Small Limit Switch [D4C] (Part Numbers)

Small Limit Switch [D4C]

Click this image to zoom it.

Move the mouse over the image to zoom

Compact limit switch excelling in compact size, thin and high seal properties.
[Features]
· Approved by EN (TÜV), UL, CSA, CCC standard. (ask your manufacturer for information on approved models)
· High sealing property compliant with IEC Standard IP67.
· The plunger has a seal packing, a diaphragm and the built-in switch has a protective cap and a triple seal structure.
· 3 m and 5 m cords are used as a standard. Series with cords certified by UL and CSA standards.
· Plunger type enables multiple mountings.
· A series of LED indicator lights (red) is made to facilitate confirmation during operation. (Lights up when not operating as a standard)
· VCTF oil-resistant cord type and pre-wired type products confirm with CE marking. (However this is applicable to the Standard type only)

(i)Caution

  • The product images are representative only. Specifications may vary by part number, including shape and color.

PDF

Drawing

D4C-**01

Small limit switch D4C D4C-**01 drawing

Product Specification

Performance

Protective StructureIP67
Durability*1Mechanical*3More than 10 million times
Electrical*2More than 200,000 times (125 V AC 5 A resistant load)
Allowable operation speed0.1 mm to 0.5 m/s (for plunger type)
1 mm to 1 m/s (for roller lever type)
Allowable operation frequencyMechanical120 times/min
Electrical30 times/min
Rated frequency50/60 Hz
Insulation resistance100 MΩ or more (500 V DC insulation resistance tester)
Contact resistance (initial value)250 mΩ or less (with a 2 m cord)
300 mΩ or less (with a 3 m cord)
400 mΩ or less (with a 5 m cord)
Withstand voltageBetween terminals of the same polarity1,000 V AC 50/60 Hz for 1 min
Between current-carrying metal parts and ground1,500 V AC 50/60 Hz for 1 min
Uimp 2.5 kV (EN60947-5-1)
Between each terminal and non-current-carrying metal part1,500 V AC 50/60 Hz for 1 min
Uimp 2.5 kV (EN60947-5-1)
Rated insulation voltage (Ui)300 V (EN60947-5-1) *5
Pollution degree (operating environment)3 (EN60947-5-1)
Short circuit protection device10 A fuse gI or gG (IEC60269)
Conditional short circuit current100 A (EN60947-5-1)
Conventional enclosed thermal current (I the)5 A, 4 A, 0.5 A (EN60947-5-1)
Appliance ClassClass I (with ground wire) *6
VibrationMalfunction10 to 55 Hz double amplitude 1.5 mm *4
Impact resistantEnduranceMax. 1,000 m/s2
MalfunctionMax. 500 m/s2 *4
Operating ambient temperature-10 to +70℃ (no freezing)
Operating ambient humidity35 to 95% RH
Weight (D4C-1202)Approximately 360 g (with 3 m VCTF)
Approximately 540 g (with 5 m VCTF)

*The values given above are initial values.
* 1. The durability values are based on an ambient temperature of 5 to 35℃ and an ambient humidity of 40 to 70% RH, but durability varies depending on the type of load and magnitude of current.
*2. More than 1 million times for pre-wired type. (DC specification switching current 0.1 A)
* 3. More than 500,000 times for weather resistance type.
* 4.Excluding plastic rod type.
* 5. 250 V for pre-wired type.
* 6. class III for pre-wired type

Structure

Small limit switch D4C structural drawing
Part Number
Part NumberMinimum order quantityVolume DiscountDays to ShipDetector Shape Environment Plunger Shape Type Boot Seal Roller Lever Shape Type Rod Shape Type Operating Temperature Range
(°C)
Acquired Standards Protection Structure Force Required for Push Side O.F.
(N)
Motion to Switching P.T.
(mm)
Angle to Switching P.T
(deg)
Max. Stroke T.T
(mm)
Max. Angle T.T
(deg)
Contact Type Mechanical Life
(10,000 times)
Mechanical Operation Frequency
(times/min or Less)
Rated Operating Voltage
(V)
Rated Conductance Current
(A)
Main Body External Dimension, Width W
(mm)
Main Body External Dimension, Height H
(mm)
Main Body External Dimension, Length L
(mm)
Lever Length R
(mm)
Cable Specifications Detector Element Details Indicator Light Movement After the Operation OT
(mm)
Operating Position OP
(mm)
Specification of Terminal Cord / Cable Length
(m)
Details Type O.D. Mounting System Roller Type Contact format Wiring Specifications AC Rated Voltage DC Rated Voltage AC Electrical Rating details DC Electrical Rating details Electrical Rating Note

Loading...

 

Basic Information

Main Body Size Small

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)