit between door monitor and lock monitor)General type (metal)Mechanical Lock System / 24 V DC Solenoid Release Method--2NC + 2NC (Short-circuit between door monitor and lock monitor)120125ResinElectromagnetic lock door switch-

MYR 596.43

1 Piece(s) 5 Day(s) or more ---RU / EN / CE / GB(CCC) / TUVIP67---10030-----Not IncludedM20----2NC + 2NC (short circuit between door monitor and lock monitor)General type (metal)Mechanical Lock System / 24 V DC Solenoid Release Method--2NC + 2NC (Short-circuit between door monitor and lock monitor)120125ResinElectromagnetic lock door switch-

MYR 608.00

1 Piece(s) 5 Day(s) or more ---RU / EN / CE / GB(CCC) / TUVIP67---10030-----Not IncludedM20----2NC + 2NC (short circuit between door monitor and lock monitor)General type (metal)24 V DC Solenoid Lock System / Mechanical Release System--2NC + 2NC (Short-circuit between door monitor and lock monitor)120125ResinElectromagnetic lock door switch-

Additional Products in this Category

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)