| Model parameters | Series C40 | Series C41 |
| EA-DRVC40-400-L-R | EA-DRVC40-120-S2 | EA-DRVC40-400-S2-BR | EA-DRVC40-750-S2-BR | EA-DRVC41-200-S2-A | EA-DRVC41-200-L-R-B | EA-DRVC41-200-S2-R-B | EA-DRVC41-400-S2-R-B |
| Rated input voltage | 24V/48V | AC220V (±20%) | AC220V/50HZ | DC24V-DC48V | AC220V/50HZ | DC24V-DC48V |
| Output current | (ms) Rated current | 15A (*1) | 1.4A | 2.8A | 4.3A | 2.5Arms | 7.5Arms | 1.2Arms | 15.0Arms |
| | (peak) Peak current | 42Ap | 4Ap | 8Ap | 12.2Ap | 8.0Ap | 22.5Ap | 4.0Ap | 45.0Ap |
| Energy consumption braking | External braking resistor, braking voltage set through software | No |
| Overvoltage alarm voltage | DC65V Above | DC390V Above | 125% Rated voltage overvoltage |
| Under voltage alarm voltage | DC18VBelow | DC200V Below | 70%Rated voltage overvoltage |
| Overload time | 2times overload, maximu duration of 0 seconds | 2 times overload, maximum duration of 10 seconds | 2 times overload, maximum duration of 15 seconds | - |
| Cooling method | Auxiliary heat dissipation, Free cooling | Free cooling | Forced air cooling | Free cooling, contact cooling |
| General function | Digital input | 5-way DI | 4-way DI | 4-way, supporting NPN/PNP, optocoupler input, high-level DC12V~DC30V, low-level DC0V~DC5V, input impedance 3K Ω |
| Digital input function | 20W: Two DI and one DO, DI1 enabled, DI2 reversed, DO fault output; 400W: forward and reverse rotation, forward and reverse jog, multi speed, self parking, fault reset, electronic brake, external fault input, forward and reverse rotation limit; | Forward running, reverse running, three-wire control, forward jogging, reverse jogging, free parking, fault reset, electronic braking, external fault input, forward limit, reverse limit, multi terminal speed selection, etc |
| Analog input function | Analog speed control | Analog speed control | Speed regulation, torque regulation |
| Digital output | 2-way DO | 2-way DO | 1 channel, optocoupler output, compatible with NPN/PNP support, maximum working voltage 60VDC, maximum output current 100mA |
| Protection function | Overcurrent, overload, short circuit, overtemperature, undervoltage, overvoltage, etc | Undervoltage protection, overvoltage protection, overload protection, hardware overcurrent protection, software overcurrent protection, current limiting protection, over temperature protection, phase loss protection, locked rotor protection, etc |
| Upper computer | Can use 485 communication to connect to computer upper computer software, set parameters, capture waveforms, and upgrade programs | Support |
| Bus control | Modbus/RS485 | Supports a maximum baud rate of 115.2K and can communicate with the controller using the Modbus RTU protocol | Supports a maximum baud rate of 115.2K and can communicate with the controller using the Modbus RTU protocol | Supports a maximum baud rate of 115.2K and can communicate with the controller using the Modbus RTU protocol |
| CAN open | No | No |
| Usage enviroment | Working temperature | Derating usage above 40 degrees Celsius | | -20~40℃, derated for use above 40℃. For every 1℃ increase, the rated current needs to be reduced by 2.5%. The maximum operating temperature can reach 50℃ |
| Storage temperature | -10℃~70℃ | -30 ℃~+60 ℃, with an air temperature change of less than 1℃/minute |
| Protection level | IP20 |
| Installation method | Vertical or horizontal installation | Built-in installation | Built-in installation | - |
| Height | When the working altitude is above 1000 meters and below 1000 meters, a derating of 1.5% is required for every 100 meters increase. The maximum working altitude is 4000 meters | Used below 1000 meters; For use with a derating of over 1000 meters, a derating of 1.5% is required for each 100 meter increase; Please test and confirm if the altitude is above 2000 meters |
| Pressure | 86kpa~106kpa | 86kpa~106kpa |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy