Compact limit switch excelling in compact size, thin and high seal properties.
[Features]
· Approved by EN (TÜV), UL, CSA, CCC standard. (ask your manufacturer for information on approved models)
· High sealing property compliant with IEC Standard IP67.
· The plunger has a seal packing, a diaphragm and the built-in switch has a protective cap and a triple seal structure.
· 3 m and 5 m cords are used as a standard. Series with cords certified by UL and CSA standards.
· Plunger type enables multiple mountings.
· A series of LED indicator lights (red) is made to facilitate confirmation during operation. (Lights up when not operating as a standard)
· VCTF oil-resistant cord type and pre-wired type products confirm with CE marking. (However this is applicable to the Standard type only)
Part Number
Configured Part Number is shown.

| Protective Structure | IP67 | |
|---|---|---|
| Durability*1 | Mechanical*3 | More than 10 million times |
| Electrical*2 | More than 200,000 times (125 V AC 5 A resistant load) | |
| Allowable operation speed | 0.1 mm to 0.5 m/s (for plunger type) 1 mm to 1 m/s (for roller lever type) | |
| Allowable operation frequency | Mechanical | 120 times/min |
| Electrical | 30 times/min | |
| Rated frequency | 50/60 Hz | |
| Insulation resistance | 100 MΩ or more (500 V DC insulation resistance tester) | |
| Contact resistance (initial value) | 250 mΩ or less (with a 2 m cord) 300 mΩ or less (with a 3 m cord) 400 mΩ or less (with a 5 m cord) | |
| Withstand voltage | Between terminals of the same polarity | 1,000 V AC 50/60 Hz for 1 min |
| Between current-carrying metal parts and ground | 1,500 V AC 50/60 Hz for 1 min Uimp 2.5 kV (EN60947-5-1) | |
| Between each terminal and non-current-carrying metal part | 1,500 V AC 50/60 Hz for 1 min Uimp 2.5 kV (EN60947-5-1) | |
| Rated insulation voltage (Ui) | 300 V (EN60947-5-1) *5 | |
| Pollution degree (operating environment) | 3 (EN60947-5-1) | |
| Short circuit protection device | 10 A fuse gI or gG (IEC60269) | |
| Conditional short circuit current | 100 A (EN60947-5-1) | |
| Conventional enclosed thermal current (I the) | 5 A, 4 A, 0.5 A (EN60947-5-1) | |
| Appliance Class | Class I (with ground wire) *6 | |
| Vibration | Malfunction | 10 to 55 Hz double amplitude 1.5 mm *4 |
| Impact resistant | Endurance | Max. 1,000 m/s2 |
| Malfunction | Max. 500 m/s2 *4 | |
| Operating ambient temperature | -10 to +70℃ (no freezing) | |
| Operating ambient humidity | 35 to 95% RH | |
| Weight (D4C-1202) | Approximately 360 g (with 3 m VCTF) Approximately 540 g (with 5 m VCTF) | |
*The values given above are initial values.
* 1. The durability values are based on an ambient temperature of 5 to 35℃ and an ambient humidity of 40 to 70% RH, but durability varies depending on the type of load and magnitude of current.
*2. More than 1 million times for pre-wired type. (DC specification switching current 0.1 A)
* 3. More than 500,000 times for weather resistance type.
* 4.Excluding plastic rod type.
* 5. 250 V for pre-wired type.
* 6. class III for pre-wired type

| Part Number |
|---|
| D4C-0050 |
| D4C-1229-P |
| D4C-1250 |
| D4C-1450 |
| D4C-1550 |
| D4C-1650 |
| D4C-3250 |
| D4C-3350 |
| D4C-4250 |
| D4C-4450 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Detector Shape | Environment | Plunger Shape Type | Boot Seal | Roller Lever Shape Type | Rod Shape Type | Operating Temperature Range (°C) | Acquired Standards | Protection Structure | Force Required for Push Side O.F. (N) | Motion to Switching P.T. (mm) | Angle to Switching P.T (deg) | Max. Stroke T.T (mm) | Max. Angle T.T (deg) | Contact Type | Mechanical Life (10,000 times) | Mechanical Operation Frequency (times/min or Less) | Rated Operating Voltage (V) | Rated Conductance Current (A) | Main Body External Dimension, Width W (mm) | Main Body External Dimension, Height H (mm) | Main Body External Dimension, Length L (mm) | Lever Length R (mm) | Cable Specifications | Detector Element Details | Indicator Light | Movement After the Operation OT (mm) | Operating Position OP (mm) | Specification of Terminal | Cord / Cable Length (m) | Details Type | O.D. | Mounting System | Roller Type | Contact format | Wiring Specifications | AC Rated Voltage | DC Rated Voltage | AC Electrical Rating details | DC Electrical Rating details | Electrical Rating | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 138.87 | 1 Piece(s) | 5 Day(s) or more | Rod Shape | Standard | - | - | - | [Spring + Resin Rod] Plastic Rod | -10~70 | TUV / EN | IP67 | 1.47 | - | 15 | - | - | Single Pole Double Throw | 1000 | 120 | - | - | 40 | 17.4 | 49 | - | - | Plastic rod type | No indicator light | - | - | Ground terminal (general load type) included | - | Nylon rod | φ3.2 | Front mounting | - | 1c | - | - | - | - | - | - | - | ||
MYR 245.66 | 1 Piece(s) | 5 Day(s) or more | Rod Shape | Standard / Weather Resistance | - | - | - | [Spring + Resin Rod] Plastic Rod | -10~70 | TUV / GB(CCC) / EN | IP67 | 5.69 | - | 25 | - | - | Single Pole Double Throw | 1000 | 120 | DC30V or Less / AC240/250V | 4 | 40 | 17.4 | 65 | - | VCTF Oil Resistance Code 3m (0.75mm2 4 core Finished Outer Diameter 7.6mm) | Variable rod lever type | No indicator light | - | - | Ground terminal (general load type) included | 3 | Stainless Steel Lever | φ3 × 160 | Front mounting | - | 1c | VCTF oil resistance cord | 250 | 30 | 250 V AC (5 A) | 30 V DC (4 A) | - | - | ||
MYR 202.18 | 1 Piece(s) | 5 Day(s) or more | Rod Shape | Standard | - | - | - | [Spring + Resin Rod] Plastic Rod | -10~70 | TUV / CE / GB(CCC) / EN | IP67 | 1.47 | - | 15 | - | - | Single Pole Double Throw | 1000 | 120 | DC30V or Less / AC240/250V | 4 | 40 | 17.4 | 73 | 80 | VCTF Oil Resistance Code 3m (0.75mm2 4 core Finished Outer Diameter 7.6mm) | Plastic rod type | No indicator light | - | - | Ground terminal (general load type) included | 3 | Nylon rod | φ3.2 | Front mounting | - | 1c | VCTF oil resistance cord | 250 | 30 | 250 V AC (5 A) | 30 V DC (4 A) | - | - | ||
MYR 194.46 | 1 Piece(s) | 5 Day(s) or more | Rod Shape | Standard | - | - | - | [Spring + Resin Rod] Plastic Rod | -10~70 | TUV / GB(CCC) / EN | IP67 | 1.47 | - | 15 | - | - | Single Pole Double Throw | 1000 | 120 | DC30V or Less / AC240/250V | 4 | 40 | 17.4 | 73 | 80 | VCTF3m (0.75mm2 4 core Finished Outer Diameter 7.6mm) | Plastic rod type | No indicator light | - | - | Ground terminal (general load type) included | 3 | Nylon rod | φ3.2 | Front mounting | - | 1c | VCTF | 250 | 30 | 250 V AC (5 A) | 30 V DC (4 A) | - | - | ||
MYR 204.31 | 1 Piece(s) | 5 Day(s) or more | Rod Shape | Standard | - | - | - | [Spring + Resin Rod] Plastic Rod | -10~70 | GB(CCC) | IP67 | - | - | - | - | - | - | 1000 | 120 | - | - | - | - | - | - | - | Plastic rod type | No indicator light | - | - | - | 5 | Standard type | - | - | - | - | VCTF | 250 | 30 | 250 V AC (5 A) | 30 V DC (4 A) | - | - | ||
MYR 244.00 | 1 Piece(s) | 5 Day(s) or more | Rod Shape | Standard | - | - | - | [Spring + Resin Rod] Plastic Rod | -10~70 | UL / GB(CCC) / CSA | IP67 | 1.47 | - | 15 | - | - | Single Pole Double Throw | 1000 | 120 | DC30V or Less / AC240/250V | 4 | 40 | 17.4 | 73 | 80 | SJT(O)3m(0.75mm2 4 Core 7.6mm Finishing External Diameter) | Plastic rod type | No indicator light | - | - | Ground terminal (general load type) included | 3 | Nylon rod | φ3.2 | Front mounting | - | 1c | SJT (O) | 250 | 30 | 250 V AC (5 A) | 30 V DC (4 A) | - | - | ||
MYR 282.36 | 1 Piece(s) | 5 Day(s) or more | Rod Shape | Standard | - | - | - | [Spring + Resin Rod] Plastic Rod | -10~70 | TUV / EN | IP67 | 1.47 | - | 15 | - | - | Single Pole Double Throw | 1000 | 120 | DC30V or Less | 4 | 40 | 17.4 | 73 | 80 | VCTF Oil Resistance Code 3m (0.75mm2 4 core Finished Outer Diameter 7.6mm) | Plastic rod type | LED With indicator light | - | - | Ground terminal included | 3 | Nylon rod | φ3.2 | Front mounting | - | 1c | VCTF oil resistance cord | - | 30 | - | 30 V DC (4 A) | - | - | ||
MYR 243.38 | 1 Piece(s) | 5 Day(s) or more | [Others] Flexible type | Standard | - | - | - | [Spring + Resin Rod] Plastic Rod | -10~70 | TUV / GB(CCC) | IP67 | 1.47 | - | 15 | - | - | - | 1000 | 120 | DC30V or Less | 4 A 30 VDC (with LED indicator) | - | - | - | - | - | Plastic Rod | LED With indicator light | - | - | - | 5 | General type | - | - | - | - | VCTF oil resistance cord | - | 30 | - | - | DC30V 4A | - | ||
MYR 200.45 | 1 Piece(s) | 5 Day(s) or more | Rod Shape | Standard | - | - | - | [Spring + Resin Rod] Plastic Rod | -10~70 | TUV / CE / GB(CCC) / EN | IP67 | - | - | - | - | - | - | 1000 | 120 | - | - | - | - | - | - | - | Plastic rod type | No indicator light | - | - | - | 3 | Standard type | - | - | - | - | VCTF oil resistance cord | 125 | 30 | 125 V AC (0.1 A) | 30 V DC (0.1 A) | - | - | ||
MYR 239.41 | 1 Piece(s) | 5 Day(s) or more | Rod Shape | Standard | - | - | - | [Spring + Resin Rod] Plastic Rod | -10~70 | - | IP67 | - | - | - | - | - | - | 1000 | 120 | - | - | - | - | - | - | - | Plastic rod type | No indicator light | - | - | - | 3 | Standard type | - | - | - | - | VCTF | 125 | 30 | 125 V AC (0.1 A) | 30 V DC (0.1 A) | - | - |
Loading...
| Main Body Size | Small |
|---|
![Small Limit Switch [D4CC]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/OMR1_221000559240.jpg?$product_recommend_b$)
![Two-Circuit Limit Switch [WL-N/WL]](http://content.misumi-ec.com/image/upload/t_product_recommend_b/v1/p/jp/product/series/221000559396/221000559396_20230801115836.jpg?$product_recommend_b$)
![Small Limit Switch [HL-5000]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/221000559453_001.jpg?$product_recommend_b$)
![Compact Sealed Switch [ZC-*55]](http://content.misumi-ec.com/image/upload/t_product_recommend_b/v1/p/jp/product/series/221000559419/221000559419_20230801115836.jpg?$product_recommend_b$)
![Small Safety Limit Switch [D4N]](http://content.misumi-ec.com/image/upload/t_product_recommend_b/v1/p/jp/product/series/221005138046/OMR1_221005138046_2_20230801115837.jpg?$product_recommend_b$)
![Small Safety Limit Switch [D4F]](http://content.misumi-ec.com/image/upload/t_product_recommend_b/v1/p/jp/product/series/221005138035/OMR1_221005138035_20230801115837.jpg?$product_recommend_b$)


![Safety Limit Switch [D4B-*N]](http://content.misumi-ec.com/image/upload/t_product_recommend_b/v1/p/jp/product/series/221005138091/OMR1_221005138091_1_20230801115837.jpg?$product_recommend_b$)
![Compact Enclosed Switch [SHL]](http://content.misumi-ec.com/image/upload/t_product_recommend_b/v1/p/jp/product/series/221000559341/OMR1_221000559341_20230801115836.jpg?$product_recommend_b$)
![Semi-Compact Sealed Switch [D4MC]](http://my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/OMR1_221000559273.jpg?$product_recommend_b$)
![Small Enclosed Switch [D4E-*N]](http://content.misumi-ec.com/image/upload/t_product_recommend_b/v1/p/jp/product/series/221000559262/OMR1_221000559262_20230801115836.jpg?$product_recommend_b$)
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy