(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Our website upgrade are completed! Latest improvements are now LIVE to enhance your ordering experience. You may be logged out due to the update. Please take note to login again or reset credentials if needed. More details here. 

Safety Limit Switch [D4B-*N] (D4B-4511N)

Safety Limit Switch [D4B-*N] D4B-4511N

Click this image to zoom it.

Move the mouse over the image to zoom

Robust safety limit switch with metallic housing.
Certified with direct opening mechanism for both slow action and snap action types.
[Features]
· Direct opening mechanism (only at NC contact side) that opens the contact when an abnormality occurs in contact welding, etc.
· Realized a safety lever setting by using a mechanism where the lever is interlocked with the operating position display board.
· Also equipped with proper operation zone display mechanism.
· Single-action switching between left and right operation directions.
· The sealing structure of the head is reinforced to improve sealing properties (TÜV: IEC IP67, UL: NEMA3, 4, 4X, 6P, 13).

(i)Caution

  • The product images are representative only. Specifications may vary by part number, including shape and color.

PDF

Part Number

Configured Part Number is shown.

D4B-4511N

Drawing

Safety limit switch D4B-*N external shape drawing-1
Safety limit switch D4B-*N external shape drawing-2

*The dimensional tolerance for the parts not specified in the drawings of each model above is +/- 0.4 mm.
*1. By reversing the set position indicator plate, the lever can be fixed in any desired position.
*2. Due to the mechanism, this is a general limit switch, not a safety limit switch.

Product Specification

Structure

Safety limit switch D4B-*N structural drawing

Performance

Protective structure*1IP67 (EN60947-5-1)
Durability*2MechanicalOver 30 million operations (snap action), over 10 million operations (slow action)
Electrical500,000 operations or more (250 V AC 10 A resistive load)
Allowable operation speed1 mm to 0.5 m/s
Allowable operation frequencyMechanical120 times/min
Electrical30 times/min
Contact resistance25 mΩ or less
Minimum applicable load*35 V DC 180 mA resistive load (N level reference value)
Rated insulation voltage (Ui)600 V (EN60947-5-1)
Rated frequency50/60 Hz
Appliance ClassClass I (with earth terminal)
Pollution degree (operating environment)Pollution degree 3 (EN60947-5-1)
Impulse withstand voltage
(EN60947-5-1)
Between terminals of the same polarity2.5 kV (snap action) / 4 kV (slow action)
Between different pole terminals4 kV (Slow action)
Between each terminal and earth4 kV
Insulation resistance100 MΩ or more between same pole terminals, and between terminals and non-live metal part (500 V DC, insulation resistance tester)
Contact gapMinimum 2 x 2 mm (slow action), minimum 2 x 0.5 mm (snap action)
VibrationMalfunction10 to 55 Hz, Half amplitude 0.75 mm
ImpactEndurance1,000 m/s2 or more
Malfunction300 m/s2 or more
Conditional short circuit current100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe)20 A (EN60947-5-1)
Operating ambient temperature-40 to +80°C (no freezing)
Operating Ambient Humidity95% RH or less
WeightApproximately 250 g

*1. The values given above are initial values.
   2. Depending on the model, the above contents may differ.
*1. This protective structure is based on test methods according to the standard (EN60947-5-1). Please confirm the sealing performance in advance under the actual operating environment and usage conditions.
*2. The durability conditions are based on an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH.
*3. This value may vary depending on the switching frequency, environmental conditions, and reliability level. Please check with the actual load in advance.

Part Number
D4B-4511N
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipDetector Shape Environment Plunger Shape Type Roller Lever Shape Type Lever Shape Type Acquired Standards Force Required for Push Side O.F.
(N)
Motion to Switching P.T.
(mm)
Angle to Switching P.T
(deg)
Max. Stroke T.T
(mm)
Max. Angle T.T
(deg)
Contact Type Mechanical Life
(10,000 times)
Rated Operating Voltage
(V)
Rated Conductance Current
(A)
Main Body External Dimension, Width W
(mm)
Main Body External Dimension, Height H
(mm)
Main Body External Dimension, Length L
(mm)
Lever Length R
(mm)
Detector Element Details Movement After the Operation OT
(mm)
Operating Position OP
(mm)
Conduit Size Specification of Terminal Details Type O.D. Mounting System Direction of Operation Roller Type Contact format Built-in Switch Specification AC Rated Voltage Note

MYR 322.01

1 Piece(s) 5 Day(s) or more Roller lever typeStandard---TUV / UL / C-UL / CE / GB(CCC) / CSA / EN------1000-10----Roller lever type (resin roller)--M20-1-conduit type-----1NC/1NO contact (slow-action)125 / 250 / 400-

Loading...

  1. 1
 

Basic Information

Main Body Size Standard Operating Temperature Range(°C) -40::80 Protection Structure IP67
Mechanical Operation Frequency(times/min or Less) 120 DC Rated Voltage 8 / 14 / 30 / 125 / 250

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)